Skip to content

Feat/qualibration graph cross resonance#431

Open
HiroQM wants to merge 95 commits intomainfrom
feat/qualibration_graph-cross_resonance
Open

Feat/qualibration graph cross resonance#431
HiroQM wants to merge 95 commits intomainfrom
feat/qualibration_graph-cross_resonance

Conversation

@HiroQM
Copy link
Copy Markdown
Contributor

@HiroQM HiroQM commented Feb 5, 2026

This PR adds a set of calibration protocols for fixed-frequency Cross-Resonance (CR) gates under
calibrations/CrossResonance_calibrations_fixed_frequency. The scripts implement CR Rabi experiments with QST, followed by systematic Hamiltonian tomography for cr drive/cancellation drive optimizations.

Associated quam-builder PR: qua-platform/quam-builder#62

├── 30_CR_time_rabi_QST.py – Time-Rabi experiment with QST to extract CR Hamiltonian terms (IX, IY, IZ, ZX, ZY, ZZ).
├── 31a_CR_hamiltonian_tomography_vs_cr_drive_amp.py – CR Hamiltonian tomography as a function of CR drive amplitude
├── 31b_CR_hamiltonian_tomography_vs_cr_drive_phase.py – Drive phase optimization to maximize ZX while suppressing ZY.
├── 31c_CR_hamiltonian_tomography_vs_cr_cancel_phase.py – Cancellation pulse phase optimization to suppress unwanted IY terms.
├── 31d_CR_hamiltonian_tomography_vs_cr_cancel_amp.py – Cancellation pulse amplitude optimization via Hamiltonian tomography.
└── 31e_CR_correction_phase.py – Ramsey-based virtual-Z phase correction to cancel residual Z-type phases on control/target during the CR block.

@TheoLaudatQM TheoLaudatQM requested a review from OziEgri February 11, 2026 12:43
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment