98 changes: 98 additions & 0 deletions docs/developer-guide/andes-compatibility.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,98 @@
# ANDES compatibility roadmap

This document records the work required for GridDyn to load and solve ANDES
cases. It is intentionally a living checklist: a model is not complete until
its importer mapping and a numerical regression test are both present.

## Status terms

| Status | Meaning |
| ------------------ | -------------------------------------------------------------------------------------------- |
| Implemented | GridDyn model, ANDES importer mapping, and a numerical test exist. |
| Partial | A GridDyn analogue exists, but the mapping, controls, or numerical validation is incomplete. |
| Planned | No implementation work has started. |
| Untriaged | Included in the ANDES inventory, but its GridDyn-equivalence review has not started. |
| No direct analogue | Requires a new GridDyn model rather than reader-only work. |

## Power-flow model mapping

| ANDES model(s) | GridDyn mapping | Status | Notes |
| -------------------------------------------------- | -------------------------- | ------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| `Bus` | `AcBus` | Implemented | Base voltage, initial voltage, and angle are imported. |
| `PQ` | `ZipLoad` | Implemented | Constant-power portion is imported. |
| `PV`, `Slack` | `AcBus` plus `Generator` | Implemented | Active-power and voltage targets are imported. |
| `Line` | `AcLine` | Partial | `r`, `x`, `b`, tap, phase shift, and status are imported. ANDES line-rated-voltage (`Vn1`/`Vn2`) base conversion, including its implicit 110 kV default, still needs an equivalent mixed-base implementation. |
| `Area` | `GridArea` | Partial | A GridDyn analogue exists; ANDES `Area` is not yet imported. |
| `Shunt` | fixed-admittance `ZipLoad` | Partial | The equivalent exists but needs a direct mapping and test. |
| `ShuntSw` | `loads::Svd` | Partial | Both provide switched reactive support; block/control semantics need mapping and numerical tests. |
| `ShuntTD` | fixed shunt for power flow | Partial | Its steady-state behavior follows `Shunt`; its time-domain phase-voltage outputs are not represented. |
| `Jumper` | `links::ZBreaker` | Partial | Both merge buses through a zero-impedance connection; no importer mapping/test yet. |
| `Motor3`, `Motor5` | `MotorLoad3`, `MotorLoad5` | Partial | Candidate GridDyn models exist; parameter mapping and initialization comparisons remain. |
| `Fortescue` | none | No direct analogue | Requires a multi-terminal positive-/negative-/zero-sequence interface model. |
| `Node`, `Ground` | `DcBus` | Implemented | Ground is imported as a DC swing reference. |
| `R`, `L`, `C`, `RLs`, `RCp`, `RLCp`, `RCs`, `RLCs` | `links::DcLink` | Implemented | ANDES current-balance convention is retained. Dynamic-form validation remains open. |
| `VSCShunt` | `links::VSCShunt` | Implemented | Three-terminal algebraic converter; impedance-base conversion is applied during import. |

## Dynamic-model roadmap

The present numerical suite covers power flow. Dynamic compatibility requires
matching model states, initialization, events, limits, and trajectories; not
only the final power-flow point.

| Work item | Status | Completion evidence |
| ---------------------------------------------- | ------- | ------------------------------------------------------------------------------------------------------------- |
| DC `L`/`C`/combined branch dynamics | Planned | ANDES and GridDyn trajectories from the same initialized DC case. |
| `VSCShunt` controls, losses, limits, and droop | Partial | Core algebraic controls are present; loss coefficients and limit enforcement need model and trajectory tests. |
| Motors (`Motor3`/`Motor5`) | Planned | State-name/initialization mapping plus disturbance trajectory comparisons. |
| Switched shunts | Planned | Block selection and switching-event comparisons. |
| Fortescue interface | Planned | New GridDyn component and unbalanced/interface regression cases. |
| Remaining ANDES dynamic families | Planned | Maintain a model-by-model inventory before adding importer mappings. |

## Dynamic-model inventory

This inventory is based on the 100 registered models in the local ANDES
installation. Rows intentionally retain the ANDES class names so that a row
can be split and checked off as soon as models in the same family diverge. A
model is not compatible merely because a similarly named GridDyn model exists:
it also needs native-input mapping, initialization, and a trajectory test.

| ANDES model(s) | GridDyn mapping / next action | Status |
| ------------------------------------------------------------------------------------------------------------------------------------------------------ | ----------------------------------------------------------------------------------------------------------------- | --------- |
| `GENCLS` | `GenModelClassical`; parameter and trajectory comparison required. | Partial |
| `GENROU` | `GenModelGENROU`; PSS/e DYR reader has a mapping, but native ANDES mapping and numerical validation are absent. | Partial |
| `TGOV1` | GridDyn governor; PSS/e DYR reader has a mapping, but native ANDES mapping and numerical validation are absent. | Partial |
| `EXDC2` | GridDyn DC exciter; PSS/e DYR reader has a mapping, but native ANDES mapping and numerical validation are absent. | Partial |
| `ZIP`, `FLoad` | GridDyn static/dynamic load models; identify exact parameter and frequency-response equivalence. | Partial |
| `Motor3`, `Motor5` | `MotorLoad3`, `MotorLoad5`; parameter mapping and trajectory comparisons required. | Partial |
| `ACE`, `ACEc`, `COI` | Map area-control and center-of-inertia services. | Untriaged |
| `PLBVFU1`, `IEEEVC` | Map playback and voltage-compensation controls. | Untriaged |
| `TG2`, `TGOV1DB`, `TGOV1N`, `TGOV1NDB`, `IEEEG1`, `IEESGO`, `GAST`, `HYGOV`, `HYGOVDB`, `HYGOV4` | Governor-family inventory and model-by-model equivalence review. | Untriaged |
| `SHAFT5` | Multi-mass shaft model; map states and mechanical interfaces. | Untriaged |
| `IEEEX1`, `ESDC1A`, `ESDC2A`, `EXST1`, `ESST3A`, `SEXS`, `IEEET1`, `EXAC1`, `EXAC2`, `EXAC4`, `ESST4B`, `AC8B`, `IEEET3`, `ESAC1A`, `ESST1A`, `ESAC5A` | Exciter-family inventory; review the remaining classes individually. | Untriaged |
| `IEEEST`, `ST2CUT` | Power-system stabilizer models; identify GridDyn analogue or implement. | Untriaged |
| `BusFreq`, `BusROCOF`, `PMU`, `PLL1`, `PLL2`, `FreqDiv` | Measurement and frequency-estimation models. | Untriaged |
| `REGCA1`, `REGCP1`, `REECA1`, `REECA1E`, `REECA1G`, `REECB1`, `REPCA1`, `REGCV1`, `REGCV2`, `REGF1`, `REGF2`, `REGF3` | Renewable/inverter-controller family; map plant, electrical, and frequency-control blocks. | Untriaged |
| `WTDTA1`, `WTDS`, `WTARA1`, `WTPTA1`, `WTTQA1`, `WTARV1` | Wind-turbine drive-train and control models. | Untriaged |
| `PVD1`, `ESD1`, `EV1`, `EV2`, `DGPRCT1`, `DGPRCTExt` | Distributed energy-resource and protection models. | Untriaged |
| `Fault`, `Alter`, `TimeSeries`, `Toggle` | Event/action semantics and time-series input mapping. | Untriaged |
| `Summary`, `Output` | Reporting configuration; define output-channel mapping after model compatibility. | Untriaged |

## Numerical-regression policy

- Keep minimized ANDES-derived input cases and captured reference results in
`test/test_files/andes_tests/`.
- The regular C++ tests must not execute ANDES. Refresh a reference only by
running the documented ANDES case deliberately and reviewing the diff.
- Each reference file stores its tolerance. Start with `1e-6` p.u. for
well-conditioned power-flow comparisons; relax only with a documented
solver-conditioning reason.
- Compare selected voltages, angles, injections, and flows. A successful
solve by itself is not sufficient evidence of compatibility.

## Current reference cases

| Case | Coverage |
| -------------------------- | ----------------------------------------------------------------------- |
| `andes_kundur_vsc_pflow` | 10-bus AC network, DC resistor, PQ/VQ VSC controls, and AC/DC coupling. |
| `andes_two_bus_pflow` | Minimal AC Slack/PQ/Line power flow. |
| `andes_vsc_resistor_pflow` | Minimal AC/DC `VSCShunt` plus DC resistance power flow. |
1 change: 1 addition & 0 deletions src/fileInput/CMakeLists.txt
Original file line number Diff line number Diff line change
Expand Up @@ -42,6 +42,7 @@ set(formattedfileInput_sources
gridReadPSAT.cpp
readMatDyn.cpp
gridDynReadCSV.cpp
gridReadAndes.cpp
readMatlabData.cpp
loadGDZ.cpp
)
Expand Down
9 changes: 6 additions & 3 deletions src/fileInput/fileInput.cpp
Original file line number Diff line number Diff line change
Expand Up @@ -11,6 +11,7 @@
#include "formatInterpreters/jsonReaderElement.h"
#include "formatInterpreters/yamlReaderElement.h"
#include "gmlc/utilities/stringOps.h"
#include "gridReadAndes.h"
#include "griddyn/GridDynSimulation.h"
#include "readElement.h"
#include "readElementFile.h"
Expand Down Expand Up @@ -153,13 +154,13 @@ void loadFile(std::unique_ptr<GridDynSimulation>& gds,
}

std::unique_ptr<GridDynSimulation> readSimXMLFile(const std::string& fileName,
ReaderInfo* ReaderInfoPtr)
ReaderInfo* readerInfoPtr)
{
if (!std::filesystem::exists(fileName)) {
return nullptr;
}
return std::unique_ptr<GridDynSimulation>(static_cast<GridDynSimulation*>(
loadElementFile<XmlReaderElement>(nullptr, fileName, ReaderInfoPtr)));
loadElementFile<XmlReaderElement>(nullptr, fileName, readerInfoPtr)));
}

void loadFile(CoreObject* parentObject,
Expand Down Expand Up @@ -201,7 +202,9 @@ void loadFile(CoreObject* parentObject,
} else if (ext == "epc") {
loadEpc(parentObject, fileName, *readerInf);
} else if (ext == "json") {
loadElementFile<JsonReaderElement>(parentObject, fileName, readerInf);
if (!loadAndesJson(parentObject, fileName)) {
loadElementFile<JsonReaderElement>(parentObject, fileName, readerInf);
}
} else if ((ext == "yaml") || (ext == "yml")) {
loadElementFile<YamlReaderElement>(parentObject, fileName, readerInf);
} else if (ext == "gdz") { // gridDyn Zipped file
Expand Down
2 changes: 1 addition & 1 deletion src/fileInput/fileInput.h
Original file line number Diff line number Diff line change
Expand Up @@ -74,7 +74,7 @@ enum ReaderFlags {
};

std::unique_ptr<GridDynSimulation> readSimXMLFile(const std::string& fileName,
ReaderInfo* ReaderInfoPtr = nullptr);
ReaderInfo* readerInfoPtr = nullptr);

void addFlags(BasicReaderInfo& bri, const std::string& flags);

Expand Down