OWFS/OWServer → MQTT bridge for 1-Wire devices
Version: 1.0.0
The project reads 1-Wire devices through the native OWServer protocol on TCP/4304 and publishes their values to MQTT. Discovery is based on devices exposed by OWServer; owalias.txt is used only to map ROM IDs to human-readable aliases. It does not scrape the OWFS HTTP interface.
- Native OWServer protocol via
pyownet - UTF-8
owalias.txt - Dynamic discovery through OWServer;
owalias.txtis optional for naming - DS18S20 / DS1822 / DS18B20 temperature devices
- DS2438
- DS2401
- DS1420
- DS2413 read support (
PIO_A/PIO_B) - JSON MQTT state topics
- Separate per-sensor availability topics
- Removed sensors remain represented in FHEM and are marked unavailable
- Bridge availability via MQTT LWT and OWServer connectivity state
- Flat/legacy MQTT mode
- ROM ID, alias and family in every JSON state
- special: Pressure calculation for the configured DS2438 (attached to an industrial transducer)
Default client ID:
ow2mqtt
Default root topic:
1-wire
JSON example:
1-wire/UG_Kesseltemperatur/state
Availability:
1-wire/UG_Kesseltemperatur/availability
Bridge availability:
1-wire/bridge/availability
{"alias":"UG_Kesseltemperatur","rom_id":"289435AF030000F2","family":"28","device_type":"DS18B20","available":true,"temperature":69.4375}The state topic always contains JSON in JSON mode; offline is never published to a state topic. A sensor that disappears from a successful OWServer discovery is not deleted; its availability is published as offline so FHEM keeps the device and marks it unavailable. Sensor availability is published separately as online or offline after the state message and is not retained. The bridge itself uses MQTT Last Will and Testament on retained 1-wire/bridge/availability.
Flat mode:
1-wire/UG_Kesseltemperatur/temperature
Select with:
MQTT_MODE=json
or:
MQTT_MODE=flat
The intended consumer is FHEM's MQTT_SERVER. JSON mode minimizes MQTT traffic and groups one sensor's state into one message. Flat mode is provided for installations where direct FHEM readings are preferred.
The MQTT payload remains FHEM-independent. To give automatically created
owfs_* devices a useful STATE, add the supplied
docs/fhem-stateformat.cfg once to the FHEM configuration.
It installs one notify which reacts to the device_type reading and sets
stateFormat only when no explicit stateFormat is already configured:
- DS18B20 / DS18S20 / DS1822 → temperature with 1 decimal place and
°C - DS2438 with alias
pressure→pressure bar - other DS2438 →
VDD V - DS2413 →
A: PIO_A | B: PIO_B - DS2401 / DS1420 →
available
Existing devices receive the setting with their next device_type event; new
devices are handled automatically after autocreate. Manually configured
stateFormat values are not overwritten.
For the FHEM bridge device ow2mqtt_bridge (CID/DEF ow2mqtt), the V3
bridge mapping should match both state and sensor availability, but not the
bridge's own availability topic:
attr ow2mqtt_bridge autocreate 1
attr ow2mqtt_bridge bridgeRegexp 1-wire/(?!bridge/)([A-Za-z0-9._-]+)/(state|availability):.* "owfs_$1"
For OW2MQTT, leave the autocreate attribute on MQTT2_SERVER unset so FHEM uses its default/simple mode. The generated owfs_<alias> device should then use json2nameValue($EVENT) without the state_ prefix. autocreate=complex is intentionally not used here because it generates a topic-derived prefix such as state_temperature. The availability topic follows the state and is non-retained, avoiding an availability-only first message during FHEM restart.
pyownet implements the OWServer protocol and is used as an external dependency. Its latest PyPI release is old, so Python-version compatibility should be verified when changing the base Python image or dependency set.
python -m pytestFor DS2413 software integration, OWServer can be run with the fake adapter (--fake=3A) on a separate test port; see docs/test-ds2413-fake.md.
The real OWServer should be tested with:
owdir -s <host>:4304 /
owread -s <host>:4304 /<alias>/temperaturebefore deploying the bridge.
The project code is intended to be released under GNU Affero General Public License v3.0.
Version 1.0.0 is the validated V3 release. It includes Docker log rotation, deployment hardening, dynamic discovery, sensor availability handling, and the FHEM integration documented below.
The bridge must be attached to the same Docker network as the existing
owfs container so that owfs:4304 resolves. The bridge does not need
USB access, privileged: true, or /dev/bus/usb.
The Compose file provides environment-variable overrides for deployment-specific settings. Public repository defaults are intentionally generic; set deployment-specific values in the environment before starting the container. In particular:
OW_SERVER_HOST
OW_SERVER_PORT
MQTT_HOST
MQTT_PORT
MQTT_CLIENT_ID
MQTT_ROOT_TOPIC
MQTT_MODE
POLL_INTERVAL
LOG_LEVEL
OWALIAS_FILE_HOST
config/config.yaml is included in the image as the baseline configuration;
environment variables take precedence. MQTT_HOST is required by the public
Compose file. The host-side owalias.txt path defaults to ./owalias.txt and can
be changed with OWALIAS_FILE_HOST without editing the Compose file.
For example, before starting the bridge, set the MQTT broker host explicitly:
export MQTT_HOST=<your-mqtt-broker-host-or-ip>
export OWALIAS_FILE_HOST=./owalias.txt
docker compose up -d --buildThe Docker container uses the json-file logging driver with log rotation:
logging:
driver: "json-file"
options:
max-size: "10m"
max-file: "3"This limits retained container logs to approximately 30 MB (three rotated files of up to 10 MB each). This setting applies to Docker's container logs; it does not change the application's log level or MQTT behavior.
The supplied compose file intentionally does not recreate the existing OWFS container. Verify the connection before deployment with:
owdir -s owfs:4304 /
owread -s owfs:4304 /UG_Kesseltemperatur/temperature
The bridge itself requires no FHEM-specific configuration beyond the MQTT connection. For the intended simple JSON autocreate setup:
- Keep
autocreateonMQTT_SERVERunset. - Define the bridge device with
autocreate 1and the V3bridgeRegexp. - Load
docs/fhem-stateformat.cfgonce. It creates theowfs2mqtt_stateFormatnotify. - Restart the bridge or wait for the next sensor update. FHEM creates
owfs_<alias>devices automatically. - If an alias is missing, the ROM ID is used in the device name.
The supplied state-format notify only adds stateFormat when a device has no
explicit value. Existing manual formatting therefore remains authoritative.
Example bridge definition:
define ow2mqtt_bridge MQTT2_DEVICE ow2mqtt
attr ow2mqtt_bridge IODev MQTT_SERVER
attr ow2mqtt_bridge autocreate 1
attr ow2mqtt_bridge bridgeRegexp 1-wire/(?!bridge/)([A-Za-z0-9._-]+)/(state|availability):.* "owfs_$1"
attr ow2mqtt_bridge stateFormat availability
Then load:
include docs/fhem-stateformat.cfg
owfs_* sensor devices are expected to contain the JSON readings directly
(temperature, VDD, pressure, PIO_A, PIO_B, available, etc.).
stateFormat affects only the displayed FHEM STATE, not the MQTT payload.
The public repository contains the application source, tests, documentation, Docker deployment files, and an example alias file.
Do not commit the site-specific owalias.txt, credentials, .env files, or
local deployment overrides. Use owalias.example.txt as the template for an
alias mapping.
Run:
pytest -qThe V3 release was validated with 15 automated tests plus end-to-end deployment testing on the target Photon (docker).