Skip to content

Keep GALEVO data when one cloud request fails - #12

Merged
wojciech-aniol merged 2 commits into
mainfrom
galevo-read-errors
Nov 23, 2026
Merged

wojciech-aniol merged 2 commits into
mainfrom
galevo-read-errors

Conversation

@wojciech-aniol

@wojciech-aniol wojciech-aniol commented Nov 23, 2026 •

Copy link
Copy Markdown
Owner

One failing cloud request no longer makes every entity unavailable. An empty energy sequence gives None, a menu items 500/550 keeps the last menu items, and a GALEVO data items 500 is asked again in smaller parts (at most 4 extra requests per read; after 2 failed reads in a row the parts are kept 1 hour per gateway). Menu values that are errors or probe limit values (3276.0, 3276.7, -3276.8, -3277.0) are None. Covers fustom integration issues #514, #520, #492 / #525 and the menu check from fustom/python-ariston-api#195.

Changes

  • _get_consumption_sequence_last_value: None when v is empty or missing (#514: IndexError at the first energy update).
  • GALEVO update_state / async_update_state: a menu ConnectionException with status 500 or 550 logs a warning and keeps the last menu items; other errors still raise. The data items are no longer lost with it (#520).
  • get_properties / async_get_properties (#492 / #525):
    • After a 500 for the full request (it is still retried once after 5 s, as before), the item list is asked in halves. A half that answers 500 is split again (never below 2 items).
    • At most 4 part requests per read (owner's choice); part requests are not retried. Parts not asked within the limit and parts that fail are left out, with a warning.
    • Answers are merged into one {"items": [...]}. If no part answers, the first error is raised and nothing is kept.
    • The parts are kept only after 2 reads in a row with a 500 for the full request; a full answer resets the count. Then the part count that worked is kept in a module dict per (api_url, gateway) for 1 hour (owner's choice), and the full request is tried again. One 500 (a short cloud problem) asks in parts only for that read, so a busy cloud does not get twice the requests for an hour.
    • Never on 429 or other 4xx: those raise at once, also from a part. No useCache: true retry (upstream fix: issue 525 and issue 26 fustom/python-ariston-api#193 / #196 sends up to ~25 requests per poll).
  • _get_menu_item_by_id: for value, None when error is true, the value is None, or the value is one of the limit values above. Other keys (unit, options) are returned as before.
  • New public helper error_status(error) in ariston_api.py (HTTP status of a ConnectionException, or None).

Notes for review

  • The plan named "value equal to max or to a negative min" as the menu check. I used the fixed set of limit values instead: the owner's Nimbus has an enum menu item with value 1.0 and max 1.0, which that check would drop. Upstream fustom#195 also moved to the fixed set ("preserve boundary menu values").
  • A real 0.0 is kept (#539 does not prove zeros are a cloud marker).
  • Request cost on a gateway that always fails: the full request (2 HTTP requests with the built-in retry) plus up to 4 parts per read. Without a 500 a read still sends exactly 1 request (test_properties_without_error_send_one_request).
  • With 4 part requests the smallest part is about a quarter of the list (~11 of 44 items). Gateways that answer only for 1–2 items (fustom#492 reports) may still fail; going smaller needs a higher limit.
  • When the menu request fails at the first poll after setup there are no old items, so the menu sensors are not added until a reload.

Tests

Each new test fails on main (checked by running the new tests against the main code), except the guards that must already pass: one request without an error, no split for 401/403/502, menu 401 raises, 0.0 kept.

  • tests/test_ariston_api.py: halves merged; one read with a 500 does not keep the parts (also fail, ok, fail); two reads in a row keep them for 1 hour, then the full request again; a failed half split again within 4 part requests with no part retry; all parts fail (first error raised, nothing kept); 401/429 in a part raises at once.
  • tests/test_galevo_device.py: empty / missing v; menu 500/550 keeps old items (sync and async), 401 and no-status errors raise; menu limit values, error: true, None give None.

192 tests pass, ruff clean.

🤖 Generated with Claude Code

One failing cloud request made every entity unavailable:
- an empty consumption sequence raised IndexError in the energy update;
- a 500 from the menu items request failed the whole state update,
  though the data items were fine;
- some gateways answer 500 to the full data items request but not to
  smaller parts, so every poll failed.

Now an empty sequence gives None, a menu 500 or 550 keeps the last menu
items, and a data items 500 is asked again in halves (split again on
500) with at most 4 part requests per read. The part count is kept for
an hour per gateway. A menu value that is an error or a probe limit
value (3276.0, 3276.7, -3276.8, -3277.0) is None.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@wojciech-aniol wojciech-aniol self-assigned this Nov 23, 2026
A single 500 can be a short cloud problem. Keeping the parts for an hour
after it doubled the requests per read for that hour, just when the
cloud was busy. Now one read with a 500 asks in parts only for itself;
the parts are kept after two reads in a row with a 500 for the full
request, and a full answer resets the count.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@wojciech-aniol
wojciech-aniol marked this pull request as ready for review November 23, 2026 10:06
@wojciech-aniol
wojciech-aniol merged commit 620a7d9 into main Nov 23, 2026
5 checks passed
@wojciech-aniol
wojciech-aniol deleted the galevo-read-errors branch November 23, 2026 10:06