Monitor and control V-Guard Wi-Fi smart inverters and water heaters from Home Assistant over your own MQTT broker, without the V-Guard cloud.

This is an independent community integration. It is not made, supported or endorsed by V-Guard Industries.

Features

  • Local push. Readings arrive over MQTT every couple of seconds; nothing is polled from the cloud.
  • Power: mains and output voltage, output frequency, load, and whether the house runs on mains or battery.
  • Battery: voltage, charging current, status, health, capacity and the estimated backup time.
  • Backup energy: a running total of energy supplied from the battery, usable in the Energy dashboard.
  • Settings: inverter mode (Normal, UPS, Equipment), turbo charging, mains changeover buzzer, appliance mode, daytime load usage, performance level and load alarm threshold.
  • Water heaters (beta, read-only): whether it's on, water and target temperature, and whether it's heating.
  • Discovery: finds devices on the broker during setup.
  • Availability: entities go unavailable when a device drops off the broker or stops reporting.

Water heater support is built from an earlier version's notes and has been checked against a simulated heater, not yet a real one. It only reads the heater; nothing is sent to it. Power and temperature control will return in a later release once they are confirmed on real hardware. Please open an issue with a debug log if your heater's readings look wrong.

Requirements

  • Home Assistant 2025.3 or newer, with the MQTT integration set up.
  • An MQTT broker on your network (for example the Mosquitto add-on), listening on port 1883.
  • A DNS server you control (AdGuard Home, Pi-hole or your router) that the inverter uses.
  • A V-Guard smart inverter or water heater already connected to your Wi-Fi with the V-Guard app.

Point the devices at your broker

V-Guard devices connect to vguardbox.com with plain MQTT: inverters on port 1883, water heaters on port 8883 (without TLS). Make your broker listen on both, for example in mosquitto.conf:

listener 1883
listener 8883
allow_anonymous true

Then redirect vguardbox.com to your broker:

  • AdGuard Home: Filters → DNS rewrites → add vguardbox.com → your broker's IP.
  • Pi-hole: Local DNS → DNS Records → add vguardbox.com → your broker's IP.
  • Router: add a static DNS entry for vguardbox.com pointing at your broker.

Then power-cycle the devices, or wait for them to reconnect. To check it worked, listen on the broker:

mosquitto_sub -h <broker-ip> -t 'device/#' -v

An inverter shows device/dups/CE01/lwt/<serial> online within a minute; its telemetry starts once Home Assistant asks for it. A water heater shows up under device/smartewh/3013/ while it's switched on.

The V-Guard app stops working remotely while the devices talk to your broker instead of the cloud.

Installation

With HACS (recommended)

  1. Open HACS in Home Assistant.
  2. Search for V-Guard Smart, open it, and click Download.
  3. Restart Home Assistant.

Not listed yet? Open HACS → ⋮ → Custom repositories, add https://github.com/dtechterminal/vguard_ups_ha as an Integration, then search again.

Manually

Download the source code of the latest release, copy its custom_components/vguard_inverter folder into your Home Assistant config/custom_components/ folder, and restart Home Assistant.

Setup

  1. Go to Settings → Devices & services → Add integration and choose V-Guard Smart.
  2. Choose Find devices on MQTT. Setup listens on the broker for a few seconds and lists the devices it heard. Switch a water heater on first; it's only on the broker while it has power.
  3. Pick your device. For a water heater, setup then asks for its encryption key (see below); leave it empty to start with.

If nothing is found, choose Enter the serial number instead. The serial number is the last part of the device's topic, device/dups/CE01/<serial> or device/smartewh/3013/<serial>.

Water heater encryption key

Some water heaters may encrypt their messages with a 16-character key and IV that V-Guard's cloud gives the app for each heater. If your heater is on the broker but its readings stay empty, add them. The V-Guard app's account API returns them with your product list (key and iv). Add them by removing the heater and setting it up again.

Entities

Inverter

Entity Type Notes
Mains voltage, Output voltage Sensor V
Output frequency Sensor Hz
Load Sensor % of the inverter's rating; 0 while on mains
Power source Sensor Mains or Battery
Battery voltage, Charging current Sensor V, A
Battery status Sensor Normal, Charging or Low
Battery health Sensor %
Backup time Sensor Estimated minutes on battery at the current load
Backup energy used Sensor Wh supplied from the battery, total increasing
Battery capacity, Low battery alarm voltage Sensor Diagnostic
Wi-Fi signal, Wi-Fi network Sensor Diagnostic, disabled by default
Inverter mode Select Normal, UPS or Equipment
Turbo charging, Mains changeover buzzer, Appliance mode, Daytime load usage Switch Inverter settings
Performance level, Load alarm threshold Number Inverter settings

Water heater (beta)

Entity Type Notes
Water heater Water heater On or off, water temperature and target temperature (read-only)
Heating Binary sensor On while the element heats
Wi-Fi signal, Wi-Fi network Sensor Diagnostic, disabled by default

The firmware version and Wi-Fi MAC address appear on the device page.

How it works

The inverter publishes a retained online/offline message on device/dups/<model>/lwt/<serial>. After it receives start on apps/dups/<model>/<serial> it streams telemetry on device/dups/<model>/<serial> for about four minutes. The integration sends start every minute so the stream never stops. Settings are changed by sending <code>:<value> (for example VG099:1) to the same topic, and the next telemetry confirms the change.

A water heater reports under smartewh while it has power: VG094 is 1 when on, VG007 starts with the water temperature, and VG041 or VG007 holds the target. With a key, encrypted (AES-128-CBC, base64) messages are decrypted. The integration sends nothing to water heaters.

Troubleshooting

  • No devices found: check that vguardbox.com resolves to your broker from the device's network, and that mosquitto_sub (above) shows the lwt topic. Water heaters only appear while switched on.

  • Entities unavailable: the device is offline on the broker or has stopped reporting. Check its power, Wi-Fi and the broker. A water heater switched off at the wall shows as unavailable.

  • Water heater readings stay empty while it's on: add its encryption key (above).

  • Debug logging: add this to configuration.yaml and restart:

    logger:
      logs:
        custom_components.vguard_inverter: debug

Upgrading from 2.x

Version 3.0 rewrites the integration. Existing entries are migrated, but most entities are new because several 2.x sensors were mapped to the wrong values (for example "Battery Percentage" was the load). Remove old entities that show as unavailable, and update dashboards and automations to the new entity IDs.

License

The code is MIT licensed. The V-Guard name and logo belong to V-Guard Industries; see docs/branding.md.