Summary

On v0.5.0 (commit 354541eaa729a1c4bb6f35d4add46a95db4fbca4, Windows 10 19045.6466), an embedded (server-owned) OpenAI tunnel profile can go to terminal Failed because of a single transient error while writing readiness.json. The profile never recovers on its own; the only fix is restarting the owning Server.

Observed twice in one day on the same machine, ~5h40m apart:

{"schema_version":1,"service_pid":21872,"profile_revision":1,
 "tunnel_ready":false,"local_mcp_ready":false,
 "state":"failed","diagnostic":"tunnel_health_unavailable"}

At both moments the Server process itself was healthy: /healthz = 200, the same Server PID before and after, Runner connected=true / status=online, 39 projects visible, and the local MCP endpoint answering tools/list. Only the tunnel was dead.

Root cause

src/server_tunnels.rs treats a readiness persist error as fatal:

if persist_status(&profile, &status, index).is_err() {
    break Some("tunnel_health_unavailable".into());   // task ends, no retry
}

and per docs/architecture/server-owned-tunnels.md the supervisor deliberately does not restart a failed/uncertain tunnel task:

"It does not automatically restart a failed or uncertain task."

The persist path is a blocking wait-free exclusive lock:

  • crates/webcodex-environment/src/tunnel.rs write_tunnel_health_inner → fs2::FileExt::try_lock_exclusive(&file), and any error becomes SetupDiagnostic::io()
  • read_tunnel_health → fs2::FileExt::try_lock_shared(&file)

So any concurrent reader in another process (Desktop status polling, webcodex environment status / doctor, tunnel-diagnose, an AV scanner scanning the file) that holds the shared lock at that instant makes the exclusive attempt fail. Since the heartbeat runs roughly every 6 s (observed observed_at_ms deltas ≈ 6 s) and the freshness window is 7 s (now - time < 7000), the file is written thousands of times per day — a collision over a multi-hour session is practically inevitable.

#1029 fixed leaked locks inside the process (merged 2026-10-11, before this build); this report is about the legitimate cross-process shared-lock contention, which still takes the tunnel down permanently.

Environment / evidence

  • Install: Desktop app, persistent environment, single embedded profile, host_mode=embedded, autostart=true
  • Tunnel lifecycle is server-owned, so recovery commands refuse:
    • environment start tunnel --profile <id> → tunnel_host_transfer_required
    • environment restart tunnel --profile <id> → tunnel_server_owned ("This Tunnel lifecycle belongs to the Server. Control the owning Server")
  • Not an ACL / disk problem: readiness.json ACL is SYSTEM / Administrators / Administrator FullControl, owner is the signed-in user, file is a regular non-symlink file, ~56 GB free on the volume, archive attribute only
  • Not a network or credential problem: after a Server restart the same profile reaches state:"running", tunnel_ready:true, local_mcp_ready:true within seconds and keeps beating; control-plane reachability (chatgpt.com:443, api.openai.com:443) was fine before and after

Suggested fix

  1. Make the readiness persist resilient: retry try_lock_exclusive + write with a short bounded backoff (e.g. 3 attempts / 200 ms), and only escalate to Failed after N consecutive failures — do not tear the tunnel task down on the first error.
  2. Alternatively keep the last known-good readiness instead of forcing state: failed when the heartbeat write fails; a missed beat is not evidence that the tunnel is broken (the 7 s freshness window already expires on its own).
  3. Consider temp-file + atomic rename for readiness.json so readers never contend with the writer at all.

Impact

A ready tunnel silently becomes unusable (ChatGPT reports the tunnel client as absent) while every other component still reports healthy; nothing in the UI offers a retry, and the CLI refuses to operate the tunnel because it is server-owned. Users have to restart the whole Server task to recover, interrupting any in-flight session.

Activity

  1. swjnxyf commented on Nov 9, 2026

    @swjnxyf
    Collaborator

    Thanks for the detailed report and for helping us identify this Tunnel reliability issue.

    The fix has now been merged into main via #1411. We expect to publish a new release in the near future, but we don't have a confirmed release date yet.

    If you'd like to test the fix before the official release, you're welcome to build the latest main branch from source and share your experience or any additional feedback here. We recommend trying an unreleased build in a test environment first rather than replacing an active production deployment.

    We appreciate your contribution to improving WebCodex!