include customization to specify the modbus TCP id ports related with suport multiple inverters. #12
Posible drop box with inverters preconfig.
EMMA
Inverter.
o custom option. That can include things like.
Port ID
enable disable Connection Test
Connection Test String.
The hard-coded MODBUS_FIXED_ID / MODBUS_TEST_REG constants are gone. There is now a Test Target subsection inside Modbus TCP target, available both in the web settings page (/config) and in the initial Setup portal:
Device type drop-down with presets: EMMA, SUN2000 and Custom.
Connection check on boot: enable / disable. When disabled, the proxy opens the gateway as soon as the ping to the target IP succeeds (the ping step always stays).
The 4 fields of the test request:
Field
EMMA
SUN2000
Custom
Unit ID
0 (editable)
1 (editable)
free
Function code
03
03
free (1–127)
Start register
30000
30000
free
Register count
15
15
free
Selecting Custom shows a warning: the values are the user's responsibility.
How the check works
Ping to the target IP (retry every 30 s until it answers).
If enabled, the Modbus test request above is sent (retry every 10 s). It passes with any valid Modbus answer — the normal reply of that function, or its exception (FC | 0x80), which proves the device's Modbus stack is alive. No specific string is expected. With FC03/FC04 the text read is shown as the device model on the OLED and the dashboard.
Until both steps pass, incoming client connections are refused.
The configured Unit ID only affects the startup check and the menu diagnostics. Client requests are forwarded untouched with their own Unit ID, so a client can still talk to several devices (EMMA, inverters…) through the proxy.
Persistence
Settings are stored in NVS and survive reboots and USB/OTA flashing. When upgrading from 6.0-0 they don't exist yet and are initialised with the EMMA values (0 / FC03 / 30000 / 15, check enabled), so behaviour is unchanged until modified. /api/status exposes them (target_profile, startup_check, test_unit_id, test_function, test_register, test_reg_count).
Verified on the test proxy against the EMMA emulator.
Activity
mcamposv commentedon Nov 2, 2026
Implemented in #13 (firmware 6.1-0).
What was done
The hard-coded
MODBUS_FIXED_ID/MODBUS_TEST_REGconstants are gone. There is now a Test Target subsection inside Modbus TCP target, available both in the web settings page (/config) and in the initial Setup portal:EMMA,SUN2000andCustom.How the check works
FC | 0x80), which proves the device's Modbus stack is alive. No specific string is expected. With FC03/FC04 the text read is shown as the device model on the OLED and the dashboard.Until both steps pass, incoming client connections are refused.
The configured Unit ID only affects the startup check and the menu diagnostics. Client requests are forwarded untouched with their own Unit ID, so a client can still talk to several devices (EMMA, inverters…) through the proxy.
Persistence
Settings are stored in NVS and survive reboots and USB/OTA flashing. When upgrading from 6.0-0 they don't exist yet and are initialised with the EMMA values (
0 / FC03 / 30000 / 15, check enabled), so behaviour is unchanged until modified./api/statusexposes them (target_profile,startup_check,test_unit_id,test_function,test_register,test_reg_count).Verified on the test proxy against the EMMA emulator.