This capability represents a sounder, or strobe designed to alert a human to an emergency situation.
Alarm
Requests the device begin to alarm and inform a human about an emergency situation.
Options / Body
{
"AlarmType": <type of alarm>,
"Volume": <a floating point value between 0.0 and 1.0>,
"Visual": <true/false>,
"Duration": <duration of alarm in milliseconds>
}
The follow alarm types exist and may effect the alarm sound or behaviour.
General
Fire
Security
Environmental
Panic
Tamper
DeviceFault
HealthAlarm
Clear
Clear any existing alarm, silence and stop any visual indication.
No Options / Body
Alert
Requests the device perform a short alarm/alert to get the attention of a human.
Options / Body
{
"AlarmType": <type of alarm>,
"AlertType": <type of alert>,
"Volume": <a floating point value between 0.0 and 1.0>,
"Visual": <true/false>,
}
In addition to accepting an alarm type, an alert type must also be specified.