Phase 2 — calibration: card calibration, accuracy screen, accuracy tooling - #4
Conversation
…engine - CalibrationRepository (DataStore Preferences) stores the card calibration and a calibrationVersion that counts every user change; implausible or incomplete values read as no calibration (ADR-024). - PhysicalScaleProvider.resolve: the card over xdpi/ydpi, only on the phone and panel resolution it was made on; the scale carries the version. - The service loads the stored calibration before converting the first sample and follows changes live; every MeasurementResult carries its calibrationVersion (spec §65). - New screens Kalibrace displeje (vertical bar in raw px, slider + 1 px steps, ADR-023) and Přesnost měření (spec §33), reachable from home. - Debug test list: runs form a series with MAE / MAPE on screen; TESTLIST line and debug CSV header carry the calibration in force. - tools/accuracy.py: ground truth CSV vs measured CSV -> MAE, MAPE; device_accuracy.py --csv-out writes that pair. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
…en's limit Measured on the OnePlus CPH2399: the bar area allowed only 1219 px while the card needs ~1356 px. Title and instructions now sit beside the bar (the card covers them once placed) and the controls are compact — the area now allows ~1600 px. In landscape the bar could only reach ~400 px and a nonsense calibration (+222 %) could be saved. A bar pinned at the screen's limit cannot have matched a longer card: Save is disabled and the hint says to hold the phone upright. Debug logcat lines carry the calibration version (cv=) the distance used. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
- Back from Kalibrace displeje returns to where it was opened (home or Přesnost); only a save or "use the automatic estimate" lands on Přesnost. - Save / skip act once: a double tap bumped the calibration version twice (verified on the test phone: v2 -> v3 after a double tap). - The instruction text scrolls when the bar area is short (landscape). Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
There was a problem hiding this comment.
💡 Codex Review
Here are some automated review suggestions for this pull request.
Reviewed commit: 933d342a2c
ℹ️ About Codex in GitHub
Your team has set up Codex to review pull requests in this repo. Reviews are triggered when you
- Open a pull request for review
- Mark a draft as ready
- Comment "@codex review".
If Codex has suggestions, it will comment; otherwise it will react with 👍.
Codex can also answer questions or update the PR. Try commenting "@codex address that feedback".
| scope.launch { | ||
| change() | ||
| onSaved() |
There was a problem hiding this comment.
Recover from calibration write failures
If DataStore.edit fails—for example because storage is full or an I/O error occurs—change() throws from this launch, so onSaved() is never called and committing remains true; the uncaught coroutine exception may also terminate the app. This affects both saving a card and selecting the automatic estimate. Catch the failure, re-enable the controls, and report it so the user can retry.
Useful? React with 👍 / 👎.
…one, what remains The continue prompt now resumes an in-progress phase on its existing branch instead of starting a new one from main. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
…app" Honza (2026-09-24): keep developing, decide autonomously, finish the whole app. Manual on-phone checks move to "Dluh ověření" in handoff.md (V1 Instagram/TikTok, V2 card calibration, V3 MAPE with the card); the continue prompt merges each phase after its gates and uses an emulator instead of Honza's phone. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Phase 2 per
PLAN.md— the most accurate px → mm scale available, with its method and confidence stored.What is in it
CalibrationRepository(DataStore Preferences): card calibration +calibrationVersion(counts the user's changes). Implausible or incomplete values read as "no card" (ADR-024).PhysicalScaleProvider.resolve: card (HIGH) overxdpi/ydpi(MEDIUM) — the card only on the phone and panel resolution it was made on.MeasurementResultcarries its calibration version, nothing is recomputed (spec §65).TESTLISTline and debug CSV header carry the calibration in force.tools/accuracy.py(ground truth CSV vs measured CSV → MAE, MAPE);device_accuracy.py --csv-out.measurement-model.md,architecture.md,accuracy-testing.md, README updated.Definition of Done (PLAN Phase 2)
cv=1xdpi/ydpi; card from another resolution →xdpi/ydpi(unit test); "Přeskočit – použít automatický odhad" switched the running service live (cv=2, 25.4 / ydpi, no reconnect)Reviews
/topshit7/10 over the cumulative diff — 3 findings fixed and verified on the phoneTests
🤖 Generated with Claude Code