HVC intro notes before each motif; retrain - #18
Merged
Merged
Conversation
E fired at ~5 Hz through the first 60 ms of every motif (2.5 Hz later) because the HVC-driven inhibition only switches on at motif onset; a silent burn-in does not help. Two 80 ms introductory notes of HVC activity, no sound, 20 ms gaps (HVC_INTRO = (2, 80, 20)), now precede each motif in training, evaluation and the figures, passed to fit/transform as hvc_prelude so the returned spikes and every index stay motif-aligned. - Onset bump 4.96 -> 3.61 Hz (peak 11.9 -> 7.1 Hz); every DAF metric and the cancellation ratio are within their 10-seed noise. - The model's stimulus record carries hvc_intro; a model that records its stimuli but not intro notes is evaluated without them. - sven-train-ven / sven-evaluate / sven-figure: --hvc-intro NOTES MS GAP. - Retrained (pure-defaults run reproduces it byte-for-byte); slow-test pins and 3-SD tolerances, README table, MODEL.md and design notes updated. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Removes most of the start-of-motif transient.
Cause. E fired at ~5 Hz through the first 60 ms of every motif, against 2.5 Hz later, because the HVC-driven inhibition only switches on at motif onset: I fires at ~17 Hz in the first 30 ms vs 33 Hz later. A silent burn-in doesn't help, and the bump appears with HVC alone and no sound.
Change.
HVC_INTRO = (2, 80, 20)), precede each motif in training, evaluation and the figures.fit/transformashvc_prelude, so the returned spikes and every index stay aligned to the motif, and the figures show only the motif.--hvc-intro NOTES MS GAPonsven-train-ven,sven-evaluateandsven-figure. A model that records its stimuli but no intro notes is evaluated without them.Effect (retrained, 10 seeds):
Artifacts. Retrained
ven_model.npz, and a pure-defaults run reproduces it byte-for-byte;MANIFEST.sha256updated. The slow-test pins and 3-SD tolerances, the README table,MODEL.mdand the design notes are updated. 206 tests pass; ruff clean.finchsim. Its AIV pipeline builds its own HVC stub without intro notes, and is still pinned to the old model and commit, so it's unaffected until it next upgrades.