4 changes: 4 additions & 0 deletions docs/TROUBLESHOOTING.md
Original file line number Diff line number Diff line change
Expand Up @@ -25,6 +25,10 @@ Some docks, adapters and DisplayLink-style outputs don't support DDC/CI. Check t
- Many monitors only use part of the 0–100 range. The per-monitor *Maximum volume* squeezes the scale below a limit, and *Volume curve* "Logarithmic" takes finer steps at low volume. Try it if the lowest levels are too loud or the top ones do nothing.
- If another computer or the monitor's own buttons left the volume above your limit, the next volume key press brings it back down to the limit.

## Brightness or volume stops short of the value I dragged to

Some monitors silently ignore a DDC command that comes too soon after the previous one. DisplayKnob keeps a short pause between commands, reads the value back once you stop, and if the last write was lost it sends it again and lengthens the pause for that monitor. What it learned is saved per monitor as `commandSpacingMs` in `settings.json` (delete the entry to learn again). If it still happens, attach the log: it lists every DDC command with its duration.

## The keyboard shortcuts don't work

- Use the **left** Alt key. The right one is AltGr on many keyboards and never triggers a shortcut, so it can't swallow the characters you type with it.
Expand Down
13 changes: 13 additions & 0 deletions src/DisplayKnob.App/Composition.cs
Original file line number Diff line number Diff line change
Expand Up @@ -4,6 +4,7 @@
using DisplayKnob.App.ViewModels;
using DisplayKnob.App.Views;
using DisplayKnob.Core;
using DisplayKnob.Core.Ddc;
using Microsoft.Extensions.DependencyInjection;
using Microsoft.UI.Dispatching;

Expand All @@ -20,6 +21,7 @@ public static ServiceProvider Build(Serilog.ILogger logger)

services.AddSingleton(logger);
services.AddDisplayKnobCore();
OverrideDdcSpacingIfRequested(services);
services.AddSingleton<UpdateService>();
services.AddSingleton<TrayIconHost>();
services.AddSingleton<StartupOffer>();
Expand All @@ -40,4 +42,15 @@ public static ServiceProvider Build(Serilog.ILogger logger)
ValidateScopes = true,
});
}

// Debug builds only: DISPLAYKNOB_DDC_SPACING_MS=<ms> starts every monitor with that pause between DDC commands,
// so "a too short pause is noticed and widened" can be tried on real hardware.
[System.Diagnostics.Conditional("DEBUG")]
private static void OverrideDdcSpacingIfRequested(IServiceCollection services)
{
if (int.TryParse(Environment.GetEnvironmentVariable("DISPLAYKNOB_DDC_SPACING_MS"), System.Globalization.CultureInfo.InvariantCulture, out var ms) && ms >= 0)
{
services.AddSingleton(DdcWorkerOptions.Default with { CommandSpacing = TimeSpan.FromMilliseconds(ms) });
}
}
}
259 changes: 253 additions & 6 deletions src/DisplayKnob.Core/Ddc/DdcWorker.cs
Original file line number Diff line number Diff line change
Expand Up @@ -12,6 +12,8 @@ namespace DisplayKnob.Core.Ddc;
/// observes every write requested before it.</para>
/// <para>Failed operations are retried with linear backoff; failures after the last attempt are
/// logged and reported as <see langword="null"/>/<see langword="false"/>, never thrown.</para>
/// <para>Commands are spaced (<see cref="DdcWorkerOptions.CommandSpacing"/>): a monitor drops a command that
/// follows the previous one too closely, and the call still reports success.</para>
/// </remarks>
public sealed class DdcWorker : IAsyncDisposable
{
Expand All @@ -27,11 +29,27 @@ public sealed class DdcWorker : IAsyncDisposable
private readonly CancellationTokenSource _stop = new();
private readonly Task _loop;
private bool _failing; // Only touched by the loop.
private long? _lastCommandEnd; // Only touched by the loop: when the previous DDC command finished.
private long _spacingTicks; // Written by the loop only; read from anywhere through CommandSpacing.

// Write verification (see DdcWorkerOptions.VerifiedCodes). All of it is only touched by the loop.
private readonly Dictionary<byte, uint> _lastKnown = []; // Last value seen or written per verified code.
private readonly Dictionary<byte, WriteCheck> _toVerify = [];
private readonly Dictionary<byte, int> _oddMismatches = [];
private readonly HashSet<byte> _notVerified = [];

/// <summary>
/// Creates the worker and starts its loop. The worker takes ownership of <paramref name="monitor"/>.
/// </summary>
public DdcWorker(IMonitorController monitor, TimeProvider timeProvider, DdcWorkerOptions options, ILogger logger)
/// <param name="monitor">The monitor to talk to.</param>
/// <param name="timeProvider">Clock for the spacing, retries and verification.</param>
/// <param name="options">Retry, pacing and verification policy.</param>
/// <param name="logger">Logger.</param>
/// <param name="initialSpacing">
/// The command spacing learned for this monitor earlier, if any. It is used when it is longer than
/// <see cref="DdcWorkerOptions.CommandSpacing"/>.
/// </param>
public DdcWorker(IMonitorController monitor, TimeProvider timeProvider, DdcWorkerOptions options, ILogger logger, TimeSpan? initialSpacing = null)
{
ArgumentNullException.ThrowIfNull(monitor);
ArgumentNullException.ThrowIfNull(timeProvider);
Expand All @@ -43,9 +61,15 @@ public DdcWorker(IMonitorController monitor, TimeProvider timeProvider, DdcWorke
_timeProvider = timeProvider;
_options = options;
_logger = logger.ForContext<DdcWorker>();
_spacingTicks = (initialSpacing is { } learned && learned > options.CommandSpacing ? learned : options.CommandSpacing).Ticks;
_loop = Task.Run(() => RunAsync(_stop.Token));
}

/// <summary>What the worker expects a verified code to read after its last write.</summary>
/// <param name="Expected">The value last written.</param>
/// <param name="Previous">The value the monitor held before it, if known: what it still reports if the write was dropped.</param>
private readonly record struct WriteCheck(uint Expected, uint? Previous);

private interface IReadItem
{
string Operation { get; }
Expand All @@ -65,6 +89,15 @@ private interface IReadItem
/// </summary>
public event EventHandler<VcpWriteFailedEventArgs>? WriteFailed;

/// <summary>
/// Raised on the worker's loop after it learned that this monitor needs a longer pause between commands; the
/// argument is the new spacing. Callers persist it so the next start doesn't have to find out again.
/// </summary>
public event EventHandler<TimeSpan>? CommandSpacingChanged;

/// <summary>The pause currently kept between DDC commands.</summary>
public TimeSpan CommandSpacing => TimeSpan.FromTicks(Volatile.Read(ref _spacingTicks));

/// <summary>Stable identity of the monitor.</summary>
public MonitorIdentity Identity => _monitor.Identity;

Expand Down Expand Up @@ -95,7 +128,20 @@ public void WriteVcp(byte code, uint value)
public Task<VcpValue?> ReadVcpAsync(byte code, CancellationToken cancellationToken = default) =>
EnqueueRead<VcpValue?>(
$"read VCP 0x{code:X2}",
m => m.TryGetVcp(code, out var value) ? (true, value) : (false, null),
m =>
{
if (!m.TryGetVcp(code, out var value))
{
return (false, null);
}

if (Verifies(code))
{
_lastKnown[code] = value.Current; // Runs on the loop, like every other use of the dictionary.
}

return (true, value);
},
cancellationToken);

/// <summary>
Expand Down Expand Up @@ -143,10 +189,33 @@ private async Task RunAsync(CancellationToken stopToken)
{
try
{
// One wait task is kept across iterations, so a signal that arrives while the loop is verifying isn't lost.
var signal = _signal.WaitAsync(stopToken);
while (true)
{
await _signal.WaitAsync(stopToken).ConfigureAwait(false);
await DrainAsync(stopToken).ConfigureAwait(false);
if (_toVerify.Count == 0)
{
await signal.ConfigureAwait(false);
signal = _signal.WaitAsync(stopToken);
await DrainAsync(stopToken).ConfigureAwait(false);
continue;
}

// Writes have just been sent. Once nothing new has come in for a while, check that the last one stuck.
using var quietCts = CancellationTokenSource.CreateLinkedTokenSource(stopToken);
var quiet = Task.Delay(_options.VerifyDelay, _timeProvider, quietCts.Token);
if (await Task.WhenAny(signal, quiet).ConfigureAwait(false) == signal)
{
await quietCts.CancelAsync().ConfigureAwait(false); // The wait for quiet starts over after the new work.
await signal.ConfigureAwait(false);
signal = _signal.WaitAsync(stopToken);
await DrainAsync(stopToken).ConfigureAwait(false);
}
else
{
await quiet.ConfigureAwait(false);
await VerifyAsync(stopToken).ConfigureAwait(false);
}
}
}
catch (OperationCanceledException) when (stopToken.IsCancellationRequested)
Expand Down Expand Up @@ -188,7 +257,11 @@ private async Task DrainAsync(CancellationToken stopToken)
foreach (var (code, value) in writes)
{
stopToken.ThrowIfCancellationRequested();
if (!await ExecuteWithRetryAsync($"write VCP 0x{code:X2}={value}", m => m.TrySetVcp(code, value), stopToken).ConfigureAwait(false))
if (await ExecuteWithRetryAsync($"write VCP 0x{code:X2}={value}", m => m.TrySetVcp(code, value), stopToken).ConfigureAwait(false))
{
TrackWrite(code, value);
}
else
{
WriteFailed?.Invoke(this, new VcpWriteFailedEventArgs(code, value));
}
Expand Down Expand Up @@ -223,7 +296,17 @@ private async Task<bool> ExecuteWithRetryAsync(string operation, Func<IMonitorCo
{
for (var i = 1; ; i++)
{
if (attempt(_monitor))
await WaitForCommandSpacingAsync(stopToken).ConfigureAwait(false);
var started = _timeProvider.GetTimestamp();
var succeeded = attempt(_monitor);
_lastCommandEnd = _timeProvider.GetTimestamp();
_logger.Debug(
"DDC {Operation} on {Monitor}: {Result} in {Elapsed:F0} ms",
operation,
DisplayName,
succeeded ? "ok" : "failed",
_timeProvider.GetElapsedTime(started, _lastCommandEnd.Value).TotalMilliseconds);
if (succeeded)
{
if (_failing)
{
Expand Down Expand Up @@ -254,6 +337,170 @@ private async Task<bool> ExecuteWithRetryAsync(string operation, Func<IMonitorCo
}
}

// See DdcWorkerOptions.CommandSpacing: a monitor ignores a command that comes too soon after the previous one.
private async Task WaitForCommandSpacingAsync(CancellationToken stopToken)
{
var spacing = CommandSpacing;
if (_lastCommandEnd is not { } last || spacing <= TimeSpan.Zero)
{
return;
}

var wait = spacing - _timeProvider.GetElapsedTime(last);
if (wait > TimeSpan.Zero)
{
await Task.Delay(wait, _timeProvider, stopToken).ConfigureAwait(false);
}
}

private bool Verifies(byte code) =>
_options.VerifyDelay > TimeSpan.Zero && _options.VerifiedCodes is { } codes && codes.Contains(code);

// A write went out: remember what the monitor should now report, and what it reported before.
private void TrackWrite(byte code, uint value)
{
if (!Verifies(code) || _notVerified.Contains(code))
{
return;
}

// If the previous write of this series was dropped, the monitor still reports the one before it.
uint? previous = _toVerify.TryGetValue(code, out var pending) ? pending.Expected
: _lastKnown.TryGetValue(code, out var known) ? known
: null;
_toVerify[code] = new WriteCheck(value, previous);
_lastKnown[code] = value;
}

// The writes have stopped: read back what was written last. Runs on the loop.
private async Task VerifyAsync(CancellationToken stopToken)
{
foreach (var (code, check) in _toVerify.ToArray())
{
lock (_lock)
{
if (_pendingWrites.ContainsKey(code))
{
continue; // A newer write is waiting; that one will be checked instead.
}
}

_toVerify.Remove(code);
await VerifyCodeAsync(code, check, stopToken).ConfigureAwait(false);

lock (_lock)
{
if (_pendingWrites.Count > 0 || _pendingReads.Count > 0)
{
return; // Real work came in; the rest is checked the next time it's quiet.
}
}
}
}

private async Task VerifyCodeAsync(byte code, WriteCheck check, CancellationToken stopToken)
{
var actual = await ReadBackAsync(code, stopToken).ConfigureAwait(false);
if (actual is null)
{
return; // The monitor isn't answering; the callers find out through their own reads and writes.
}

if (actual == check.Expected)
{
_oddMismatches.Remove(code);
return;
}

// A dropped write leaves the monitor at the value before it. Anything else (a monitor that rounds or clamps,
// or someone pressing its buttons) says nothing about timing, so the spacing is left alone.
if (check.Previous is { } previous && actual != previous)
{
var odd = _oddMismatches.GetValueOrDefault(code) + 1;
_oddMismatches[code] = odd;
if (odd >= 2)
{
_notVerified.Add(code);
_logger.Debug("{Monitor} reports other values than written for VCP 0x{Code:X2}; not verifying it any more", DisplayName, code);
}

return;
}

var startSpacing = CommandSpacing;
for (var attempt = 1; attempt <= MaxResends; attempt++)
{
GrowSpacing();
if (!await ExecuteWithRetryAsync($"re-send VCP 0x{code:X2}={check.Expected}", m => m.TrySetVcp(code, check.Expected), stopToken).ConfigureAwait(false))
{
SetSpacing(startSpacing);
return;
}

actual = await ReadBackAsync(code, stopToken).ConfigureAwait(false);
if (actual == check.Expected)
{
_oddMismatches.Remove(code);
_lastKnown[code] = check.Expected;
_logger.Information(
"{Monitor} ignored a DDC write sent {Start} ms after the previous command; keeping {Spacing} ms between commands",
DisplayName,
startSpacing.TotalMilliseconds,
CommandSpacing.TotalMilliseconds);
CommandSpacingChanged?.Invoke(this, CommandSpacing);
return;
}

if (actual is null)
{
SetSpacing(startSpacing);
return;
}
}

// A longer pause didn't help, so the pause isn't the problem: undo it and stop checking this code.
SetSpacing(startSpacing);
_notVerified.Add(code);
_logger.Warning("{Monitor} doesn't apply writes to VCP 0x{Code:X2} even after longer pauses", DisplayName, code);
}

private const int MaxResends = 3;

private async Task<uint?> ReadBackAsync(byte code, CancellationToken stopToken)
{
uint? value = null;
var ok = await ExecuteWithRetryAsync(
$"verify VCP 0x{code:X2}",
m =>
{
if (!m.TryGetVcp(code, out var read))
{
return false;
}

value = read.Current;
return true;
},
stopToken).ConfigureAwait(false);

if (ok && value is { } current)
{
_lastKnown[code] = current;
}

return ok ? value : null;
}

// Half again, at least 40 ms more, up to the limit: 80, 120, 180, 270, 400 ms.
private void GrowSpacing()
{
var current = CommandSpacing;
var next = current + TimeSpan.FromTicks(Math.Max(TimeSpan.FromMilliseconds(40).Ticks, current.Ticks / 2));
SetSpacing(next < _options.MaxCommandSpacing ? next : TimeSpan.FromTicks(Math.Max(current.Ticks, _options.MaxCommandSpacing.Ticks)));
}

private void SetSpacing(TimeSpan spacing) => Volatile.Write(ref _spacingTicks, spacing.Ticks);

private void CancelPendingReads()
{
IReadItem[] reads;
Expand Down