- **Automatic derate prevention** — an optional daemon caps the vehicle's
charge current through a least-privilege BLE pairing when the forecast
firms up, and restores it once the risk clears
- **Degradation watch** — ambient-corrected heat-rise trend with confidence
intervals and a verified-baseline anchor, so "getting worse" is a
statistical claim, not a vibe
- **Degradation watch** — heat rise regressed on time while ambient and
charge current are held, over windows the charger was not regulating,
with confidence intervals and a verified-baseline anchor, so "getting
worse" is a statistical claim about the connector and not about the
weather
- **Actionable notifications, local-only** — browser push and LAN
webhook/self-hosted ntfy for phones, with a systemd + Docker deploy recipe
- Resilience: seamless restarts, downtime recorded as explicit gap events,
Expand Down
149 changes: 124 additions & 25 deletions docs/thermal-model.md
Original file line number Diff line number Diff line change
Expand Up @@ -58,6 +58,31 @@ itself.
The unit of thermal analysis is the **load window** — the stretch where
current actually flows.

## Free-running windows, and the ones the charger wrote

The other way a plateau can be fictitious is that the charger chose it. A
Gen 3 defends its own thermal limit long before alert 40: as the handle
warms it trims charge current back, and it can trim ~10 % without ever
leaving the fitter's steady-current band. The ramp then flattens *because
the current fell*, and the exponential reads that flattening as the
plateau — a lower rise paired with a faster τ, clearing every other gate
with an excellent RMSE.

That bias is not random. Foldback starts sooner in a hot garage, so the
under-read arrives and leaves with the weather; and a session that runs at
a low enough current never triggers it at all. Measured on one install:
windows whose current sagged fitted a median +33.3 °C rise where the same
charger's steady windows fitted +37.2 °C.

So every fit records `current_sag_a` — how far current fell from the head
of the window to its tail, compared by quarter-medians — and
`free_plateau`, true when that sag stayed inside 1.5 % of the window's
current. On the install above the two populations did not overlap: steady
windows sagged ≤ 0.6 %, regulated ones ≥ 3.9 %.

Regulated fits still describe what the handle actually did, so the
forecast keeps them. The degradation watch cannot use them at all.

## Ambient is a bracket, not a point

A single start-of-window ambient silently assumes the weather held still for
Expand Down Expand Up @@ -120,35 +145,77 @@ per-segment fit, and the drift verdict.
## Degradation watch

The same per-segment fits feed a trend. Rising heat at unchanged current
means added resistance — a loose lug, a degrading contact — so when recent
segments' fitted rise climbs past the baseline, the poller raises a monitor
alert and the Alerts page charts the fitted-rise trend.
means added resistance — a loose lug, a degrading contact — so when the
fitted rise climbs over time, the poller raises a monitor alert and the
Alerts page charts the fitted-rise trend.

### What it estimates, and why not a median split

The watch **regresses fitted rise on time** across the whole comparable
history, holding ambient and charge current, and reads the *time*
coefficient. The reported Δ is that slope times the observed span.

It did once compare a recent median against a baseline median, and that
asks the wrong question. "Are the last few fits higher?" is answered for
you by anything that moved with the calendar: a garage that cooled between
the two halves, or a vehicle capped to a lower current whose (48/I)²
normalization then lifts every recent fit at once. On one install the
split reported **+7.2 °C with a 95 % CI of [5.4, 9.1]** — "statistically
confirmed" — for a connector whose rise, regressed on time with ambient and
current held, was moving +0.01 ± 0.04 °C/day. The confidence was real. It
was confidence in the wrong estimand.

Regression fixes three things at once:

- **Confounders become covariates.** Ambient and charge current are
adjusted for instead of assumed away, and each one's coefficient is
reported so you can see what it was worth.
- **Every fit counts.** The estimate uses the whole history rather than
three fits against a handful, which is where the precision comes from.
- **Unseparable confounds declare themselves.** When a covariate cannot be
told apart from the calendar — a current cap applied once and kept is
nearly collinear with time — the collinearity inflates the slope's
standard error and the verdict declines to confirm. That is the honest
outcome, and it is reached automatically rather than by a rule someone
had to anticipate.

A covariate earns a column only when the history actually moved in it
(≥ 3 °C of ambient, ≥ 2 A of current); below that it buys nothing and
spends a degree of freedom. `/api/thermal` reports which columns were used
(`covariates`), each coefficient, the residual scatter, and any covariate
that correlated with time past 0.8 (`collinear_with_time`).

### What counts as drift

The alert needs two things at once: the recent-vs-baseline delta must be
**material** (≥ 2.5 °C — a confirmed 0.3 °C increase is real but not worth
an inspection) and **confirmed** — its 95% confidence interval, built from
this install's own session-to-session scatter, must clear zero. The
effective alert threshold is therefore the larger of the floor and what the
scatter demands, and the dashboard shows which one is binding. A noisy
install (variable ambient, a sensor in a draughty spot) must show more
before the watch alarms; a quiet one, less. A fixed 2.5 °C tripwire sat
near one sigma on a real install and fired on scatter alone.
The alert needs the change to be **material** (≥ 2.5 °C — a confirmed
0.3 °C increase is real but not worth an inspection), **confirmed** — the
slope's 95 % confidence interval, at a small-sample Student-t multiplier,
must clear zero — and **soundly measured** (see the ambient confound
below). The effective threshold is the larger of the floor and what this
install's own scatter demands, and the dashboard shows which one is
binding. A noisy install must show more before the watch alarms; a quiet
one, less.

A delta past the floor whose interval still straddles zero is a **lead**:
shown on the dashboard, pushed once at default priority, no alert row. More
sessions either confirm it or dissolve it.
A change past the floor that fails either of the other two tests is a
**lead**: shown on the dashboard, pushed once at default priority, no alert
row. More sessions either confirm it or dissolve it.

### What it compares

- **Only free-running fits.** Windows the charger was regulating are
excluded outright — their plateau is a setpoint, not an equilibrium.
`regulated_n` says how many sat out, and the Alerts page says so too,
because a verdict resting on four fits should not look like one resting
on twelve.
- **Only sessions near the install's recent operating current.** Cap the
vehicle at a new amperage and the watch follows, rather than judging
forever against a current the install no longer uses.
- **Pooled across a wider current band when the fits are clean.**
Ambient-bracketed fits are clean enough under the I² normalization to pool
in, so a baseline recorded at 48 A keeps judging charges after a cap to
40 A instead of the verdict going dark.
Ambient-bracketed fits join from a wider band, and the regression's own
current term then *adjusts* them: residual error in the I² normalization
lands on that coefficient instead of masquerading as a trend. On the
install above that coefficient read −0.99 °C per amp, which is the whole
of the phantom +7.2 °C.

### How sure it is

Expand All @@ -168,11 +235,43 @@ healthy", not "vs the first charges the monitor happened to see".

### The confounder the fits can't remove

A **rise-vs-ambient scatter** on the same page separates the one thing
left. Ambient is subtracted per fit, so a healthy install shows a flat cloud
regardless of garage temperature:

- a cloud **still sloping upward with ambient** exposes an environment
effect the model doesn't carry — multi-day heat soak of cable and
structure in an uninsulated garage;
The premise of `rise_ref` is that subtracting ambient leaves a number that
depends on the connector and not on the weather. The watch checks that
premise instead of assuming it: the regression's **ambient coefficient**
is how much rise still moves per degree of garage air after the
subtraction. A healthy install reads flat.

An install reading materially non-zero (≥ 0.3 °C/°C, resolved well enough
to be sure of the sign) has something in the measurement that the model
does not carry, and the watch says so and **caps its verdict at a lead** —
it can never raise an alert until the cause is found. Adjusting for a
confounder is not the same as understanding it.

The **rise-vs-ambient scatter** on the same page shows the shape:

- a cloud **sloping upward with ambient** exposes an environment effect —
multi-day heat soak of cable and structure in an uninsulated garage;
- a cloud **sloping downward** is the signature of a handle held at a
fixed temperature by something — most often charger regulation that the
free-plateau gate did not catch, since a hotter garage means the trim
starts sooner;
- an **elevated-but-flat** cloud is the genuine added-resistance signature.

### What the watch cannot do, and what to charge to fix it

Everything above measures a plateau the charger allowed. On an install
where full-rate charging always ends in foldback, the only free-running
windows are the low-current ones, and the watch is judging a handful of
fits at a current the install rarely uses.

The cheapest fix is a **fixed-condition probe**: once a month, charge at a
current low enough to run unregulated end to end (well under whatever
first triggers foldback), for at least 3 τ. That yields a plateau nobody
imposed, at a repeatable operating point, and comparing those month over
month is a degradation test with no extrapolation in it at all. A single
such charge is worth more to this watch than several at full rate.

Deliberately varying the current — 32 / 40 / 48 A inside one week, at
similar ambient — is worth doing once for a different reason: it breaks the
collinearity between current and the calendar, which is the one thing that
stops the regression from separating a cap from a trend.