14 changes: 12 additions & 2 deletions ariston/nuos_split_device.py
Original file line number Diff line number Diff line change
Expand Up @@ -204,7 +204,14 @@ async def async_set_water_heater_reduced_temperature(self, temperature: float):
def set_water_heater_operation_mode(self, operation_mode: str):
"""Set water heater operation mode"""
self.api.set_nuos_mode(self.gw, NuosSplitOperativeMode[operation_mode])
self.data[NuosSplitProperties.MODE] = NuosSplitOperativeMode[
# The Nuos cloud payload exposes two distinct fields: `mode` (the
# plant mode shared with other Velis devices) and `opMode` (the
# operative mode specific to Nuos: GREEN / COMFORT / FAST / IMEMORY).
# `set_nuos_mode` posts to `/operativeMode`, so the server updates
# `opMode`. The `water_heater_mode_value` getter also reads `opMode`,
# so the optimistic cache update has to mirror that field, not the
# generic `mode`.
self.data[NuosSplitProperties.OP_MODE] = NuosSplitOperativeMode[

Copy link
Copy Markdown
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Please update test_nuos_split_properties_sync_async_and_missing_state_defaults with this cache-key correction. Its fixture has no MODE entry, but the sync and async assertions still read device.data[NuosSplitProperties.MODE]; this change writes OP_MODE, so the existing test raises KeyError and does not verify the getter-backed field. Assert OP_MODE/water_heater_mode_value for both paths.

operation_mode
].value

Expand All @@ -213,7 +220,10 @@ async def async_set_water_heater_operation_mode(self, operation_mode: str):
await self.api.async_set_nuos_mode(
self.gw, NuosSplitOperativeMode[operation_mode]
)
self.data[NuosSplitProperties.MODE] = NuosSplitOperativeMode[
# See note in `set_water_heater_operation_mode`: the cloud
# /operativeMode endpoint updates `opMode`, which is also what the
# `water_heater_mode_value` getter reads.
self.data[NuosSplitProperties.OP_MODE] = NuosSplitOperativeMode[
operation_mode
].value

Expand Down
20 changes: 16 additions & 4 deletions tests/test_device_models.py
Original file line number Diff line number Diff line change
Expand Up @@ -307,12 +307,16 @@ def test_nuos_split_properties_sync_async_and_missing_state_defaults(self):
self.assertNotIn(NuosSplitProperties.PROC_REQ_TEMP, device.data)
device.set_water_heater_reduced_temperature(42)
device.set_water_heater_operation_mode("FAST")
# The getter must reflect the requested mode immediately (regression:
# setter used to write `mode` while the getter reads `opMode`).
self.assertEqual(device.water_heater_mode_value, NuosSplitOperativeMode.FAST.value)
self.assertNotIn(NuosSplitProperties.MODE, device.data)
device.set_min_setpoint_temp(35)
device.set_preheating(True)
device.set_heating_rate(5)
self.assertEqual(device.data[NuosSplitProperties.COMFORT_TEMP], 43)
self.assertEqual(device.data[NuosSplitProperties.REDUCED_TEMP], 42)
self.assertEqual(device.data[NuosSplitProperties.MODE], NuosSplitOperativeMode.FAST.value)
self.assertEqual(device.data[NuosSplitProperties.OP_MODE], NuosSplitOperativeMode.FAST.value)
device.api.set_nuos_temperature.assert_called_with("gw-1", 43, 42, 60, 40)
device.api.set_velis_plant_setting.assert_called()

Expand All @@ -335,7 +339,9 @@ async def set_values():

asyncio.run(set_values())
self.assertTrue(device.data[NuosSplitProperties.BOOST_ON])
self.assertEqual(device.data[NuosSplitProperties.MODE], NuosSplitOperativeMode.GREEN.value)
self.assertEqual(device.data[NuosSplitProperties.OP_MODE], NuosSplitOperativeMode.GREEN.value)
self.assertEqual(device.water_heater_mode_value, NuosSplitOperativeMode.GREEN.value)
self.assertNotIn(NuosSplitProperties.MODE, device.data)
self.assertEqual(device.plant_settings[SlpDeviceSettings.SLP_HEATING_RATE], 4)
self.assertEqual(device.api.async_set_velis_plant_setting.await_count, 3)

Expand Down Expand Up @@ -429,7 +435,10 @@ def test_nuos_split_green_plus_mode_is_exposed_and_settable(self):

device.set_water_heater_operation_mode("GREEN_PLUS")
self.assertEqual(
device.data[NuosSplitProperties.MODE], NuosSplitOperativeMode.GREEN_PLUS.value
device.data[NuosSplitProperties.OP_MODE], NuosSplitOperativeMode.GREEN_PLUS.value
)
self.assertEqual(
device.water_heater_mode_value, NuosSplitOperativeMode.GREEN_PLUS.value
)
device.api.set_nuos_mode.assert_called_once_with(
"gw-1", NuosSplitOperativeMode.GREEN_PLUS
Expand All @@ -438,7 +447,10 @@ def test_nuos_split_green_plus_mode_is_exposed_and_settable(self):
device.api.async_set_nuos_mode = AsyncMock()
asyncio.run(device.async_set_water_heater_operation_mode("GREEN_PLUS"))
self.assertEqual(
device.data[NuosSplitProperties.MODE], NuosSplitOperativeMode.GREEN_PLUS.value
device.data[NuosSplitProperties.OP_MODE], NuosSplitOperativeMode.GREEN_PLUS.value
)
self.assertEqual(
device.water_heater_mode_value, NuosSplitOperativeMode.GREEN_PLUS.value
)
device.api.async_set_nuos_mode.assert_awaited_once_with(
"gw-1", NuosSplitOperativeMode.GREEN_PLUS
Expand Down