86 changes: 44 additions & 42 deletions .github/ISSUE_TEMPLATE/test-suite-run.md
Original file line number Diff line number Diff line change
Expand Up @@ -10,9 +10,9 @@ assignees: ""

**PlanktoScope**

- Hardware version: eg `v2.5`
- Software version: eg `2025.0.0.alpha.1`
- Machine name: eg `sponge-care-245`
- Hardware version: eg `v2.6` or `v3.0`
- Software version: eg `2026.0.0-beta.1`
- Machine name: eg `sponge-bob`
- Serial number: eg `U132` (leave empty if unknown)

**Computer**
Expand All @@ -26,52 +26,50 @@ Anything else worth knowing?

# Test suite

## Setup
(re) start the PlanktoScope

1. [Set up the SD card and start the PlanktoScope](https://docs.planktoscope.community/setup/software/standard-install/)
2. [ ] The PlanktoScope asks for Hardware version

## Sample
<!--## Sample

1. Go to "Sample"
2. Select "Plankton net" for Sample gear
3. Fill the form
4. [ ] The calculations are correct
4. [ ] The calculations are correct-->

<!-- TODO: Add a tool to verify calculations -->

## Optic

**LED and preview**

1. [ ] "Light on" turns on the LED
1. [ ] Light "On" turns on the LED
2. [ ] The preview shows images without significant lag
3. [ ] Updating "ISO" modifies the image
4. [ ] Updating "Shutter Speed" modifies the image
<!-- 5. [ ] Verify white balance-->
5. [ ] "Light off" turns off the LED
3. [ ] The "Calibrate" button performs a successful calibration
4. [ ] Light "Off" turns off the LED

**Focus**

1. [ ] "UP 1MM" moves the focus in one direction
2. [ ] "DOWN 1MM" moves the focus in the other direction
3. [ ] Quick succession of "UP 100MM" moves the focus in one direction
4. [ ] Quick succession of "DOWN 100MM" moves the focus in the other direction
5. [ ] "Focus Distance" and "Focus Speed" impacts "⩓" in one direction
6. [ ] "Focus Distance" and "Focus Speed" impacts "⩔" in the other direction
7. [ ] "STOP FOCUS" stops movement

<!-- TODO: Add focus scenarios -->
1. [ ] "500 μm" + "Near" moves the stage towards the camera
2. [ ] "500 μm" + "Far" moves the stage away from the camera
3. [ ] "Stop" stops movement

**Pump**

1. [ ] The left arrow pumps in one direction
2. [ ] The right arrow pumps in the other direction
3. [ ] "Flowrate" and "Volume to pass" impacts speed in one direction
4. [ ] "Flowrate" and "Volume to pass" impacts speed in the other direction
5. [ ] "STOP PUMP" stops the pump
1. [ ] "Backward" pumps in the direction of the camera
2. [ ] "Forward" pumps in the opposite direction of the camera
3. [ ] "Flowrate" impacts "Backward" speed
4. [ ] "Flowrate" impacts "Forward" speed
5. [ ] "Volume" impacts "Backward" duration
6. [ ] "Volume" impacts "Forward" duration
7. [ ] "Stop" stops the pump

<!-- TODO: Add pump scenarios -->
**Bubbler**

1. Connect tube, needle and plunge in a glass of water
2. [ ] `25%` generates slow bubbles
3. [ ] `50%` generates bubbles faster than `25%`
4. [ ] `75%` generates bubbles faster than `55%`
4. [ ] `100%` generates bubbles faster than `75%`
5. [ ] `Off` stops the bubbler

**Prepare**

Expand Down Expand Up @@ -129,26 +127,27 @@ Setup focus in "Optic Configuration"
5. Import the zip and wait for completion
6. [ ] The result on Ecotaxa matches expectations

## System Monitoring

1. "Metrics" are coherent
2. "Information" is correct

## Administration

1. [ ] Logs can be viewed and downloaded
2. [ ] "Restart Hardware Controller" button is working
3. [ ] "Restart Segmenter" button is working
4. [ ] "Reboot" button is working
5. [ ] "Shutdown" button is working
1. [ ] "Reboot" button is working
2. [ ] "Shutdown" button is working

## Network

Replace `{machine-name}` with your PlanktoScope name.

### Direct Ethernet

1. Connect the USB <-> RJ45 cable (USB on your computer, RJ45 on the PlanktoScope)
2. Enable connection sharing on your computer
3. [ ] The PlanktoScope displays an IP address different than `192.168.4.1` (v3 only)
4. [ ] PlanktoScope is accessible at [http://<ip-address>/](http://<ip-address>/)
5. [ ] The preview works correctly

### Direct WiFi

1. Connect your computer to the PlanktoScope WiFi hotspot
1. [ ] The WiFi network "PlanktoScope {machine-name}" is visible
2. [ ] You can connect your computer to the PlanktoScope WiFi hotspot
2. PlanktoScope is accessible at
1. [ ] [http://planktoscope.local](http://planktoscope.local)
2. [ ] [http://192.168.4.1/](http://192.168.4.1/)
Expand All @@ -157,8 +156,11 @@ Replace `{machine-name}` with your PlanktoScope name.
### LAN Ethernet

1. Connect the PlanktoScope to your router ethernet
2. PlanktoScope is accessible at
1. [ ] [http://planktoscope-{machine-name}.local](http://planktoscope-{machine-name}.local)
2. [ ] The PlanktoScope displays an IP address different than `192.168.4.1` (v3 only)
3. [ ] PlanktoScope is accessible at [http://<ip-address>/](http://<ip-address>/)
4. [ ] Preview works correctly
5. [ ] PlanktoScope is accessible at [http://planktoscope-{machine-name}.local](http://planktoscope-{machine-name}.local)
6. [ ] Preview works correctly

## Additional tests

Expand Down