Solarmax Inverter Integration for Home Assistant

hacs_badge GitHub release GitHub license

A Home Assistant custom integration for Solarmax solar inverters. This integration allows you to monitor your Solarmax inverter's performance directly within Home Assistant.

⚠️ Compatibility Notice: This integration has been tested specifically on a Solarmax 7TP2 Inverter and should work with most Solarmax inverters built mainly before 2015. Compatibility with newer models is not guaranteed. Please test and report your results!

Features

  • Real-time monitoring of solar inverter data
  • Automatic discovery via config flow
  • Multiple sensor types including:
    • AC Power (PAC)
    • DC Power (PDC)
    • Energy production metrics
    • Inverter status and diagnostics
  • Configurable update intervals
  • Local polling - no cloud dependency required
  • UI reconfiguration support - modify settings without removing the integration
  • Advanced diagnostics with comprehensive device information
  • Smart sensor management - important sensors enabled, diagnostic sensors optional

Supported Devices

Tested Models

  • Solarmax 7TP2 Inverter ✅ Fully tested and confirmed working
  • Solarmax 4200S Inverter ✅ Confirmed working by user reports
  • Solarmax 3000S Inverter ✅ Confirmed working by user reports

Likely Compatible Models

  • Solarmax inverters manufactured mainly before 2015
  • Models using the MaxComm protocol over TCP/IP (port 12345)
  • Single-phase and three-phase models from the following series:
    • TP series (e.g. 4TP, 5TP2, 6TP2, 7TP2)
    • P series (e.g. 2000P, 3000P, 4000P, 5000P)
    • MT series (e.g. 10MT, 13MT3, 15MT3)
    • S series (e.g. 2000S, 3000S, 4200S, 6000S)
    • SP series (e.g. 1000SP, 2000SP, 3000SP)
    • SHT series (e.g. 20SHT, 30SHT, 50SHT, 60SHT)
    • TS-SV series
    • C/E series (older models: 2000C, 3000C, 4000C, 6000C)

Known Incompatible Models

  • Newer Solarmax models (2015+) that use different communication protocols
  • Models that only support Modbus RTU/TCP
  • Cloud-only models without local network access

Note: If you're unsure about compatibility, try the integration. It will fail gracefully if your model isn't supported.

Supported Functions

Sensors

The integration provides multiple sensor entities organized by importance:

Core Monitoring (Enabled by Default)

  • AC Power (PAC) - Current AC power output in Watts
  • DC Power (PDC) - Current DC power input in Watts
  • Energy Day (KDY) - Daily energy production in kWh
  • Energy Month (KMT) - Monthly energy production in kWh
  • Energy Year (KYR) - Yearly energy production in kWh
  • Energy Total (KT0) - Total lifetime energy production in kWh
  • Status Code (SYS) - Current inverter operational status (enum, ~110 states)
  • Alarm Codes (SAL) - Current alarm/error codes (bitmask)

Production History (Disabled by Default)

  • Energy Yesterday (KLD) - Previous day's energy production in kWh
  • Energy Last Month (KLM) - Previous month's energy production in kWh
  • Energy Last Year (KLY) - Previous year's energy production in kWh
  • Relative Power (PRL) - Current output as % of rated power

Diagnostic Sensors (Disabled by Default)

  • DC Power Strings (PD01, PD02, PD03) - Individual string power outputs
  • AC Voltage Phases (UL1, UL2, UL3) - Voltage per phase
  • DC Voltage (UDC) - Total DC input voltage
  • DC Voltage Strings (UD01, UD02, UD03) - Individual string voltages
  • AC Current Phases (IL1, IL2, IL3) - Current per phase
  • DC Current (IDC, ID01, ID02, ID03) - Total and individual string currents
  • Inverter Temperature (TKK, TK2, TK3) - Internal operating temperatures (up to 3 sensors)
  • Power On Hours (KHR) - Total operational hours
  • Startups (CAC) - Number of startup cycles
  • Installed Power (PIN) - Rated peak power of the inverter in Watts
  • Grid Frequency (TNF) - Current AC grid frequency in Hz
  • Grid Voltage Upper Limit (ULH) - Configured maximum grid voltage in V
  • Grid Voltage Lower Limit (ULL) - Configured minimum grid voltage in V
  • Grid Frequency Upper Limit (TNH) - Configured maximum grid frequency in Hz
  • Grid Frequency Lower Limit (TNL) - Configured minimum grid frequency in Hz

Note: Not all inverter models support all sensors. Keys not recognised by the inverter are silently omitted from the response — unsupported sensors will show as unavailable.

Platforms

  • Sensor Platform - All monitoring data
  • Diagnostics Platform - System diagnostic information
  • Config Flow - Easy setup and reconfiguration
  • Options Flow - Modify settings without re-adding

Installation

HACS (Recommended)

  1. Open HACS in your Home Assistant instance
  2. Go to "Integrations"
  3. Click the three dots in the top right corner
  4. Select "Custom repositories"
  5. Add this repository URL: https://github.com/oschick/solarmax-ha-integration
  6. Select "Integration" as the category
  7. Click "Add"
  8. Search for "Solarmax Inverter" and install it
  9. Restart Home Assistant

Manual Installation

  1. Download the latest release from the releases page
  2. Extract the contents
  3. Copy the custom_components/solarmax folder to your Home Assistant custom_components directory
  4. Restart Home Assistant

Configuration

The integration can be configured through the Home Assistant UI:

  1. Go to SettingsDevices & Services
  2. Click Add Integration
  3. Search for "Solarmax Inverter"
  4. Enter your inverter details:
    • Host: IP address of your inverter
    • Port: Communication port (default: 12345)
    • Update Interval: How often to poll data (default: 30 seconds)
    • Device Name: Friendly name for your inverter
    • Verify response checksum: Validate CRC on inverter responses (default: enabled)
    • Twilight elevation threshold: Sun elevation (degrees) below which the inverter is expected to be offline (default: 5)

Twilight Elevation Threshold

During dusk and dawn, the sun may technically be above the horizon while irradiance is still too low for the inverter to operate. The integration treats the inverter as expected to be offline while the sun's elevation is below this configurable threshold, avoiding false "unavailable" warnings during these twilight periods.

If your inverter starts up later or shuts down earlier relative to sunrise/sunset than expected, adjust this value (0-90 degrees) via Configure on the integration.

Checksum Verification

By default, the integration validates the CRC checksum on every response from the inverter to detect corrupted data. If you experience persistent "checksum verification failed" errors, your inverter may use a non-standard CRC implementation.

To disable checksum verification:

  1. Go to SettingsDevices & Services
  2. Find your Solarmax Inverter integration
  3. Click Configure
  4. Uncheck Verify response checksum
  5. Click Submit

Note: Disabling checksum verification means corrupted responses will not be detected. Only disable this if you are experiencing checksum errors and have verified that the data values are otherwise correct.

Reconfiguration

You can modify the integration settings without removing and re-adding:

  1. Go to SettingsDevices & Services
  2. Find your Solarmax Inverter integration
  3. Click Configure
  4. Update any settings and click Submit
  5. The integration will automatically reload with new settings

Data Update Information

The integration uses local polling via the MaxComm protocol to retrieve data from your inverter:

  • Protocol: MaxComm (proprietary SolarMax TCP protocol, documented August 2022)
  • Update Method: Direct TCP/IP connection to inverter (default port 12345)
  • Update Frequency: Configurable (default: 30 seconds)
  • Night Mode: Automatically detects when inverter is offline at night
  • Retry Logic: Smart retry with exponential backoff for connection failures
  • Connection Health: Tracks consecutive failures and connection statistics
  • Checksum Verification: Validates response CRC to detect corrupt data

MaxComm Protocol Overview

The MaxComm protocol is a Master-Slave TCP protocol used by SolarMax inverters:

  • Communication: Master-Slave (integration polls, inverter responds)
  • Data Encoding: All values transmitted as ASCII hex characters
  • Response Time: Typical 300ms, maximum timeout 3000ms
  • Addressing: Device addresses 1–249 (configurable on the inverter)
  • Error Detection: 4-character hex CRC checksum on every packet

Request/response format:

{<Src>;<Dest>;<Length>|<Port>:<Data>|<CRC>}

The integration queries all supported data keys in a single request. Keys not recognized by the inverter are simply omitted from the response (graceful degradation).

Update Process

  1. Integration connects to inverter via TCP socket (port 12345)
  2. Builds a MaxComm protocol request with all monitored data keys
  3. Receives and validates response (CRC checksum verification)
  4. Parses hex-encoded values and applies network variable scaling
  5. Handles errors gracefully (temporary network issues, night mode, etc.)
  6. Logs diagnostic information for troubleshooting

Use Cases

1. Energy Production Monitoring

Monitor your solar production in real-time and track daily, monthly, and yearly totals:

# Dashboard card example
type: entities
title: Solar Production
entities:
  - entity: sensor.solarmax_inverter_ac_power
    name: Current Power
  - entity: sensor.solarmax_inverter_energy_day
    name: Today's Production
  - entity: sensor.solarmax_inverter_energy_total
    name: Total Production

2. System Health Monitoring

Keep track of your inverter's operational status and detect issues early:

# Automation to alert on inverter alarms
automation:
  - alias: "Solar Inverter Alarm"
    trigger:
      - platform: state
        entity_id: sensor.solarmax_inverter_alarm_codes
        to: '!0'  # Any non-zero alarm code
    action:
      - service: notify.mobile_app
        data:
          message: "Solar inverter alarm: {{ states('sensor.solarmax_inverter_alarm_codes') }}"

3. Performance Analysis

Analyze inverter performance with detailed diagnostic data:

# Track inverter efficiency
sensor:
  - platform: template
    sensors:
      solar_efficiency:
        friendly_name: "Solar Efficiency"
        unit_of_measurement: "%"
        value_template: >
          {% set ac_power = states('sensor.solarmax_inverter_ac_power') | float %}
          {% set dc_power = states('sensor.solarmax_inverter_dc_power') | float %}
          {% if dc_power > 0 %}
            {{ ((ac_power / dc_power) * 100) | round(1) }}
          {% else %}
            0
          {% endif %}

4. Energy Management

Integrate with Home Assistant energy dashboard and automation:

# Energy dashboard configuration
sensor:
  - platform: integration
    source: sensor.solarmax_inverter_ac_power
    name: solar_energy_kwh
    unit_prefix: k
    round: 2
    method: left

Automation Examples

Daily Production Summary

automation:
  - alias: "Daily Solar Summary"
    trigger:
      - platform: time
        at: "20:00:00"
    action:
      - service: notify.family
        data:
          title: "Daily Solar Production"
          message: >
            Today's solar production: {{ states('sensor.solarmax_inverter_energy_day') }} Wh
            Total production: {{ states('sensor.solarmax_inverter_energy_total') }} kWh

Peak Power Alert

automation:
  - alias: "Peak Solar Power"
    trigger:
      - platform: numeric_state
        entity_id: sensor.solarmax_inverter_ac_power
        above: 5000  # Adjust threshold as needed
    action:
      - service: notify.mobile_app
        data:
          message: "Solar inverter producing {{ states('sensor.solarmax_inverter_ac_power') }}W!"

Maintenance Reminder

automation:
  - alias: "Solar Maintenance Reminder"
    trigger:
      - platform: numeric_state
        entity_id: sensor.solarmax_inverter_power_on_hours
        above: 8760  # One year of hours
    action:
      - service: notify.maintenance
        data:
          message: "Solar inverter has {{ states('sensor.solarmax_inverter_power_on_hours') }} operating hours. Consider maintenance check."

Known Limitations

Protocol Limitations

  • Single Device: Integration designed for one inverter per instance
  • MaxComm Only: Only supports the MaxComm protocol (mainly pre-2015 SolarMax devices)
  • TCP/IP Only: Requires network connection (no RS485/serial support)
  • Polling Only: No push notifications from inverter (MaxComm is Master-Slave)
  • Read-Only: Only data queries (port 100/0x64); settings commands (port 200/0xC8) not implemented

Network Requirements

  • Direct Access: Inverter must be accessible on local network
  • Port Availability: Default port 12345 must be open
  • Static IP Recommended: DHCP changes may require reconfiguration

Functional Limitations

  • No Control: Read-only integration (monitoring only, no inverter control)
  • No String Detection: Cannot auto-detect number of DC strings
  • Basic Diagnostics: Limited to data provided by inverter protocol
  • Night Mode: All sensors unavailable when inverter is offline at night

Performance Considerations

  • Update Frequency: Minimum recommended interval is 10 seconds
  • Network Impact: Each update requires TCP connection establishment
  • Memory Usage: Minimal, but stores recent connection history

Troubleshooting

Connection Issues

Problem: "Failed to connect to inverter"

Possible Causes:

  • Incorrect IP address or port
  • Network connectivity issues
  • Inverter is offline or in standby mode
  • Firewall blocking connection

Solutions:

  1. Verify inverter IP address and port in router/network settings
  2. Test network connectivity: ping <inverter_ip>
  3. Check if inverter is powered on and operational
  4. Temporarily disable firewall to test connection
  5. Try connecting from command line: telnet <inverter_ip> 12345

Problem: "Connection timeout"

Possible Causes:

  • Network latency or congestion
  • Inverter is busy or overloaded
  • Update interval too aggressive

Solutions:

  1. Increase update interval to 60+ seconds
  2. Check network quality and stability
  3. Ensure no other applications are polling the inverter
  4. Restart inverter if possible

Data Issues

Problem: "Sensors showing 'unavailable'"

Possible Causes:

  • Inverter is in night mode (expected behavior)
  • Temporary connection failure
  • Protocol communication error

Solutions:

  1. Check if it's nighttime (sensors automatically become unavailable)
  2. Review logs for connection errors
  3. Wait for sunrise if inverter is in night mode
  4. Restart integration if issue persists during day

Problem: "Incorrect sensor values"

Possible Causes:

  • Inverter reporting wrong data
  • Unit conversion issues
  • Protocol misinterpretation

Solutions:

  1. Compare values with inverter display/app
  2. Enable diagnostic sensors for detailed analysis
  3. Check inverter firmware version
  4. Report issue with diagnostic data

Configuration Issues

Problem: "Integration won't start"

Possible Causes:

  • Invalid configuration
  • Network not ready during startup
  • Dependency conflicts

Solutions:

  1. Check Home Assistant logs for specific errors
  2. Verify all configuration values are valid
  3. Restart Home Assistant completely
  4. Remove and re-add integration

Problem: "Reconfiguration fails"

Possible Causes:

  • New settings are invalid
  • Integration is busy updating
  • Connection test failed

Solutions:

  1. Verify new host/port settings are correct
  2. Wait for current update cycle to complete
  3. Test connection manually before applying changes

Getting Help

If you encounter issues not covered here:

  1. Enable Debug Logging: Add to configuration.yaml:

    logger:
      logs:
        custom_components.solarmax: debug
  2. Collect Diagnostic Data:

    • Go to Settings → Devices & Services
    • Find Solarmax Inverter integration
    • Click device name → Download Diagnostics
  3. Report Issues: Create a GitHub issue with:

    • Integration version
    • Home Assistant version
    • Inverter model
    • Error logs
    • Diagnostic data (remove sensitive information)

Translations

The integration is fully localized using Home Assistant's built-in translation system. All UI strings, entity names, sensor states, and error messages are translated.

Available Languages

Language Code Status
English en ✅ Complete
German de ✅ Complete
French fr ✅ Complete

What is Translated

  • Config & options flow — All setup and reconfiguration labels, descriptions, and error messages
  • Entity names — All sensor names displayed in the Home Assistant UI
  • Status codes (SYS) — Human-readable inverter operating states, e.g. "MPP operation", "Low irradiation"
  • Alarm codes (SAL) — Human-readable alarm descriptions, e.g. "Insulation fault DC side"
  • Error & repair messages — Connection errors, timeout messages, and repair issue descriptions

Status & Alarm Code Translations

The Status Code and Alarm Status sensors use Home Assistant's enum sensor translation, meaning their values are automatically displayed in the user's configured language.

Status code states (SYS register, ~110 codes mapped — only a subset shown; the full list is in const.py):

Code Key English
20000 no_communication No communication
20001 in_operation In operation
20002 low_irradiation Low irradiation
20003 starting_up Starting up
20004 mpp_operation MPP operation
20005 fan_running Fan running
20006 max_power_operation Maximum power operation
20007 temperature_limitation Temperature limitation
20008 grid_operation Grid operation
20009 dc_current_limited DC current limited
20010 ac_current_limited AC current limited
20011 test_mode Test mode
20012 remote_controlled Remote controlled
20013 start_delay Start delay
20014 external_limitation External limitation
20015 frequency_limitation Frequency limitation
20016 restart_limitation Restart limitation
20017 booting Booting
20018 insufficient_boot_power Insufficient boot power
20019 insufficient_power Insufficient power
20021 uninitialized Uninitialized
20022 disabled Disabled
20023 idle Idle
20024 powerunit_not_ready Power unit not ready
20050 program_firmware Programming firmware
20105 insulation_fault_dc Insulation fault DC
20109 vdc_too_high DC voltage too high
20114 leakage_current_high Leakage current too high
20115 no_grid No grid
20116 grid_frequency_high Grid frequency too high
20117 grid_frequency_low Grid frequency too low
20118 mains_error Mains error
20119 vac_10min_too_high AC voltage 10min too high
20122 grid_voltage_high Grid voltage too high
20123 grid_voltage_low Grid voltage too low
20124 temperature_too_high Temperature too high
20125 grid_current_asymmetric Grid current asymmetric
20126 external_input_error_1 External input error 1
20127 external_input_error_2 External input error 2
20129 incorrect_rotation Incorrect rotation direction
20130 wrong_device_type Wrong device type
20131 main_switch_off Main switch off
20132 diode_overtemperature Diode overtemperature
20134 fan_defective Fan defective
20145 dfdt_too_high df/dt too high
20150 ierr_step_too_high Ierr step too high
20154 shutdown_1 Shutdown 1
20155 shutdown_2 Shutdown 2
20157 insulation_fault_dc_3 Insulation fault DC (3)
20172 vac_too_high_2 AC voltage too high (2)
20173 vac_too_low_2 AC voltage too low (2)
20176 error_dc_polarity Error DC polarity
20180 vdc_too_low DC voltage too low
20181 blocked_external Blocked external
20189 l_n_interchanged L and N interchanged
20190 below_average_yield Below-average yield
20191 limitation_error Limitation error
20999 device_error_999 Device error 999
offline_night Offline (Night)
connection_failed Connection failed
unknown Unknown

Codes 20101–20199 not listed above are mapped as generic device_error_NNN states. All states are translated into English, German, and French.

Alarm code states (bitmask — multiple alarms are detected, and the individual active alarms are listed in the active_alarms attribute):

Key English German French
no_error No error Kein Fehler Aucune erreur
external_fault_1 External fault 1 Externer Fehler 1 Défaut externe 1
insulation_fault_dc Insulation fault DC side Isolationsfehler DC-Seite Défaut d'isolation côté DC
earth_fault_current Earth fault current too high Fehlerstrom Erde zu groß Courant de défaut à la terre trop élevé
fuse_break_center_earth Fuse break center earth Sicherungsbruch Mittelpunkterde Rupture de fusible terre centrale
external_alarm_2 External alarm 2 Externer Alarm 2 Alarme externe 2
long_term_temp_limit Long-term temperature limitation Langzeit-Temperaturbegrenzung Limitation de température à long terme
ac_feed_in_error AC feed-in error Fehler AC-Einspeisung Erreur d'injection AC
external_alarm_4 External alarm 4 Externer Alarm 4 Alarme externe 4
fan_defect Fan defect Ventilator defekt Ventilateur défectueux
fuse_break Fuse break Sicherungsbruch Rupture de fusible
temp_sensor_failure Temperature sensor failure Ausfall Temperatursensor Défaillance du capteur de température
multiple_alarms Multiple alarms Mehrere Alarme Alarmes multiples

Adding a New Language

To contribute a new language translation:

  1. Copy custom_components/solarmax/translations/en.json to a new file named with the BCP 47 language code (e.g. es.json for Spanish, nl.json for Dutch).
  2. Translate all string values — do not change any keys.
  3. Keep all placeholder variables intact (e.g. {host}, {port}, {failures}).
  4. Submit a pull request.

Example for a new file es.json:

{
  "config": {
    "step": {
      "user": {
        "title": "Inversor Solarmax",
        ...
      }
    }
  },
  "entity": {
    "sensor": {
      "sys": {
        "name": "Código de estado",
        "state": {
          "grid_operation": "Operación en red",
          ...
        }
      }
    }
  }
}

Contributing

Contributions are welcome! Please feel free to submit a Pull Request.

License

This project is licensed under the MIT License - see the LICENSE file for details.

About

Home Assistant integration for Solarmax inverters (mainly pre-2015 models with MaxComm tcp protocol)

Topics

Resources

Stars

2 stars

Watchers

2 watching

Forks

Releases

Used by

Contributors

Languages