fix: work the sustainable current from whichever ambient leaves less headroom - #33

Closed
zebraengine wants to merge 1 commit into
mainfrom
fix/sustainable-ambient-less-headroom
Closed

zebraengine wants to merge 1 commit into
mainfrom
fix/sustainable-ambient-less-headroom

Conversation

@zebraengine

Copy link
Copy Markdown
Owner

Problem

Two failures of the ambient behind sustainable_max_a, same evening, opposite directions:

  1. End of the 32 A probe (18:38): the trajectory-implied ambient named 47 A; the sensor's 30.25 °C named 44 A, which is what held. The current law extrapolated to 32 A over-reads the rise by ~2 °C, and the error comes back doubled when rescaled to 47 A. feat: fit how rise scales with current, and restore straight to the sustainable rate #31 fixed this by preferring the sensor.
  2. Restart at 20:38, 1.7 h after a 55-min charge: the sensor read 25.6 °C but the handle's trajectory implied 28.7 °C — the cable and wall were still heat-soaked. The sensor route named 48 A; the implied route (and suggested_max_a) named 46 A, which is right.

So "sensor first" is optimistic on a warm restart and "implied first" is optimistic after a low-current probe.

Code touched

  • wallmonitor/thermal.py predict(): sustainable_max_a is worked from whichever of the two ambients is warmer — i.e. leaves the handle less headroom. sustainable_ambient_source says which won ("measured" / "implied"). On model basis the implied ambient is the model's ambient, so nothing changes there. suggested_max_a untouched (implied, as before).
  • Docstring in sustainable_max_current, the amp-control module docstring, and docs/amp-control.md updated to describe the rule and both incidents.
  • tests/test_wallmonitor.py: sensor cooler than the trajectory implies → implied wins (42 A); sensor warmer → sensor wins (< 42 A). Existing trajectory test asserts sustainable_ambient_source == "implied" with no sensor.

Risk

Verification

  • uv run pytest: 153 passed (one new).
  • Both incidents replayed by hand against the rule: probe end → max(30.25, 27.3) = 30.25 → 44 A; warm restart → max(25.6, 28.7) = 28.7 → 46 A.

Deploy: pull + sudo systemctl restart wallmonitor.service. Server-only.

🤖 Generated with Claude Code

…headroom

Two failures of the sustainable-current ambient in one evening, in opposite
directions. At the end of the 32 A probe the trajectory-implied ambient
named 47 A where the sensor's 30.3 C named 44, which held: the current law
extrapolated to 32 A over-reads the rise, and the error comes back doubled
at 47. Preferring the sensor fixed that and was shipped in #31. Then the car
restarted 1.7 h after a 55 min charge: the sensor read 25.6 C, the handle
behaved like 28.7 C - the cable and wall were still warm - and the sensor
route named 48 A against a correct 46.

Neither source deserves to be first. The sensor reads the air, not the
hardware's thermal state; the trajectory reads the hardware, through a
model that is weakest far from the fits. So the sustainable current is
worked from whichever of the two leaves the handle less headroom. Both
incidents come out right: 44 A after the probe, 46 A on the warm restart.
On model basis the two coincide and nothing changes.

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
@zebraengine

Copy link
Copy Markdown
Owner Author

Superseded: the backtest in #34 shows every ambient-selection rule sits under a 3–5 °C model error that grows with ambient. The model gets an ambient term instead; the restore ambient gets re-evaluated with numbers after that.