SLEMS is a Home Assistant integration that manages home batteries and controllable consumers. Its goal is to operate the batteries in a grid friendly way, e.g. by shifting the charging time so that the daily feed-in peak is absorbed, based on forecasts of consumption and PV production.
The name is a combination of Slug (a funny word for a very interesting animal) and EMS (energy management system).
Supported batteries: SLEMS currently controls the Marstek Venus E 3.0 (Modbus TCP) directly. Other batteries can be added through the entities of their Home Assistant integration, read-only or controlled (experimental). If you would like to use SLEMS with another battery, please open an issue with the model and how it is connected (Modbus, local API, Home Assistant integration), and whether you could test it.
- Why SLEMS?
- Features
- Installation
- Setup
- Without batteries
- Batteries
- Consumers
- Dashboard
- Operation and control
- Language
- Roadmap
- Development
- License
Most home battery controls react to the moment: they keep the grid power at zero and charge whenever there is surplus. The battery is then full by late morning, and the midday peak goes into the grid anyway. SLEMS plans ahead and controls precisely:
- Grid friendly instead of full by 10 o'clock. From the PV and consumption forecasts SLEMS calculates a feed-in limit and charges the batteries with the surplus above it, so they absorb the feed-in peak and are still full in the evening. The limit is recalculated continuously and drops by itself when the day turns out worse than forecast.
- Its own consumption forecast. Learned from the long-term statistics of your house, with the weather and a separate heat pump model; vacation mode, night discharge to a forecast based reserve and a projection of the state of charge for today and tomorrow.
- Batteries and consumers in one plan. The surplus is distributed between batteries and controllable consumers (heating rod, heat pump, …) with priorities, battery priority until the charge is secured, minimum runtimes, external blocking and thermostat pauses. Daily targets (runtime, energy or temperature by a time of day) are met from the surplus first and only if needed from the batteries or the grid; per consumer you decide whether the batteries may supply it.
- Several batteries at their efficient point. SLEMS learns the conversion losses of every battery, runs as few batteries as useful and switches between them with a smooth transition.
- Feed-in cap. If you may feed in only part of the PV power (e.g. 60 % or nothing at all), SLEMS stores the energy above the limit and makes room in the batteries in time instead of curtailing PV.
- Prices in view. Tariffs as on the bill, with templates for Austria, Germany and Switzerland; day-ahead prices per quarter hour only with your consent, estimated until the next day's prices are published. The price aware control keeps the stored energy for expensive hours and can optionally charge cheaply from the grid or feed in when it pays; a monthly tariff comparison shows what another tariff would have cost.
- Precise control without oscillation. Event driven on every report of the smart meter; the learned response time of the batteries is compensated and the control gain adapts itself.
- Battery care and safety. State of charge window, power limits (e.g. 800 W), temperature charge limit, cell delta monitoring with active cell balancing, detection of batteries that do not respond, repair issues and notifications.
- Regular full charge without losing surplus. LFP batteries recalibrate their state of charge only when full. SLEMS charges the battery whose last full charge is the oldest first, one at a time and only with the surplus it would store anyway, and spares it when discharging so it starts the next day higher. It also recognises a full charge the BMS ends slightly below 100 %, and it measures the cell delta at the top.
- Learns instead of asking. Besides the consumption forecast, SLEMS learns the conversion losses and the response time of the batteries, the smart meter interval, the control gain and the consumption peaks; on request also the forecast buffers, the grid surplus targets, the control timing, the usable capacity of every battery and the power and thermostat behaviour of consumers (see Learned values). Every learned value can be switched back to a fixed one.
- Transparent and local. A dashboard with energy flow, forecast chart and all settings; everything runs locally in Home Assistant without a cloud. The simulation mode shows what SLEMS would do before it controls anything, also next to an existing battery integration.
- Try before you change. The simulation in the dashboard calculates the day plan with other settings (grid friendly charging, night discharge, feed-in cap, battery limits, forecasts ±%) and compares feed-in, grid import and state of charge with the current plan, without changing anything.
- Also without batteries. SLEMS can direct the PV surplus into consumers alone (heating rod, wallbox, dehumidifier, …), with daily targets, tariffs and forecasts (see without batteries).
When another solution fits better (today): many different battery brands (SLEMS talks directly only to the Marstek Venus E 3.0; other batteries are controlled through the entities of their integration, which is coarser) or electric vehicle charging. Omnibattery covers many battery models, evcc specialises in EV charging; evcc complements SLEMS well (see the evcc guide).
| Setup | Status |
|---|---|
| Any number of batteries, added/edited/removed at any time | ✅ |
| Smart meter, PV power and weather entity freely selectable | ✅ |
| Smart meter read directly over Modbus as well (SunSpec, e.g. SolarEdge), with the sensor as fallback | ✅ |
| Operating mode Off / Simulation (read-only) / Active | ✅ |
| Vacation switch and bad weather mode | ✅ |
| Repair issues, notifications and diagnostics | ✅ |
| Forecasts | Status |
|---|---|
| PV forecast from any solar forecast integration (Forecast.Solar, Solcast, …) | ✅ |
| Consumption forecast today/tomorrow (history + weather, heat pump temperature dependent), raised at once after a sudden rise | ✅ |
| Correction of the PV forecast during the day and forecast accuracy of PV and consumption | ✅ |
| Batteries | Status |
|---|---|
| Marstek Venus E 3.0 via Modbus TCP | ✅ |
| Battery from existing entities: read-only (e.g. while Omnibattery is in control) or controlled by set point, charge/discharge power or script, entities suggested from the device | ✅ (control experimental) |
| Battery efficiency (battery counters, learned or manual), learned usable capacity | ✅ |
| Wear costs per battery (from purchase price and cycles) in the planning | ✅ |
| Battery menu: pause the communication for firmware updates, disable a battery, open its device | ✅ |
| Distribution between batteries by efficiency, rotation with smooth transition | ✅ |
| Battery limits: minimum/maximum SoC, charge/discharge power limit (e.g. 800 W), temperature charge limit | ✅ |
| Detection of batteries that do not deliver the commanded power, confirmation of set points | ✅ |
| Cell delta and active cell balancing (Marstek Venus E 3.0) | ✅ |
| Self-test of a battery: effect at the smart meter, sign and unit of the power, energy counters, state of charge, response time | ✅ |
| Regular full charge for the SoC calibration of LFP cells (one battery at a time, from the surplus, spared when discharging) | ✅ |
| Consumers | Status |
|---|---|
| Consumers with own power/energy sensors, inside or outside the smart meter | ✅ |
| Heat pump as consumer type (weather dependent forecast) | ✅ |
| Control of consumers: on/off or power set point, priority, minimum runtime/pause, avoid short runs, external blocking, control switchable per consumer | ✅ |
| Consumers with their own thermostat: pauses recognised, their power goes to the batteries meanwhile | ✅ |
| Temperature sensors of a storage: learned energy per degree, remaining capacity | ✅ |
| Role of a consumer in the feed-in cap (supporting, normal, never) | ✅ |
| Daily targets: runtime, enabled time, energy or temperature, with deadline and source (surplus, batteries, grid) | ✅ |
| Battery support per consumer (always, automatic with the energy the batteries can spare, never) | ✅ |
| Wallbox / evcc loadpoint: current set point in A with phases, start/stop (guide) | ✅ (not yet tested with a real wallbox) |
| Planning and control | Status |
|---|---|
| Distribution of surplus between batteries and consumers (priorities, split, minimum runtime/pause) | ✅ |
| Real-time control of batteries and consumers (operating mode active) | ✅ |
| Averaged grid surplus (0–300 s) | ✅ |
| Grid surplus targets for charging/discharging, maximum export while discharging | ✅ |
| Grid friendly charging: absorb PV feed-in peaks | ✅ |
| Feed-in cap: store the PV energy above a feed-in limit, make room in time | ✅ |
| Night discharge to a forecast based reserve | ✅ |
| Import peak shaving at low state of charge (manually enabled) | ✅ |
| Dashboard | Status |
|---|---|
| Dashboard (sidebar panel): energy flow, key figures, daily forecast and plan chart, batteries, consumers, settings | ✅ |
| Simulation in the dashboard: day plan with other settings compared with the current one (today or tomorrow), with the price chart | ✅ |
| Tariffs and prices | Status |
|---|---|
| Tariffs as on the bill (time windows, VAT per group, percent levies) with a check against a bill | ✅ |
| Tariff templates: Austria (grid fees of all grid areas, levies, suppliers incl. options such as a green upgrade), Germany (levies, EEG feed-in credit, grid fees of 19 grid operators incl. § 14a modules and metering), Switzerland (query of the ElCom open data); a general template for dynamic tariffs (market price plus the markup of the contract) | ✅ |
| Template updates: new prices, successor tariffs and corrections as a repair issue, reset to the template values | ✅ |
| Tariffs as YAML (import, export, own templates) with a prompt to create one from a bill with an AI | ✅ |
| Day-ahead prices per quarter hour (APG, SMARD, Energy-Charts) and official monthly market values (E-Control) only with consent; no feed-in credit at negative prices where the tariff says so (EEG) | ✅ |
| Monthly tariff comparison: import costs and feed-in credit per tariff, tariffs shown or hidden, estimated saving of the price aware control | ✅ |
| Price aware control: stored energy kept for the expensive hours, grid part of daily targets in the cheapest window, optional charging from the grid and feeding in from the batteries | ✅ |
| Estimated day-ahead prices until the next day's prices are published (profile of the last days, weekends and public holidays) | ✅ |
The button opens SLEMS in HACS of your Home Assistant instance and adds the custom repository; then continue with step 2. Or by hand:
- HACS → ⋮ → Custom repositories → add
https://github.com/gojux/SLEMS, type Integration. - Install SLEMS and restart Home Assistant.
Copy custom_components/slems into the custom_components folder of your
Home Assistant configuration and restart Home Assistant.
Requires Home Assistant 2026.9 or newer.
- Settings → Devices & services → Add integration → SLEMS.
- Select the grid power entity of your smart meter (positive = import, negative = export; enable invert if your meter uses the opposite sign), optionally PV power, PV forecast and weather.
- On the SLEMS integration page choose Add battery for every battery and Add consumer for every consumer you want to measure or control.
The entity of the smart meter is updated once per polling cycle of its integration, often only about once per second, and then shows only a part of the meter's values. With Also read the smart meter over Modbus SLEMS reads the grid power directly from a SunSpec meter, e.g. the meter at a SolarEdge inverter, every 0.5 seconds (0.2 to 5 s). The control sees every value sooner; the gain is largest with fast batteries.
- SLEMS uses the shared Modbus connection of Home Assistant. As long as the inverter integration keeps the inverter's only Modbus TCP connection to itself (e.g. SolarEdge Modbus Multi), enter a Modbus proxy in front of the inverter as host. If the inverter integration shares its connection one day, the inverter itself can be entered and the proxy is no longer needed.
- SLEMS finds the meters in the SunSpec model chain; with several meters (e.g. export+import and consumption) you choose the one at the grid connection point, the current power of each helps to recognise it.
- The sign is found automatically by comparing a few values with the grid power entity; this needs some import or export (at least 100 W). Otherwise choose it by hand.
- The entity stays required: it is the history, the basis of the forecasts
and the fallback. While no Modbus value is newer than 3 intervals (at least
5 seconds), SLEMS uses the entity; after 5 minutes without Modbus a repair
issue appears. The sensor Smart meter update interval shows the source as
attribute
source. - When the source is switched, the learned battery response times start again, since they contain the delay of the old source.
With Add tariff on the SLEMS integration page you enter your electricity tariff the way your bill shows it; the values stay in your Home Assistant. Prices are in the currency set in Home Assistant under Settings → System → General (hundredths per kWh, e.g. ct or Rp., and whole amounts per year); market prices come in euro.
- Name, role (current tariff or comparison tariff) and VAT: for the consumption bill, for the feed-in energy (often 0 % for private PV) and for the other feed-in items. Separate contracts for import and feed-in: add both as current tariff, they count together as one. A comparison tariff with items for only one side (e.g. a dynamic supply tariff) takes the other side from the current tariffs, so the comparison always shows total costs.
- The lines of the bill one by one: name, side (consumption or feed-in), group (energy, grid, levies) and the net price (without VAT; SLEMS adds the VAT of step 1) in ct/kWh or €/year (charged per day; a discount is negative). If the bill only shows gross prices, enter those and set the VAT to 0 %. Optionally only in some months, on some weekdays or in a time window of the day, e.g. a cheaper grid price at noon in summer: a line with a window replaces the line of the same name in its window. A price change is the same line again with valid from. On the feed-in side the energy price is your credit.
- Check against a bill: enter its period and amounts; SLEMS computes the period with the tariff and your recorded grid import and export and shows both amounts and the deviation, per side and group.
Import and export as YAML. Instead of entering the lines, Add tariff →
Paste YAML takes a tariff file (format slems-tariff with a version
number; prices net, plus optional supplier, validity from/to and source).
Export as YAML in the menu of the lines shows a tariff as such a file, e.g.
to save it or to use it in another SLEMS. An AI can turn a bill into such a
file: prompt and instructions. A file of a newer
format version is refused with a hint to update SLEMS; older versions are
converted.
Templates. Add tariff → From templates offers tariffs with public list
prices, per country and part of the bill: the energy of a supplier, the grid
fees of a grid area, the levies. First choose the energy tariff; the grid
tariff usually combined with it (households) and the levies of the country
are then preselected, each with the prices in effect today, and SLEMS
combines them into one tariff (then compare it with a bill). The result is
an ordinary tariff you can edit; later changes of a template do not touch
it. Options of a price sheet (e.g. an upgrade to certified green electricity,
a bonus for an online bill, the metering of the feed-in direction) are chosen
in an extra step. A feed-in tariff of its own is a template of its own, added
as a separate current tariff (SLEMS counts all current tariffs as one
contract). It remembers its templates, though: when an update of SLEMS (or an own
template) brings newer prices or a successor tariff, a repair issue tells
you, as it does when a current tariff is past its end. Update to the new
prices in the menu of the lines takes them over (with several successors you
choose one, or none): the current lines end the day before, the new ones
apply from then on, the old prices stay for the past and own lines stay as
they are. A corrected template (e.g. a misplaced decimal point, same dates)
is offered the same way: the values are corrected in place, also for the
past, lines you changed yourself stay. Reset to the template values undoes
your own changes of the template lines. Own templates: YAML files in
the folder slems_tariff_templates of your Home Assistant configuration.
Suggest a template for everyone as an
issue with the source of the
prices. Switzerland: Add tariff → From ElCom queries the open data of
ElCom (ld.admin.ch) for the tariff of your municipality and consumption
category (energy, grid and levies, excluding VAT, as the mean of the
category; high and low tariff times are averaged); the next year, published
in September, is offered as new prices, in the background only with
Fetch market prices switched on. Austria: the grid fees of every grid area (network level 7, from the
grid fee ordinance, with the reduced price from April to September 10–16 h)
and the federal levies; the metering fee is entered at its legal maximum
(your grid operator may charge less) and municipal levies (e.g. the
Gebrauchsabgabe in Vienna) are not included. Austria and Germany: a general
template Dynamic tariff (energy at the day-ahead price per quarter hour);
enter the markup and the monthly fee of your contract afterwards in its
lines, as suppliers of dynamic tariffs mostly publish them only per postcode.
Germany: the federal levies
(electricity tax, surcharges and the concession levy by the size of the
municipality, at its legal maximum), the grid fees of the largest grid
operators (Westnetz, Bayernwerk, E.DIS, Avacon, Netze BW, Schleswig-Holstein
Netz, Stromnetz Berlin, Hamburger Energienetze, EWE NETZ, N-ERGIE Netz, SWM
Infrastruktur, RheinNetz, enercity Netz, Thüringer Energienetze, Netze ODR,
LEW Verteilnetz, Westfalen Weser Netz, Syna, Mainnetz; also with § 14a module 1 and
module 1 + 3 with time variable prices for controllable devices; metering as
an option at its legal maximum by meter type and consumption) and
the EEG feed-in credit of PV plants up
to 10 kWp per commissioning period; for plants commissioned since 25 February
2025 the credit is 0 while the day-ahead price is negative (Fetch market
prices needed). A line can have Zero at negative market prices for this. A line may also be a percent of the group (e.g. a municipal levy of
7 % on the energy).
Where the energy comes from: SLEMS records grid import and feed-in per quarter hour itself from every grid value (kept for 400 days), so import and feed-in within an hour do not cancel out and dynamic prices apply per quarter hour. For exact totals choose the energy counters of your smart meter (Grid import energy (counter) / Grid export energy (counter)) in the SLEMS options: the recorded quarter hours are then scaled to the counter of each hour. Hours before the recording use the counters, without counters the hourly mean of the grid power (less exact).
Dynamic tariffs and market prices. A line can also follow the day-ahead market: spot price (hourly) or monthly market price, each as market price × (1 + share in %) + price in ct/kWh, e.g. "spot × 1.05 + 1.2 ct" or "monthly market price − 0.5 ct" for the feed-in. Published monthly market prices can be entered per month (e.g. "2026-08: 7.1"); months without a value use the mean of the spot prices weighted by your feed-in. If the price follows an official monthly value, choose it as the line's Monthly value (Austria: the reference market value for PV, wind or hydro published by E-Control according to § 13 EAG); SLEMS then fetches it with the market prices, the weighted mean stands in until it is published.
SLEMS only fetches market prices from the internet once you switch on Fetch market prices (off by default). Price source selects where from: APG (Austria), SMARD of the Bundesnetzagentur (Germany/Luxembourg) or Energy-Charts of Fraunhofer ISE (Austria, Germany/Luxembourg and Switzerland); the default follows the country set in Home Assistant. Swiss prices are in euro like all exchange prices. At the moment SLEMS only supports market prices in euro: with another currency set in Home Assistant, the tariff comparison and Check against a bill leave out tariffs that follow the market price, and a repair notice says so if the current tariff is one of them. SLEMS then loads the last 12 months once, stores them locally and fetches the next day after the day-ahead auction (from 13:00). The sensor Market price shows the price of the current quarter hour in ct/kWh without fees and VAT, with the source as attribution.
Price aware control (switch, off by default; needs a tariff): if the stored energy does not last for every hour until PV refills the batteries, they cover the hours with the highest import price of the current tariff and keep their energy in hours that are cheaper by at least the minimum gain (default 2 ct/kWh); there the house draws from the grid. The grid import stays the same, it only moves to cheaper hours – no charging from the grid and no feed-in from the batteries. Any time dependent price counts: market prices or time windows of a fixed tariff. Import peak shaving still applies. The strategy shows Price hold with the hours concerned, the day chart and the simulation include it. The price plans work in quarter hours (market prices change every quarter hour): the hourly consumption forecast is spread evenly over its quarters, PV comes from the forecast; the day chart shows their hourly means. Daily targets with the source + grid: if the forecast surplus is short for them anyway, the forced run starts in the window with the lowest mean import price before the deadline (cheaper by at least the minimum gain than at the latest start); the consumer card shows from … in the cheapest window.
Estimated prices: the day-ahead prices of the next day are published around 13:00. For the quarter hours after the last known price the price aware control plans with estimates: per time of day the median of the last 14 days of the same kind (working day, or weekend and public holiday of the bidding zone; in Switzerland the days off in at least half of the cantons), its swing around the mean of the day halved as a safety margin. So the night and a cloudy next day are planned before the real prices are known; a new plan follows as soon as they are. Only known negative prices start the plan for negative prices. The price chart shows the estimates faint.
Charge batteries from the grid (switch, off by default; only with price aware control): in a deficit SLEMS plans until PV refills the batteries (after the last known price with the estimated ones) which hours the batteries cover, which they hold and in which they charge from the grid. A charge must pay after the charge and discharge losses, the wear costs and the minimum gain; of equal plans the later charge wins, as home storage ages mostly with time at a high state of charge. Limits: Highest state of charge from the grid (default 90 %), Highest grid charge power (0 = the charge power of the batteries), the import limit of peak shaving and the space the feed-in cap needs when PV takes over. With a surplus nothing is charged from the grid. The plan includes the price hold; the strategy shows Grid charging with the energy, the start and the expected saving, the day chart the planned charging.
Negative prices: with price aware control and a negative import price or feed-in credit within the known prices, the plan also covers the surplus hours: the batteries keep room for the PV surplus of the negative hours (they take only part of the surplus before and feed in the rest at a positive price; strategy Room for cheaper hours) and, with Charge batteries from the grid, also charge from the grid when the import price including all fees is negative. Your own PV surplus is taken first. Highest grid import while charging from the grid (0 = no limit, e.g. for the main fuse) and the import limit of peak shaving cap the import. This only matters with a credit or an import price that follows the market price per hour.
Feed in from the batteries (switch, off by default; only with price aware control): the same plan may feed in from the batteries beyond the house's need when the credit of the hour is higher than what the energy is worth later plus the minimum gain – accepting grid import later. Not below the morning reserve, at most the maximum grid export while discharging and the feed-in cap. This only pays with a feed-in credit that follows the market price per hour; with a fixed or monthly credit the strategy says the option has no effect. Check your contract and any subsidy first: some do not allow feeding in energy that was charged from the grid.
Measured saving: the sensor Saving price control adds up per month what the price aware control saved: after every night (or other run until PV takes over) in which it held, charged or fed in, SLEMS compares the recorded costs with the same hours played as usual through the battery model, starting from the measured state of charge. Nights without such an action count nothing. The tariff comparison shows the value next to the estimate.
Every integration that provides a solar forecast for the Home Assistant energy dashboard can be selected, e.g. Forecast.Solar or Solcast. Several entries (e.g. one Forecast.Solar entry per roof plane) are summed up. SLEMS uses the finest resolution the provider delivers (e.g. 15 or 30 minutes). Forecast.Solar marks each period by its end; SLEMS takes this into account.
Recommendation: Helios Forecast (open source, no account or API key, computed locally with weather data from Open-Meteo). It learns from the production of your own PV system, including shading by trees or mountains, soiling and an orientation that is a few degrees off, and uses the existing long-term statistics of your energy sensor right away. It provides a forecast for the energy dashboard in 15 minute steps, so it can be selected in SLEMS directly.
The weather entity improves the consumption forecast, especially for a heat pump. Recommendations for Vorarlberg / the Alpine region:
- GeoSphere Austria AROME: high resolution model of the Austrian weather service, well suited for alpine valleys. Available in Home Assistant through custom integrations such as GeoSphere Austria Plus or GeoSphere Austria Next (HACS). The built-in GeoSphere Austria integration only provides station measurements, no forecast.
- Open-Meteo (built-in integration): no account needed, combines several weather models.
- Met.no (Home Assistant default): works everywhere, less detailed in alpine terrain.
SLEMS learns the consumption from the long-term statistics of Home Assistant and forecasts today and tomorrow hourly. Recent days count more than older ones, so changes are followed within days. Heat pumps are forecast from the outdoor temperature of the day, so a warm day in the heating season immediately predicts less heating energy. After a sudden rise (e.g. the heat pump starting the heating season) the forecast is raised at once: if the last three hours took on average at least 200 W and 30 % more than forecast, that excess is added to the next 24 hours, so the night discharge and the grid friendly charging plan with it until the learned forecast has caught up (card Forecast accuracy: Raised). It is never lowered this way. Two optional settings help at the start:
- Outdoor temperature: a temperature sensor with history. Without it, SLEMS records the temperature of the weather entity itself; the heat pump model then needs about a week before it uses the temperature.
- House consumption history: a power sensor of the house consumption with existing history (e.g. from another battery integration), used for the time before SLEMS recorded its own values.
Recommended setup when switching from another battery integration:
- Select that integration's house consumption sensor as House consumption history. SLEMS then learns from the full history right away. Without it, SLEMS derives the history from grid and PV only; the battery power before SLEMS is unknown, so charging and discharging would distort the learned consumption.
- Select an outdoor temperature sensor with history if one exists. Otherwise the heat pump forecast uses the mean of the last days until SLEMS has recorded about a week of temperatures.
- Holidays are currently treated like workdays.
Forecast accuracy (card in the overview, sensors Consumption forecast accuracy and PV forecast accuracy):
- Consumption: SLEMS recalculates the forecast of each of the last 14 days as it would have been made at midnight, with the history up to then, and compares it with the measured consumption. Shown are the accuracy of the daily energy (100 % minus the mean deviation), the tendency (too high or too low), the deviation per hour (how well the course of the day is hit), the data basis (days of consumption, days of heat pump data with temperature) and tomorrow's forecast with its expected deviation. The heat pump is recalculated with the measured temperature of the day, so its share looks somewhat better than it was.
- PV: past forecasts are not available from the solar forecast integration, so SLEMS records the forecast of each day at its start and compares it with the production in the evening. The card shows accuracy and expected deviation from 7 compared days on (before: collecting data), because a few days say little.
The sensor House consumption (used for the forecast and shown in the energy flow) is calculated as grid + PV − batteries. The smart meter often reports a change later than PV and batteries; a momentarily negative result is therefore replaced by the last valid value (for at most 30 seconds, then unknown).
SLEMS also works without any battery: add the consumers only.
- Works: directing the PV surplus into controlled consumers (heating rod, wallbox also with evcc, dehumidifier, heat pump through a switch input) with priorities, minimum runtime and pause, Avoid short runs and external blocking; daily targets with the sources surplus only and + grid (also in the cheapest window with price aware control); tariffs, bill check, market prices, tariff comparison and price chart; energy flow, consumption and PV forecast with their accuracy.
- Not without batteries: everything that charges, discharges or plans a battery – grid friendly charging, night discharge, import peak shaving, price hold, charging from the grid, feeding in from the batteries – and currently the feed-in cap (it needs a battery even with supporting consumers).
-
Marstek Venus E 3.0: host/IP, port (502) and Modbus unit ID. The battery accepts only one Modbus TCP connection. Never let two integrations (e.g. SLEMS and Omnibattery) talk to the same battery at the same time. Its sensor AC power is positive when discharging and negative when charging, as the Home Assistant energy dashboard expects for battery power.
Remote control: the Venus only follows set points while its remote control is on; Marstek's register list calls it RS485 control mode. Despite the name it does not need an RS485 cable: SLEMS controls the Venus over the LAN (Modbus TCP) and switches the remote control on and off itself; there is nothing to set up.
Search: when adding a Venus, SLEMS first searches the network of Home Assistant for batteries (TCP port 502, then a test read of the state of charge; a few seconds) and offers the ones found; batteries already added are left out. A battery whose single Modbus connection is held by another integration cannot be found.
Finding the IP address: Modbus TCP is only available on the LAN port of the battery (connect it with a network cable), not over Wi‑Fi. The Marstek app does not show the LAN IP address; look it up in your router / internet gateway / DHCP server (list of connected devices). Give the battery a fixed address there (DHCP reservation), so it does not change later. Alternatively scan your network for devices with the Modbus port open, e.g. with nmap (adjust the network to yours):
nmap -p 502 --open 192.168.0.0/24
Every address listed with
502/tcp openis a Modbus TCP device (nmap shows the MAC address when run withsudoin the same network, which helps to tell several batteries apart). When adding the battery, SLEMS checks the connection by reading its state of charge; stop other integrations using the battery first. -
Existing Home Assistant entities (control: experimental): any battery that another integration brings into Home Assistant. First choose the battery's device: SLEMS suggests its entities (state of charge, power, set points, mode, optional temperature, cell voltages and energy counters); check and correct them. Leave the device empty to choose everything by hand.
- Read only: SLEMS never sends commands, e.g. to run SLEMS in simulation mode side by side with an existing battery integration.
- Set point: one number entity with the signed power (+charge / −discharge, sign can be inverted).
- Separate charge and discharge power: one number each, optionally a mode select (charge / discharge / standby / automatic, the options are assigned in the next step).
- Script: a script of yours receives the power as variable
power_w(W, +charge / −discharge, 0 = standby); optionally a release script. This covers batteries controlled through actions (services). SLEMS waits until the script is done (at most 10 seconds) so its errors are noticed; keep it short (no waits).
Optionally a remote control switch or select (e.g. Manual battery control of Omnibattery) is switched on before the first set point and off when SLEMS releases the battery to Automatic, so it controls itself again; leave it empty if you switch it yourself. For controlling, the battery power sensor is required. Minimum time between commands suits integrations with a rate limit (often cloud based), Repeat set point every batteries that fall back to their own logic without new commands. Switch off the battery's own control (e.g. its zero export) in its integration, otherwise both control at the same time.
Response time: from a set point until the smart meter shows it, the path adds up: the integration writing the command (often in its own polling cycle, behind a cloud also with a rate limit), the battery itself and the smart meter's update interval. SLEMS learns the response time per battery (Details of the battery). Measured on one installation with the same Marstek Venus E 3.0 and the smart meter read over Modbus every 0.5 s: about 0.7–1.3 s directly over Modbus, about 4 s through Omnibattery (entities); batteries behind a cloud are usually slower still. A slower battery means more grid exchange after load changes and a coarser control; together with faster batteries, those take the changes first (see distribution between batteries). With cell voltages SLEMS uses gentle charging near the top, the cell delta and cell balancing as for a Venus (LFP cells). This control has been tested with simulated entities and with a Marstek Venus E 3.0 through Omnibattery; please report your experience with other devices in an issue.
Directly or through another integration? Where SLEMS supports a battery directly (Marstek Venus E 3.0 over Modbus), that is the better choice: it reacts faster, has fewer parts in between and gives SLEMS more data (cell voltages, counters, firmware, OTA state). Through another integration makes sense if the battery is not supported directly, if that integration must keep the battery's only Modbus connection, or if no network cable reaches it. The difference matters most with fast load changes (cooking, kettle).
Another battery model? If you would like SLEMS to support a model directly, please open an issue with manufacturer and model, interface (Modbus TCP/RTU, local API, cloud only), a register list or API documentation if available, and the Home Assistant integration that exists for it.
Example: a battery through Omnibattery. For a battery model SLEMS does not support directly, Omnibattery can do the communication and SLEMS the control:
- In Omnibattery switch on Manual battery control for the battery, so its own control stops.
- In SLEMS add the battery as Existing Home Assistant entities and choose the Omnibattery device. SLEMS suggests the entities (state of charge, power, charge and discharge power, operating mode, cell voltages, counters); check them.
- Switch off automations that control the battery, so only SLEMS sends set points.
State when released: what SLEMS leaves the battery in when it stops controlling it, e.g. in operating mode Off, without smart meter values or when the battery is removed from SLEMS. Automatic (default): the battery's own logic takes over again (e.g. its zero export); for a battery from entities this needs a remote control entity, a mode option for automatic or a release script. Standby: the battery stays idle at 0 W until something else takes it over; a Venus keeps its remote control on for this.
With several batteries SLEMS decides how many run and which: at low power a single battery is usually more efficient, at high power sharing is. When discharging the battery with the highest state of charge runs, when charging the one with the lowest. If the running battery drifts more than Battery rotation threshold (default 5 %) away from the best inactive one, SLEMS switches, at most once per Battery rotation minimum interval (default 15 min) and with a smooth transition: the power moves with Battery rotation ramp rate (default 100 W/s), but never takes longer than Battery rotation maximum ramp time (default 30 s). The conversion losses per power level are learned from the battery's AC and DC power.
Batteries that react at clearly different speeds (learned response times, the slowest at least twice and 3 s slower than the fastest, e.g. a Venus over Modbus next to a battery over a cloud integration): changes of the total power go to the fastest battery first and then move over to the efficient split with the response time of the slower ones. No battery works against the direction of the total.
Every battery has an Enabled switch. A disabled battery is still measured (its power is part of the energy balance), but it is neither planned with nor controlled, and it does not count towards the total state of charge. If it is discharging in active mode, the other batteries take over within 5 seconds before it is handed back to its own logic.
Optional in the battery configuration: purchase price and rated cycles (manufacturer). From them SLEMS computes the wear costs per kWh stored and delivered again: price ÷ (cycles × usable capacity), e.g. 1200 € ÷ (6000 × 5 kWh) = 4 ct/kWh. Price aware actions that cost an extra cycle (charging from the grid) only happen if they earn more than that. A price of 0 means no wear costs: field measurements of home storage systems show that they age mostly with time, temperature and state of charge and often reach their end of life before their rated cycles. Without the values SLEMS assumes a low estimate of 1 ct/kWh; Details of the battery then say so. The sensor Wear costs shows the value.
Round trip efficiency (AC to AC), one of three sources per battery:
- Battery counters (recommended for the Marstek Venus E 3.0 and for batteries from entities with energy counters): from the lifetime charge and discharge counters of the battery and its state of charge: (discharged + stored) / charged. The battery counts itself, fast and over its whole operating time, so the value is accurate at once and stable. The only assumption is an empty battery at the start of the counters; its influence disappears after a few cycles.
- Learned: SLEMS adds up the measured battery power itself (every 5 seconds) from the start of SLEMS. It only counts after about three full charge cycles (until then the start value applies), and short power peaks between two polls are missed. Recommended for batteries without their own counters.
- Manual: a fixed value, e.g. from the data sheet.
The efficiency is used where energy is converted: whether the PV surplus will fill the batteries (charge secured), grid friendly charging, the night discharge and the state of charge projection. It is not used to decide how many batteries run: for that SLEMS learns a separate loss curve per battery from the difference of AC and DC power at every power level (fixed loss of a running inverter plus losses rising with the power). From it the distribution calculates the number of batteries with the lowest total loss: at low power one battery, above the break-even point several (see Distribution between batteries). This works with every efficiency source, but only for batteries that report AC and DC power (Marstek Venus E 3.0).
When SLEMS takes over a battery from another integration (e.g. Omnibattery), the history of the old sensors (e.g. the charged and discharged energy used in the energy dashboard) can be carried over to the SLEMS sensors with HA Merge Sensor History. It copies states and long-term statistics, so the running totals of the energy dashboard continue.
- Make a full backup of Home Assistant first; the tool writes directly into the database.
- Check the preview: the counters of the Venus (registers 33000/33002) have the same value in both integrations, so the total continues without a jump.
- Compare the sign of power sensors: the SLEMS AC power is positive when discharging.
- Afterwards replace the old sensors in the energy dashboard with the SLEMS sensors and delete the old entities once everything looks right.
For batteries that report their cell voltages (Marstek Venus E 3.0), SLEMS shows the Cell delta (highest minus lowest cell voltage). With LFP cells the live value is only meaningful near full charge: in the middle of the charge the voltage curve is so flat that unequal cells show almost the same voltage. SLEMS therefore records the Cell delta at top of charge: after the highest cell reached 3.60 V or the BMS ended the charge at 100 %, and the battery then rested for 60 seconds (standby, including the about 13 W a Venus draws itself). It is measured once per charge: while the battery stands full the cells relax and the delta keeps falling without the balance getting better, so the next measurement follows only after the battery was discharged out of the top range (highest cell below 3.49 V); after a restart of SLEMS, too. The curve is steep there; Marstek cells typically show about 180 mV from the factory, which is normal. Status: below 200 mV good, below 230 mV minor, below 250 mV moderate, otherwise high imbalance. From 230 mV the dashboard recommends active cell balancing.
Active cell balancing (switch Active cell balancing, or the button in the dashboard) follows the Omnibattery balancing blueprint. It can only be started in operating mode active:
- If the battery is discharging, it first hands over smoothly (as when it is disabled). It then leaves the normal planning; the other batteries take over.
- It charges until the highest cell reaches 3.49 V, with the PV surplus (before the other batteries), at least 95 W. Without enough surplus the other batteries discharge to cover the 95 W.
- It charges with 95 W until the highest cell reaches 3.60 V, stands by for 60 seconds and measures the cell delta.
- Otherwise it discharges with 200 W to the retry voltage (3.49 V) and repeats from step 3. If the BMS refuses to charge (less than 30 W instead of 95 W, e.g. because it reports full at about 3.55 V), it does not measure (the delta below 3.60 V is smaller and not comparable), discharges to the retry voltage (3.49 V, or 10 mV below the voltage it refused at) and tries again.
- It discharges with 200 W to 3.48 V and ends when the delta is in the normal range (at most 190 mV), when it has not fallen by 2 mV for 6 hours, or after 24 hours.
The BMS bleeds the high cells passively, only a few mV per day; a run lowers a large delta step by step but does not reach the 0 mV of a lab charger. If the last measurement is already in the normal range, the dashboard says so before the start.
The discharge of the balancing battery is fed into the grid; the other batteries do not store it (they keep charging only if they charge anyway). Its expected charge is taken into account in the expected PV surplus and in grid friendly charging. It stops with an error if the battery cannot be read or the final discharge has not finished 2 hours after the 24 hours; it pauses outside operating mode active and continues after a restart of Home Assistant. When it ends, the battery is handed back to its own logic and then returns to the normal planning. The sensor Cell balancing phase shows the phase and the result of the last run.
The self-test checks whether a controlled battery does what SLEMS commands and whether its values are right. It is meant above all for batteries through Home Assistant entities, where sign, units and delays of the integration often differ from what is expected. When adding a battery, Run a self-test after saving is preselected; it starts as soon as SLEMS is in operating mode Active. It can be started at any time from the battery menu (⋮ → Run self-test) or with the switch Self-test.
Steps, about 5–10 minutes together:
- A discharging battery first hands over smoothly.
- 60 seconds of rest (0 W): the reference.
- Charging with a quarter of the smaller maximum power, at least 300 W, at most 800 W, until smart meter and battery show at least half of it, then 45 seconds more and until the charge counter moved (at most 4 minutes).
- 60 seconds of rest, then discharging like the charging.
- Hand-back to the battery's own logic, then normal planning.
If the battery may not charge right now (e.g. full) or not discharge (empty), that step is left out. While measuring, the other batteries and the consumers keep their last set points, so the smart meter shows the effect of the tested battery alone; a little energy may come from the grid or go into it meanwhile. SLEMS also takes the measured power of the other batteries out.
Checked are:
- Effect at the smart meter: does it move by at least half of the command in the right direction? If it does not move, the command does not arrive (wrong entity or register, remote control not enabled, battery not behind the smart meter); the other way round: the set point is inverted.
- Sign and size of the battery power: does the reported power change like the smart meter? Finds an inverted sign and a wrong factor (e.g. kW instead of W); a smaller difference points to the DC instead of the AC power.
- Response time until the effect at the smart meter (above 60 seconds: slow).
- Energy counters: the charge counter rises while charging, the discharge counter while discharging, not the other one and not by a multiple. Coarse counters that do not move in the short test are no error.
- State of charge: between 0 and 100 %, without jumps, not against the direction.
- Hand-back to its own logic.
If the house consumption changes a lot during the rest, the checks at the smart meter are unclear instead of failed; repeat the test at a quieter time then. The result appears as a notification, on the battery card (if something is conspicuous or wrong) and with an explanation per check under ⋮ → Details; the sensor Self-test result keeps it. It stops outside operating mode Active, with paused communication, when the smart meter does not report or the battery cannot be read for 30 seconds; a restart of Home Assistant ends it too. Only one self-test runs at a time, not during a cell balancing run.
During a firmware update of a Marstek battery there must be no Modbus communication at all. The menu (⋮) of a battery card offers Pause communication (firmware update): SLEMS hands the battery back to its own logic, closes the connection and does not read or send anything for the Communication pause duration (default 20 minutes; switch Communication paused). Afterwards it reconnects by itself; Resume ends the pause earlier, Extend pause adds the pause duration to a running pause (as does switching Communication paused on again, e.g. in an automation). Meanwhile the battery is treated like a disabled one. If the battery itself reports a running firmware update (state OTA update), SLEMS pauses automatically; as this is only noticed with the next poll, pause manually before an update.
The same menu enables or disables the battery, starts or cancels the cell balancing and opens Details: model, device name, firmware versions (EMS, VMS, BMS, communication module; sensor Firmware), MAC address, capacity, charge cycles, the total charged and discharged energy, the last full charge and when the cell delta was last measured. Open device in Home Assistant leads to the device page of the battery with all its entities.
The last full charge (sensor Last full charge) is the moment the battery last reached the top: the highest cell at the charge stop voltage, the SoC the BMS reports when full, or the BMS ending the charge near the top (it takes nothing for 2 minutes although SLEMS commands at least 100 W, from 98 % or 3.45 V on), also if it was discharged again right away. A new full charge counts once the battery has left the top (highest cell below 3.40 V, without cell voltages below 97 %). LFP batteries recalibrate their state of charge only when full, so it should happen regularly.
Regular full charge (settings group of the same name, on by default): a battery not full for longer than Full charge at the latest every (default 7 days), or never full since SLEMS records it, is charged first until it was full once. Only one battery at a time, the one whose last full charge is the oldest (never full first, then by name). The split between batteries and consumers does not change; the battery only gets the charge power before the other batteries. For this it may exceed its maximum SoC once; afterwards the limit applies again. If it does not get full for lack of PV, it stays first the next days. When discharging it is spared while all other batteries have more than 50 % and can deliver the power, so it starts the next day higher. Once full it rests 90 seconds, so the cell delta at the top is measured. Its card shows full charge due meanwhile; after 14 days without a full charge the overview names the battery.
Every controllable battery has these settings (dashboard: Settings):
- Minimum state of charge (default 12 %) and Maximum state of charge (default 100 %): SLEMS does not discharge at or below the minimum and does not charge at or above the maximum (with 100 % the BMS ends the charge). After reaching a limit the battery is used again 2 % away from it, because the resting SoC rebounds after a load. The maximum counts as "full" for grid friendly charging, the charge secured check and the projection; the minimum is the lowest target of the night discharge. Active cell balancing ignores the SoC window (it needs the top of the charge).
- Charge power limit and Discharge power limit (default: the maximum of the battery), e.g. 800 W for a plug-in system.
Temperature charge limit (off by default, after Omnibattery) limits the charge power by the battery temperature: above Charge derating temperature (40 °C) it decreases linearly across Charge derating range (10 °C) down to Charge power at high temperature (40 %); at or below Minimum charging temperature (0 °C) there is no charging, and within 5 °C above it the power rises to full again. The Venus reports its internal temperature, not the cell temperature; the BMS keeps its own protection. The sensors Allowed charge power and Allowed discharge power show the current limit and its reason.
Near the top of the charge SLEMS charges gently (always, after Omnibattery's
full charge voltage taper): once the highest cell reaches 3.48 V a battery
charges with at most 200 W until the cell falls below 3.44 V again. At a low
current the BMS balances the cells passively before the highest cell ends the
charge, so the batteries get really full with a smaller cell delta, and the
cells see less voltage peak and heat. It only affects the last one or two
percent; the surplus meanwhile goes to the other batteries or the consumers.
The sensor Allowed charge power has the reason top; batteries without cell
voltages are not limited.
In operating mode active SLEMS checks, like Omnibattery, whether every battery delivers the commanded power. A battery that delivers less than 10 % of a command of at least 100 W (after 30 s in that direction) three polls in a row first gets all control registers written again; if that does not help, it is excluded for 5 minutes (like a disabled battery, handed back to its own logic, the others take over) and then retried. A full battery that stops charging or a battery at 20 % or less that stops discharging does not count (the BMS protects it). The Venus also reads its control registers back after every complete write (first command and every 60 s); a write that is not confirmed counts as well. The binary sensor Not responding and the dashboard show an excluded battery.
Every consumer needs its own power and energy sensor.
Which consumers to add: the ones SLEMS controls (heating rod, wallbox, dehumidifier, …) and heat pumps (their consumption is forecast from the weather). Adding other devices only to measure them, e.g. a washing machine or a dishwasher, currently does not improve the planning: their consumption is already part of the house consumption, and its forecast (a profile per weekday and hour) contains their average use. They only get their own card and box in the energy flow.
- Included in smart meter: enable if the consumer is behind the smart meter (its consumption is already part of the grid power). Disable for consumers on a separate supply.
- Show in the energy flow (default on): off hides the consumer's box in the energy flow of the dashboard; its consumption still counts in the house, and the consumer card still shows it.
- Type: heat pump (heating and hot water, forecast from the weather), heating rod (e.g. hot water in summer), wallbox (electric vehicle) or other. Heat pump and heating rod may run at the same time. A wallbox is never part of the house consumption forecast (also when only measured); its defaults are current control, 6–16 A, 3 phases, 5 minutes minimum runtime and pause and battery support automatic.
- Control: none (measurement only), on/off via a switch, a power set point via a number entity in W, or a current set point in A. For controlled consumers an entity can be selected that blocks them externally (SLEMS leaves the consumer alone while a switch or binary sensor is on, or while a water heater is in operation mode off), a priority (1 = highest) and optionally a minimum runtime and a minimum pause. For on/off consumers a rough estimate of the power when on is enough if Use learned values is on; rather too low than too high, because SLEMS only learns while it runs the consumer.
- Avoid short runs (e.g. a device with a compressor): SLEMS switches the consumer on only when the forecast surplus lasts for a whole run (its minimum runtime, 15 minutes without one, or what its daily target still needs if less), and keeps it running through dips of the surplus for up to 5 minutes (the batteries or the grid bridge them). Forced runs of a daily target are not affected. Set a minimum runtime and pause as well.
- Own thermostat (no setting, observed): a consumer that draws nothing although commanded counts as saturated for 15 minutes and keeps its last command (shown as Planned with "held"); once it draws half of that command again, SLEMS controls it again at once. If its own thermostat switches it off and on while it is commanded (e.g. a heating rod that measures at the element: two pauses of 30 s to 10 min within 30 days), SLEMS keeps controlling it instead: during a pause (no power for 2 response times, 10–60 s) the batteries get its unused power, and as soon as it draws again it gets it back (shown as thermostat pause).
- Control active (switch per controllable consumer, also on its card in the dashboard): off means SLEMS only measures the consumer. Switching it off in operating mode active sets it to 0 W (or off) once; afterwards SLEMS leaves it alone and plans it like an uncontrolled load: its daily target is paused and nothing of it enters the forecast (the card shows control off); if it runs by itself, the control sees it live.
For wallboxes and evcc loadpoints: SLEMS plans in watts and sends whole amperes, rounded down so the charging stays within the planned power.
- Minimum / maximum current (default 6 / 16 A): below the minimum the consumer is stopped. Its power range is current × voltage × phases (3 phases: 4.1–11 kW, 1 phase: 1.4–3.7 kW); one ampere is 230 W per phase.
- Phases fixed (1 or 3) or an entity of the active phases (1 or 3, e.g. of a wallbox or evcc loadpoint switching phases itself); the power range follows it. SLEMS does not switch phases itself.
- Voltage (default 230 V per phase).
- Start/stop entity (optional): a switch, or a select with the options for on and off (asked in the next step), e.g. the mode of an evcc loadpoint (now / off). Without it SLEMS stops by setting the lowest current the control entity takes (0 A if allowed).
- The control entity is a number entity in A or a select with ampere options.
- With evcc (ha-evcc): the control entity is the maximum charging current of the loadpoint (a select), the phases entity its active phases. Step by step with screenshots: Connecting a wallbox with evcc. Without a start/stop entity evcc decides itself when to start and stop (e.g. in its PV mode) and SLEMS only caps the current; with the charge mode as start/stop entity SLEMS controls the charging fully, so its battery support and forecasts decide. The card shows the planned power with amperes and phases, e.g. 4,140 W (6 A, 3 phases).
Optional, up to two, e.g. the sensor of a boiler at the heating rod and one higher up.
- SLEMS learns from the mean of the sensors (and of each sensor) how much energy the storage takes per degree, from which temperature the thermostat starts cycling, its mean power while cycling and when it is full. Which sensor switches the thermostat and where they sit does not matter.
- From three heating runs and two starts of the cycling on, the consumer card shows how much the storage can still take, and the feed-in cap plans the consumer only with 80 % of that.
- Its box in the energy flow shows the temperature of the sensor chosen for the daily target (the mean by default).
Select per consumer behind the smart meter (also measured only ones), on its card under Show settings: how far the batteries may cover it when there is no PV surplus.
- Always (default): like any other load.
- Never: its power always comes from the grid; the batteries cover only the rest of the house.
- Automatic: the batteries cover it only with the energy they can spare, the budget: the lowest stored energy until the next charge from PV (from the forecast of house consumption and PV, without night discharge) minus the minimum state of charge, the morning reserve and the safety buffer; with import peak shaving also its SoC threshold. "Until the next charge" is the coming morning at night and the morning after the coming night during a surplus. The budget is computed anew from the current state of charge all the time and shrinks while the batteries cover the consumer; once used up the consumer runs from the grid until the budget is back at 0.2 kWh. Several consumers on automatic share the budget. Energy the night discharge would feed in may go to them instead.
The PV surplus is not affected, import peak shaving still covers peaks, and a
forced run of a daily target with the source battery may use the batteries.
The forced runs of daily targets with the source grid follow the setting in
the forecast chart as well (on automatic until the next charge from PV;
later ones are planned like always); measured only consumers are part of the
consumption forecast, there the setting acts only in the control. The card
shows the setting with the budget and whether the batteries cover the
consumer right now; while it runs from the grid for this reason, its box in
the energy flow carries the badge grid. The budget is also the attribute
support_budget_kwh of Stored energy total.
Useful for loads that would empty the batteries in the evening: a sauna, an instantaneous water heater, a heating rod with the source grid, later a wallbox.
Select per controlled consumer, on its card in the dashboard under Feed-in cap while the cap is on. Within a role the priority decides. Applies only while Control active is on (greyed out otherwise). See Feed-in cap.
- Supporting: gets no other surplus while the feed-in cap is on, only the surplus above the limit the batteries cannot absorb; if the forecast shows that a peak does not fit into the batteries, it runs from the start of the peak so its power is used over the whole peak.
- Normal (default): surplus as without the feed-in cap; above the limit it takes what the batteries and the supporting consumers cannot, before it is curtailed.
- Never: surplus as without the feed-in cap, never the surplus above the limit.
Per controlled consumer, on its card under Daily target.
-
Kind: runtime (time it draws power), enabled time (time SLEMS has it switched on, for devices with their own control such as a dehumidifier with a hygrostat), energy (kWh) or temperature (with temperature sensors: minimum and target temperature of its storage; with two sensors Sensor chooses the mean, sensor 1 or sensor 2, in the order of the consumer's configuration).
-
Period: counted from one deadline (Until, default 22:00, also across midnight) to the next and met from the surplus first.
-
Earliest start (runtime, enabled time, energy): before this time SLEMS does not switch the consumer on, not even with surplus (e.g. a dehumidifier only from 10:00); the latest start is never before it. If the hours (or the energy at full power) do not fit between the earliest start and the deadline, the target settings show a warning.
-
No power: if a consumer with a daily target draws no power on 3 days in a row although SLEMS switched it on (at least 30 minutes a day, less if the target or its window is shorter), its card and its box in the energy flow show a hint (switched off, fuse or broken?) until it draws power again.
-
Source decides what may cover the rest in time:
- surplus only (default; the target may be missed, then a notification says so – not if SLEMS could not control the consumer at some time of the period: operating mode not Active or its Control active switched off – or if it declined power because its own thermostat was satisfied (saturated or resting); if it was blocked externally, the notification names how long),
- surplus + batteries (from the latest start on the consumer runs regardless of the surplus as long as the batteries can deliver, a power controlled one at most with their discharge power),
- surplus + batteries + grid.
The latest start is the deadline minus the remaining time × 1.2 minus 10 minutes.
-
Before the batteries when short: the consumer gets the surplus before the batteries if the forecast surplus until the deadline is short for the rest of its target plus filling the batteries.
-
Temperature: below the minimum the consumer always gets the surplus before the batteries (forced from the latest start, estimated with the learned energy per degree, otherwise 2 hours before the deadline); at the target temperature it is off for the rest of the day; if a higher target temperature is set later in the day, it heats on. A temperature target applies to the calendar day: after the deadline the consumer stays off until midnight (waits until 00:00), also with surplus. If the temperature falls below the minimum again (e.g. after drawing hot water), the target is open again: up to the minimum with priority, then with the surplus up to the target. Choosing another sensor starts the target open again.
-
Display: the card shows the progress, e.g. 1.5 / 4 h · until 22:00 · forced from 19:30 · about 2.3 kWh to go, and the chips priority or forced while they apply; the consumer's box in the energy flow carries the same badge, and the strategy tile lists it (Before the batteries: …), since the batteries then only get what is left. The energy still needed is exact for an energy target; for a runtime or enabled time it is the remaining time at full power (less if the consumer's own thermostat stops it earlier); for a temperature target it is the way up to the target temperature with the learned energy per degree. That leaves out water draws and heat losses, so it is at least the mean daily energy of the consumer's last 7 days with consumption (at least 2) minus what it already got in the period (estimated from the last days); this estimate also applies while the energy per degree is not learned yet, without such days energy still being learned.
-
Planning: with a source beyond the surplus the planning counts the forced run as extra consumption from the latest start on, as if the surplus covered nothing more; the planned run shrinks as the surplus fills the target. The rest of the target the planning expects from the surplus: hour by hour it takes what is left after charging the batteries, in order of priority, from now (or the earliest start) until the deadline and at most at the consumer's power; the expected feed-in drops by it. The target of the following period is planned the same way (a temperature target with the daily energy of the last days), so Tomorrow shows it too. A controllable consumer without a daily target is expected to take its mean daily energy of the last days from the surplus (today what is left of it). Both appear in the day chart as Consumers (planned) and in the consumption forecast, the state of charge forecast and the night discharge. A consumer with the role Supporting is left out of the surplus part while the feed-in cap is on: the feed-in cap plans it with the surplus above the limit.
SLEMS adds the entry SLEMS to the Home Assistant sidebar.
- Energy flow between grid, PV, house, every battery (with its state of charge) and the consumers; the animated dots run in the direction of the flow, faster and on a thicker line the higher the power. The SLEMS logo in the middle opens a menu: the bad weather mode and the control details (status, control gain, control interval and averaging window, source and update interval of the smart meter, with Modbus its round trip, errors and the time on the entity today, and the battery response times).
- Key figures: status (problems first – smart meter without values, battery unreadable or not responding – otherwise the operating mode), strategy (a change shows once it lasted 30 seconds; the control switches at once), state of charge, feed-in limit, stored energy and capacity, forecasts, and the expected export today: the export measured since midnight plus the export the plan still expects (the blue line of the chart).
- Forecast chart (mean power per half hour in kW):
- Today shows PV and consumption forecast (dashed), the measured values so far (solid), the expected and the measured feed-in into the grid (blue; the expected one from the plan, including night discharge, at most the feed-in cap), the planned battery charging (light bars) and the measured charging (solid bars), the planned load of the consumers' daily targets (pink, dashed; part of the consumption forecast), plus the projected total state of charge (dashed) and the measured one (solid) with their scale in % on the right.
- Tomorrow shows the forecasts, planned charging and state of charge of the next day, continued from today's projection.
- The projection follows the planning: charging only with the planned surplus, deficits covered by the batteries, import peak shaving and night discharge if enabled.
- Hovering (on a phone: tapping, a tap elsewhere closes it) shows the values of a half hour; selecting an entry of the legend hides or shows that series (the scale follows the series shown; the browser keeps the choice; PV above the limit of the feed-in cap is hidden until switched on); Show table switches to a table.
- Price chart (only with a tariff whose prices change over the day, with market prices or with price aware control), below the forecast chart on the same time axis: per quarter hour the price of an imported kWh with the current tariff and the feed-in credit (ct/kWh incl. VAT, with time windows and dynamic prices, without fixed fees) and the market price if market prices are fetched, with its source.
State of charge, stored energy and capacity (kWh), power on the grid side (AC) with its direction, the SLEMS set point, efficiency, state and the Enabled switch of every battery (disabling asks for confirmation), the cell delta with its balance status, a recommendation for active cell balancing and the phase of a running one.
One card per consumer, collapsed to the important values (measured and planned power, progress of the daily target) and expanded with Show settings (the browser keeps the choice). Measured and planned power, blocked/saturated state, the learned response times for switching on and off (own sensor and at the meter; switching on includes a start delay of the device, e.g. a compressor) and the Control active switch.
Try other settings without changing anything.
- What can be changed: next to the day chart (today from now on or tomorrow) grid friendly charging, night discharge, import peak shaving and the feed-in cap can be switched on and off; their values appear below each switch as in the settings. The batteries (capacity, minimum/maximum state of charge, charge and discharge power), the night discharge buffer, the maximum grid export while discharging and the PV and consumption forecasts (±%) can be changed too.
- Result: SLEMS calculates the day plans like the real ones, from the current state of charge and the current forecasts; the plan with the current settings is shown grey dotted for comparison, key figures (feed-in, grid import, highest import and feed-in, curtailed energy, state of charge at midnight) side by side below.
- Nothing is saved or used for the control; every visit starts with the current settings.
- Today is simulated from now on (the values before are measured); in the afternoon a note suggests Tomorrow for a whole simulated day.
- The daily targets of the consumers are planned as in the real plan; otherwise consumers controlled by SLEMS and the battery priority (which acts in the real-time distribution) are not simulated.
Tariff comparison: with tariffs the simulation tab shows per month of the last year (and the current month to date) the recorded grid import and feed-in and, per tariff including VAT, the costs of the import and the credit for the feed-in (less its fees; a switch shows both summed), below each comparison tariff its difference to the current one (green better, red worse). The comparison tariffs can be shown or hidden by selecting their names (remembered in the browser). It is a passive comparison: the recorded energy priced differently, not what SLEMS would have done with another tariff (e.g. charging the batteries in cheap hours). Dynamic tariffs use the stored market prices; energy without a market price is marked. With batteries a line below the costs of a tariff adds an estimate of what the price aware control would have saved: the recorded hourly house consumption and PV are played through a simple battery model, once as usual and once planned like the price aware control (with charging from the grid if it is switched on). The plan knows consumption and PV exactly, so the estimate is an upper bound. Tariffs where the control saves nothing (a fixed price) have no such line.
All settings grouped and editable directly; the Control card also shows the learned values (current control gain, smart meter update interval, battery response time).
Selecting a value (tile, box in the energy flow, row of a card) opens the Home Assistant dialog of its entity with history and settings.
The dashboard follows the language and the light/dark theme of Home Assistant and works on phones (with little space the batteries in the energy flow are shown one below the other).
The entity SLEMS Operating mode switches between:
- Off – nothing is planned or sent.
- Simulation – forecasts and plans are computed and shown, but no command is sent to batteries or consumers. This is the default.
- Active – plans are executed: SLEMS sends set points to the batteries and switches/sets the consumers. It reacts to every change of the smart meter. The entity Control status shows whether the control is active or paused because the smart meter did not report for a while (60 s or ten update intervals; the batteries then follow their own logic until the meter is back).
When bad weather is coming, the switch Bad weather mode (also in the menu of the SLEMS logo in the energy flow) stores as much of today's surplus as possible:
- The batteries charge every surplus at once instead of charging grid friendly, and the night discharge is off.
- The target grid surplus, the feed-in cap and the battery limits stay.
- It ends by itself in the evening: at the end of the last hour in which the
PV forecast is above the consumption forecast (without such an hour at the
end of the PV production), recomputed with every new forecast. Switched on
after that moment, e.g. in the evening before a rainy day, it lasts until
the evening of the next day, so the night discharge of this night is off as
well. The attribute
untilshows the end. - While it is on, the logo carries a rain cloud; the forecast chart and the expected export follow it.
In operating mode active SLEMS reacts to every new value of the smart meter:
- From the energy balance it calculates which battery power would bring the grid power exactly to the target (e.g. 100 W export while charging).
- It only counts battery commands that the smart meter can already show. A new command needs some time until it appears in the meter value; SLEMS learns this response time and does not count a command twice. The same applies to the controlled consumers: until a command reaches the meter (response time at the meter, learned per consumer) the power before it counts, afterwards the measured power, or the commanded one while the consumer's own sensor has not caught up yet. So meter value, batteries and consumers always describe the same moment.
- It does not jump to the calculated value at once but moves a share of the way per cycle, the control gain. With 0.5, half of the remaining deviation is corrected per cycle. A high gain reacts faster, a too high gain overshoots and makes the grid power swing back and forth.
Automatic control gain (switch, on by default): SLEMS watches its own corrections and adjusts the gain between 0.2 and 0.9:
- If the corrections change direction several times in a row without dying out, the control swings: the gain is lowered at once (× 0.8).
- If the grid power approaches the target only slowly over many cycles without ever overshooting, the gain is raised in small steps (+ 0.05).
- After each change SLEMS waits 30 seconds to see its effect. Normal load changes (a kettle, a cloud) are not mistaken for swinging. The learned value is kept across restarts.
Control gain is the start value of the automatic adjustment; changing it restarts the adjustment from the new value. With the automatic adjustment switched off, Control gain is used as a fixed value. Control interval (default 1 s) limits how often SLEMS sends commands.
Diagnostic sensors show what SLEMS has learned:
| Sensor | Meaning |
|---|---|
| Current control gain | gain used right now |
| Smart meter update interval | how often the smart meter reports; attribute source: Modbus or entity |
| Battery response time | time from a battery command until the smart meter shows it, for all batteries together; per battery (from steps it makes mostly alone) in Details of the battery, used by the control once learned |
Planned power of a consumer, attribute response_time_s |
time from a command until the consumer's own power sensor reacts |
Switch the automatic adjustment off only if the gain keeps changing noticeably, e.g. because the smart meter reports very irregularly; then set a fixed value (0.3–0.5 is a good start).
All options are optional and can be combined. The charts show the same example with and without each option: 8 kWp PV on a sunny day, a household with morning and evening peaks, a 10 kWh battery, from 18:00 until midnight of the next day. They are calculated with the SLEMS state of charge projection (hourly means), so they show how SLEMS plans; the real curves depend on your forecasts. Top: PV production and consumption (the same with and without the option); middle: total state of charge; bottom: grid power (+ import / − export); grey dashed without, coloured with the option.
Grid friendly charging (on by default)
Without it the batteries are full before noon and the whole midday peak goes to the grid (here 5.7 kW). With it they charge with the surplus above a feed-in limit and are still full in the afternoon; the peak drops to about 4.4 kW. Useful whenever many PV systems feed in at the same time (grid, energy community). Switch it off if the batteries should be full as early as possible, e.g. for backup power.
Night discharge
Energy still in the batteries in the morning is fed in over night, down to a reserve that the PV forecast can refill the next day (here Morning reserve 10 %: about 2.9 kWh are fed in over night, and 3.2 kWh less at noon, because the batteries have more room for the PV). Useful if the batteries are still well charged in the morning (large battery, low night consumption, summer):
- In an energy community your energy is more likely to find a buyer at night: during the day most members produce themselves, at night they consume. Night discharge shifts part of your surplus from noon to the night.
- It works well together with the feed-in cap: the batteries start the day with room for the energy above the limit, so SLEMS rarely has to feed in shortly before the peak.
The energy fed in at night passes the battery twice (charge and discharge losses, about 10 %), and less energy is left for a power outage until the next charge. Switch it off if the batteries are meant as a backup supply.
Import peak shaving (useful on days with little PV, e.g. in winter)
Without it the battery covers everything until it is empty in the evening; the morning peak then comes from the grid in full (here 2.1 kW). With it, below the state of charge threshold the battery only covers the power above the import limit: the base load comes from the grid, the battery keeps its energy for the peaks (here 1.5 kW at most). Some peaks become higher than without (here at 19:00, 1.5 instead of 0.4 kW, because the battery no longer covers everything), but none goes above the import limit, so the highest peak drops. Useful with a power based tariff or grid fee, or if the grid connection is weak. Somewhat more energy comes from the grid (here 1 kWh), but it is still in the battery at the end: the peaks are lower, the energy balance stays about the same.
Feed-in cap (if the feed-in is limited, e.g. to 60 % of the peak power)
Without it the batteries are full at noon and the inverter curtails everything above the limit (red, here 7.2 kWh at a limit of 45 %). With it SLEMS keeps enough room free; here the night discharge makes the room and the batteries absorb the energy above the limit. Needed whenever your grid operator limits the feed-in; it takes precedence over the other options.
Charging as soon as there is surplus fills the batteries in the morning, and the PV feed-in peak around noon then goes to the grid in full. With Grid friendly charging (switch, on by default) SLEMS shifts charging into the peak:
- From the PV and consumption forecasts it calculates a Feed-in limit: the
highest grid export at which the surplus above it still fills the batteries
by the end of the day (charge losses, maximum charge power and Grid
friendly charging buffer included; default 1 kWh, a larger buffer lowers
the limit and makes the batteries full earlier and more reliably when the
forecast is too optimistic). Without a limit the overview tile shows the
reason: off (grid friendly charging switched off), none – charge at once
(the surplus is not enough) or no forecast; the sensor then has no value
and the reason in its attribute
reason. - The batteries only charge with the surplus above this limit; below it the power goes to the consumers or to the grid. The highest hours of the day are cut, wherever the clouds put them.
- The limit is recalculated continuously from the current state of charge and the remaining forecast. If charging falls behind (e.g. more clouds than forecast), the limit drops by itself.
- The PV forecast is corrected with today's actual production (diagnostic sensor PV forecast correction: the ratio of the production to the forecast until now, 50–120 %). A morning says little about the whole day (fog, a hill shading the first hours), so the ratio is applied with a weight: the current hour at 80 %, fading out over two hours, and the rest of the day only once 15 % of the day's forecast energy has passed, fully from 50 % on (attributes of the sensor). After a restart SLEMS takes the production so far from the statistics of the PV sensor, so nothing is lost.
- As long as the charge is not secured (state of charge below Battery priority below state of charge or the forecast is not sufficient), SLEMS charges at once as before.
How much of the peak can be absorbed depends on the battery size compared to the day's surplus: on a clear summer day with a large surplus a 10 kWh battery takes about the top kilowatt of the peak, on days with less surplus a much larger share.
Some grid operators or regulations only allow a PV system to feed in a share of its peak power (e.g. 60 %); the inverter curtails everything above it. With Feed-in cap (switch, off by default) SLEMS stores that energy in the batteries instead of losing it. The limit is PV peak power (kWp) × Feed-in cap limit (%), measured at the grid connection point (grid export, after the house consumption).
- Planning: from the PV forecast in its finest resolution (15/30/60 min, so short peaks are not averaged away) and the consumption forecast, SLEMS calculates until the end of tomorrow how much energy lies above the limit and how much free space the batteries need for it. Several peaks per day (clouds in between) and peaks today and tomorrow are covered: a cloud dip or the night in between, in which the batteries supply the house, makes room again; a surplus below the limit does not.
- Buffer: Feed-in cap buffer (default +20 %, negative values plan with less) is added to the energy to absorb. With Automatic feed-in cap buffer SLEMS uses the recorded PV forecast errors instead (see Forecast accuracy): of the days with more PV than forecast, the underestimation not exceeded on 80 % of them raises the PV forecast. This needs 14 recorded days; until then the fixed buffer applies. In addition a fixed minimum buffer of 5 % of the PV peak power as energy of one hour (0.5 kWh at 10 kWp) stays free per peak in any case: it covers errors in the timing and height of a peak that the daily forecast errors do not show, and small peaks for which the percentage buffer is tiny. The settings show the limit, the buffer in use and the minimum buffer.
- Making room: charging with surplus below the limit only happens as long as the space needed later stays free; above the limit the batteries always charge. The night discharge (if enabled) stops early enough to leave the space. If the house consumption and the night discharge are not enough, SLEMS feeds battery energy into the grid before the peak, as late as possible: it is planned to be finished one hour before the peak with 70 % of the possible power, never above the limit. For this it may exceed Maximum grid export while discharging.
- Order during the peak: the surplus above the limit goes to the batteries (regardless of battery priority, battery share and grid friendly charging), then to the consumers with the role Supporting, then to those with Normal, and only the rest is curtailed. If the forecast shows that a peak does not fit into the batteries (too small, or too late to make room, with the buffers), SLEMS plans the supporting consumers from the start of the peak for the part that does not fit: a consumer with little power would otherwise only start when the batteries are full and could then take far less than the surplus. With temperature sensors it plans them only as far as their storage can still take energy. The feed-in cap takes precedence over grid friendly charging (its feed-in limit never lies above the cap), night discharge and battery priority; the peak shaving threshold stays a floor for feeding in.
- Overview: the tile Feed-in cap shows the next peak, the energy the batteries have to absorb and, if needed, the energy to feed in before it and by when. The day chart shows the PV limit of the feed-in cap as a grey dashed line: expected consumption + limit, the PV power above which the export would exceed the limit (the limit applies after the house consumption, so the line follows the consumption forecast). The energy above it is shown as a bar on that line; in red the part that is still lost according to the plan, because the batteries are full or charge too slowly (the reason is shown in the tooltip; consumers set to take surplus above the limit are taken into account). The key figure Curtailed in the simulation is the same energy.
- Warnings (overview and notifications): batteries too small for the space needed, not enough time or power left to feed in before the peak, charge power too low for the surplus above the limit, and feed-in above the limit for more than 5 minutes. Batteries too small means the forecast itself does not fit; if only the safety buffer does not fit completely, the overview shows the note forecast within the buffer zone instead (no notification). Energy that does not fit into the batteries (too small, or too late to make room) does not count as a problem as far as the supporting and normal consumers can take it during the peak; the overview then shows the note consumers take the rest with the energy and the consumers. Batteries left out of the planning (cell balancing, communication paused, disabled, not responding) are named in the texts.
Sensors: Feed-in cap energy to absorb (on the day of the next peak, with the peaks, the space needed, the export plan and the buffer as attributes) and Feed-in cap export before the peak.
Each of these values has a switch … automatic (or Use learned …). SLEMS always learns, whatever the switch; it only decides what is used. Off, the value you set applies; on, SLEMS uses the learned value as soon as there is enough data, until then still yours. The settings show the learned value (learned) or the note that there is not enough data yet; the diagnostic sensor Learned values in use has all learned values as attributes.
| Value | Learned from | Needs |
|---|---|---|
| Grid friendly charging buffer | recorded PV forecasts: of the days with less PV than forecast the shortfall not exceeded on 80 % of them, applied to the PV still expected today | 14 recorded days |
| Charge secured safety buffer (also the night discharge target) | the same for the PV plus the consumption forecast being too low (backtest), applied to the rest of the day or the next 24 hours; while only one part is learned, the larger of it and the set buffer | 14 PV days, 7 consumption days |
| Grid surplus targets while charging and discharging | how far the grid power swings towards import while the batteries control it; charging: the target keeps the grid on the export side 90 % of the time (20–1000 W); discharging: the grid swings around the target, half of the time each side (−100 to 300 W), as a short import costs little there but a permanent export gives battery energy away | some controlling in operating mode active |
| Control interval and surplus averaging window | the learned report interval of the smart meter (0.8 × and 3 ×) | a few meter reports |
| Usable capacity (per battery, Use learned capacity) | charge and discharge legs over at least 20 % state of charge: DC energy / change of the state of charge (legs with a jump of the state of charge are discarded), median of the last ten | three legs |
| Morning reserve (Morning reserve coverage sets how cautious; shown only while the reserve is automatic) | the morning gap: energy the house needed from battery or grid between the planned takeover of PV (end of the night discharge) and the real one (PV covering the consumption for 15 minutes), in % of the day's forecast consumption; the reserve covers the chosen share of the mornings (90 % = 9 of 10), above 100 % the largest gap times the value (110 % = 10 % more than the worst morning) | 14 measured mornings (also measured while the night discharge is off) |
| Power and thermostat of a consumer (per consumer, Use learned values) | the power while switched on (on/off consumers: replaces the nominal power; power controlled consumers: the typical power at full load, measured while commanded at ≥ 90 % of the maximum power for at least 15 s or twice its response time, used for planning: forecast, daily target, feed-in cap; it is still commanded up to its maximum power) and pauses of its own thermostat while it is commanded, lasting 30 s to 10 min (two within 30 days: its own thermostat cycles, see Own thermostat; applies also without Use learned values; longer pauses, e.g. a dehumidifier at its target humidity, do not count) | 30 samples, two pauses |
- Vacation (switch) – the household is away; switch manually or by an automation.
- Battery priority below state of charge (default 30 %), Charge secured safety buffer (default 1 kWh) and Battery share when charge is secured (default 75 %) – the batteries get all surplus until their charge is secured: the state of charge is above the threshold and the expected PV surplus of the day covers the energy to fill them plus the safety buffer. Afterwards the surplus is split, the consumers' share is distributed by priority; a running on/off consumer keeps its power before power controlled consumers of higher priority (they take less instead, so the on/off one is not switched off and on again). Power one side cannot use goes to the other.
- Grid surplus target while charging (0–5000 W, default 100 W) – the batteries only charge from the surplus above this value.
- Grid surplus target while discharging (−1000…+1000 W, default 50 W; positive = export, negative = import) – the grid power the discharging batteries aim at. Between the two targets the batteries stay idle.
- Maximum grid export while discharging (0 up to the sum of the maximum discharge power of all batteries, default 5000 W) – discharging never causes more export than this. 0 W means never feeding battery energy into the grid, the maximum switches the limit off. Below the grid surplus target while discharging it wins (the dashboard shows a note).
- Morning reserve (default 25 % of tomorrow's forecast consumption): energy that should remain above the minimum state of charge in the morning, for mornings when PV takes over later than forecast; used by the night discharge and the battery support.
- Night discharge (switch, off by default) – over night the batteries discharge evenly down to the reserve (usable energy above the minimum state of charge of the batteries) until PV production exceeds the consumption again, ignoring the discharge grid target (the maximum grid export still applies). If tomorrow's PV forecast cannot refill the batteries from the reserve, a higher reserve is kept; the refill counts per hour at most the charge power of the batteries, and the surplus that daily targets of consumers are expected to take that day must fit besides it. Requires the consumption forecast.
- Surplus averaging window (0–300 s, default 5 s, 0 = off) – the grid power is averaged; the less favourable of average and current value is used, so the control does not overshoot with fluctuating PV.
- Import peak shaving (switch) – off by default. When enabled and the total state of charge is at or below Peak shaving state of charge threshold, the batteries only discharge to keep the grid import below Peak shaving grid import limit. The threshold is an absolute state of charge but cannot be set below the minimum state of charge of the batteries; below 20 % the settings show how much is left above the minimum. With Automatic peak shaving limit SLEMS calculates the import limit itself: the lowest one for which the expected energy above it, until PV refills the batteries (the forecast surplus adds up to the energy back to the threshold, so a little surplus on a rainy day does not count), fits into the usable energy above the minimum state of charge minus Peak shaving safety reserve (default 20 %). The expected energy comes from the 5 minute statistics of the house consumption of the last days, so short peaks such as an oven are included; the limit is recalculated continuously and rises when more is used than expected. Above the threshold it is calculated as if the threshold were reached, and during the day for the coming evening and night, so it shows the limit that will apply. In the settings the import limit then shows the calculated value (read only); the sensor Peak shaving import limit in effect shows the limit used.
Ongoing problems appear under Settings → Repairs and disappear by themselves when they are solved:
- a battery does not respond (excluded, see above),
- a battery could not be read for more than 5 minutes,
- a battery could not be handed back to its own logic for more than 5 minutes (it may still run with the last set point; SLEMS keeps trying, every release is confirmed by reading the battery back),
- the smart meter does not report while SLEMS is in operating mode active,
- the smart meter could not be read over Modbus for more than 5 minutes (SLEMS uses the entity meanwhile),
- the consumers behind the smart meter report clearly more power together than the whole house for more than 15 minutes (a consumer measures wrong or is not behind the meter; base load and consumption forecast are wrong meanwhile),
- the current tariff follows the market price while Home Assistant is set to another currency than euro (see market prices).
The dashboard also shows them: a red note on the battery card (cannot be read, not responding), in the energy flow and, for the smart meter, at the top of the overview. The end of an active cell balancing run (in the normal range, without further progress, after 24 hours or with an error) creates a notification with the cell delta before and after and the duration; cancelling it yourself does not.
For a problem report, Settings → Devices & services → SLEMS → ⋮ → Download diagnostics (or the same on a battery device) saves the configuration and the internal state as a file: measurements, plans, battery limits, the last register values, the state of the cell delta measurement and of a balancing run. IP and MAC addresses are removed. The warnings of the feed-in cap (batteries too small, not enough time to make room, charge power too low, feed-in above the limit, see Feed-in cap) are notifications too; they disappear by themselves when the problem is gone.
SLEMS is available in English and German. Home Assistant uses two different language settings:
- Entity names (e.g. House consumption, Operating mode, also the key figures in the dashboard) follow the server language under Settings → System → General. They are set when the integration loads, so reload SLEMS after changing it.
- Dialogs, menus, states (e.g. Simulation (read-only)) and the texts of the dashboard follow the language in the user profile.
If names stay in the wrong language after an update of SLEMS, restart Home
Assistant (translations are only read at startup) and reload the browser
without cache. Entity IDs such as sensor.slems_house_consumption keep the
language of their creation; only the displayed names change.
Possible extensions:
- Feedback from users with a real wallbox on the evcc guide.
- Wallbox with evcc (mode A) as comfortable as evcc itself: a daily target by the state of charge of the car ("80 % by 7:00", from evcc via ha-evcc), a switch to charge right away with full power (until unplugged or up to a state of charge) and targets that only apply once the car is plugged in.
- Batteries with an availability (e.g. "car plugged in") and a reserve until a time of day: the basis for a car supplying the house (V2H).
- Learned presence of the car for the planning.
- Feeding in from the batteries also in the estimate of the tariff comparison.
- Tariff comparison with other hardware: what a larger battery, more charge power, another maximum state of charge or more PV would have brought in the recorded year (the battery model of the estimate with the settings of the simulation).
- Consumers preferred at negative prices (e.g. the heating rod).
- Price aware control: a more stable plan (changed only when clearly better).
- Estimated prices from the weather: the forecast of wind, solar and load of the bidding zone (Energy-Charts) moves the estimate; with them known exactly, the deviation of the last year would have dropped by about a third.
- Prices from a Home Assistant entity of the supplier (e.g. the Tibber integration, Octopus Germany, Ostrom): a line type with adapters for the common forecast formats, stating whether the price already includes the grid fees and levies.
- Daily targets of the consumers planned together with the batteries.
- Index tariffs (e.g. on the Austrian electricity price index ÖSPI): a line type with the supplier's formula, the monthly index values fetched (with consent) from the Austrian Energy Agency; templates for index tariffs too.
- Program devices (washing machine, dishwasher, dryer): learn the course of a program and add the rest of a running program to the forecast of the next hours (helps the evening and night planning); later possibly starting them with surplus if the device allows a remote start.
- Public holidays in the consumption forecast: a holiday at home planned like a weekend day, from a calendar of the Home Assistant integration Holiday for the own canton or state (else the national holidays of the country set in Home Assistant).
- Ongoing check of the batteries in normal operation: clean set point changes (one battery, no consumer switching, a quiet smart meter) compared with the smart meter and the reported power; after many consistent mismatches (e.g. a sign turned by an update of the integration) a repair issue suggests the self-test. First only counted in the diagnostics to set the limits with real data.
- Modbus profiles for batteries: a description of the registers (read values, steps to charge, discharge and release) that SLEMS uses through the Modbus connection of Home Assistant, shared with other integrations; profiles for known models ship with SLEMS, an own one is pasted as YAML (made with an AI prompt from the manual) and checked with the self-test. Experimental and next to the direct Venus driver, which stays the default.
- Further battery models via the driver interface.
See developers.md.