What and why

Some monitors silently ignore a DDC command that follows the previous one too closely, and the call still reports success. A quickly changed brightness or volume then stopped short of the target (for example, dragging to 100 left the monitor at 48).

The DDC worker now:

  • keeps a pause between commands (80 ms by default, growing to at most 400 ms),
  • reads brightness and volume back once writes stop,
  • resends a dropped write and lengthens the pause for that monitor,
  • saves the learned pause per monitor as commandSpacingMs in settings.json.

Debug builds accept DISPLAYKNOB_DDC_SPACING_MS to start with a given pause, to try the adaptation on real hardware. TROUBLESHOOTING.md describes the behavior.

Checklist

  • dotnet build has no warnings in DisplayKnob.Core and dotnet test passes (182 tests)
  • Docs updated (TROUBLESHOOTING.md)

Tested on hardware

Samsung S34C65xU. Quick slider changes now reach the target value.

…opped

Some monitors silently ignore a DDC command that follows the previous one
too closely, so a quickly changed brightness or volume stopped short of the
target value. The worker now keeps a pause between commands, reads brightness
and volume back once writes stop, resends a dropped write and lengthens the
pause for that monitor. The learned pause is saved per monitor as
commandSpacingMs.

Tested on a Samsung S34C65xU: quick slider changes now reach the target.
@muhep06
muhep06 merged commit b9eb5f8 into main Nov 11, 2026
1 check passed
@muhep06
muhep06 deleted the fix/ddc-command-spacing branch November 11, 2026 18:31
muhep06 added a commit that referenced this pull request Nov 11, 2026
The tests sent the second write as soon as the first one was seen. On a
slow runner the worker had already armed its "writes stopped" timer, so
the test moved the manual clock past the second write's spacing before
the worker looked at it. The monitor then never dropped the write,
nothing was learned and the test timed out after 10 s.

Hold the first write inside the fake monitor and queue the second one
behind it, so only the worker's own timers move the clock between them.

This was failing the CI run on `main` after #2 and on #3. Under the load
that used to fail it (6 parallel test processes, 5 runs each) it passed
30 of 30 locally.