15 changes: 15 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
@@ -1,5 +1,20 @@
# CHANGELOG

## Version 2.3.1, 2026-07-20, `kezarjg`

- Fix: correct the inverted battery-power sign on smart 453/forfour (`SQ`) and smart
ED/fortwo (`SE`). Both OVMS smart modules report `v.b.power` with the wrong sign —
negative while driving (consuming), positive while charging — the opposite of the
OVMS core / Iternio convention. ABRP uses `power` for consumption calibration, so it
read consumption as regen and the calibrated reference consumption drifted toward zero
(issue #40). `overrideMetricMap` now corrects `power` for these vehicles by keeping the
module's power magnitude and taking its sign from `v.b.current`, which the same modules
report correctly. This is self-healing: `v.b.current` is correct in both the current
(buggy) and a future upstream-fixed firmware, so once the module's `v.b.power` sign is
fixed the correction becomes a no-op — no plugin change needed to retire it. Only
`power` is affected; `current`, `is_charging`, and `is_dcfc` are unchanged. Upstream
firmware bugs filed separately against `vehicle_smarteq` and `vehicle_smarted`.

## Version 2.3.0, 2026-06-25, `kezarjg`

- Switched telemetry to batched bulk uploads (`/1/tlm/bulk`) behind a queue, with
Expand Down
21 changes: 20 additions & 1 deletion lib/abrp.js
Original file line number Diff line number Diff line change
Expand Up @@ -5,7 +5,7 @@

// Module constants
const OVMS_API_KEY = '32b2162f-9599-4647-8139-66e9f9528370'
const VERSION = '2.3.0'
const VERSION = '2.3.1'
const Logger = logger()

// Configuration constants
Expand Down Expand Up @@ -311,6 +311,25 @@ function overrideMetricMap() {
};
}
break;
case 'SQ':
case 'SE':
// smart 453/forfour (SQ) and smart ED/fortwo (SE) report v.b.power with an
// inverted sign (negative while driving/consuming) until the upstream firmware
// fix lands (see iternio/ovms-link#40). v.b.current is correctly signed
// (discharge-positive) in BOTH the buggy and the fixed firmware, so keep power's
// magnitude and take its sign from current: corrects the bug now, and becomes a
// no-op once v.b.power's sign is fixed upstream (no plugin change needed).
if (entry.key === 'power') {
entry.requiredMetrics = ['v.b.power', 'v.b.current'];
entry.metric = function(metrics) {
var power = metrics['v.b.power'];
var current = metrics['v.b.current'];
if (current < 0) { return -Math.abs(power); }
if (current > 0) { return Math.abs(power); }
return power; // current == 0: power is ~0, sign irrelevant
};
}
break;
// Add cases for other vehicle types as needed
}
});
Expand Down
62 changes: 62 additions & 0 deletions lib/abrp.test.js
Original file line number Diff line number Diff line change
Expand Up @@ -816,3 +816,65 @@ describe('charge/drive overlap state machine', () => {
expect(count('ticker.1')).toBe(1) // sampler subscribed at startup
})
})

// smart 453/forfour (SQ) and smart ED/fortwo (SE) report v.b.power with an inverted
// sign (charge-positive) until the upstream firmware fix; v.b.current is correctly
// signed in both firmware states. overrideMetricMap corrects power by keeping its
// magnitude and taking its sign from current: fixes the bug now, no-op once fixed
// upstream. See iternio/ovms-link#40.
describe('overrideMetricMap: smart SQ/SE power sign correction', () => {
function withSmart(present, vtype) {
const abrp = loadAbrp({
OvmsMetrics: {
HasValue: (k) => Object.prototype.hasOwnProperty.call(present, k),
GetValues: (keys) => {
const o = {}
keys.forEach((k) => {
o[k] = present[k]
})
return o
},
Value: (k) => (k === 'v.type' ? vtype : present[k]),
},
})
abrp.__test.overrideMetricMap()
return abrp
}

test('SQ: inverted power while driving is corrected to discharge-positive', () => {
// driving: current +9A (correct, discharge), power reported -3.0kW (inverted)
const abrp = withSmart({ 'v.b.power': -3.0, 'v.b.current': 9 }, 'SQ')
expect(abrp.getOVMSMetric('power')).toEqual([true, 3.0])
})

test('SQ: inverted power while charging is corrected to charge-negative', () => {
// charging: current -20A (correct, charge), power reported +7.0kW (inverted)
const abrp = withSmart({ 'v.b.power': 7.0, 'v.b.current': -20 }, 'SQ')
expect(abrp.getOVMSMetric('power')).toEqual([true, -7.0])
})

test('SQ: already-correct power (post upstream fix) passes through unchanged', () => {
const abrp = withSmart({ 'v.b.power': 3.0, 'v.b.current': 9 }, 'SQ')
expect(abrp.getOVMSMetric('power')).toEqual([true, 3.0])
})

test('SQ: zero current leaves power as-is (magnitude ~0, sign irrelevant)', () => {
const abrp = withSmart({ 'v.b.power': -0.02, 'v.b.current': 0 }, 'SQ')
expect(abrp.getOVMSMetric('power')).toEqual([true, -0.02])
})

test('SE shares the smart override: inverted power corrected', () => {
const abrp = withSmart({ 'v.b.power': -3.0, 'v.b.current': 9 }, 'SE')
expect(abrp.getOVMSMetric('power')).toEqual([true, 3.0])
})

test('SQ: power is unsupported when v.b.current is absent', () => {
const abrp = withSmart({ 'v.b.power': -3.0 }, 'SQ')
expect(abrp.getOVMSMetric('power')).toEqual([false, null])
})

test('non-smart vehicle: power is a plain passthrough (no sign correction)', () => {
const abrp = withSmart({ 'v.b.power': -3.0, 'v.b.current': 9 }, 'UNKNOWN')
expect(abrp.getOVMSMetric('power')).toEqual([true, -3.0])
})
})