Solis Monitor

Monitoring solution for Solis inverters using Modbus TCP/RTU. Polls register data, stores it in SQLite, and exposes it via a web API, frontend dashboard and Prometheus metrics.

solism3 solism1 solism2

API

After starting, the API Docs are available at /docs.

Health Check

A health check endpoint is available at /health.

Metrics

If enabled, Prometheus metrics are exposed at /metrics.

Configuration

Copy config.yaml and adjust settings. All options can be overridden via environment variables using the SOLIS_ prefix (e.g., SOLIS_MODBUS_HOST=192.168.1.200).

Example Configuration

# Solis-Monitor Configuration
app:
  debug: INFO      # DEBUG, INFO, WARN, ERROR, FATAL
  port: 8080
  timeout: 30s

poller:
  interval: 30s
  block_attempts: 3
  block_retry_delay: 1s
  block_interval: 0s
  poll_timeout: 30s

modbus:
  type: tcp
  host: 192.168.2.151
  port: 502
  timeout: 5s
  unit_id: 1
  # For RTU:
  # type: rtu
  # serial_port: /dev/ttyUSB0
  # baud_rate: 9600
  # data_bits: 8
  # stop_bits: 1
  # parity: none

storage:
  path: ./data/solis.db
  daily_retention: 87600h  # 10 years
  monthly_retention: 87600h
  yearly_retention: 87600h
  error_retention: 720h   # 30 days
  wal_mode: true
  synchronous: NORMAL
  temp_store: MEMORY

metrics:
  enabled: true

registers:
  disabled_keys: []
  # Example: disable specific registers
  # disabled_keys:
  #   - meter_total_active_power

App Settings

Option Type Default Description
debug string INFO Log level: DEBUG, INFO, WARN, ERROR, FATAL
port int 8080 HTTP server port (1-65535)
timeout duration 30s Request timeout

Poller Settings

Option Type Default Description
interval duration 30s Base interval between poll cycles
block_attempts int 3 Retry attempts per block if read fails
block_retry_delay duration 1s Delay between retry attempts for same block
block_interval duration 0s Delay between successive block reads (0 = immediate)
poll_timeout duration 30s Maximum duration for full poll cycle before aborting

Modbus Settings

Option Type Default Description
type string tcp Connection type: tcp, rtu, or rtu_over_tcp
host string 192.168.1.100 Modbus server IP/hostname (TCP only)
port int 502 Modbus server port (1-65535)
timeout duration 5s Connection/read timeout
unit_id byte 1 Modbus unit/slave ID (1-247)
serial_port string Serial port for RTU (e.g., /dev/ttyUSB0)
baud_rate int Baud rate for RTU
data_bits int Data bits for RTU (5, 6, 7, 8)
stop_bits int Stop bits for RTU (1, 2)
parity string Parity for RTU: none, even, odd

Storage Settings (SQLite)

Option Type Default Description
path string ./data/solis.db Path to SQLite database file
daily_retention duration 8760h Retention for daily energy values
monthly_retention duration 8760h Retention for monthly energy values
yearly_retention duration 8760h Retention for yearly energy values
error_retention duration 720h Retention for error/fault data (30 days)
wal_mode bool true Enable Write-Ahead Logging
synchronous string NORMAL Sync mode: OFF, NORMAL, FULL, EXTRA
temp_store string MEMORY Temp storage: DEFAULT, FILE, MEMORY

Metrics Settings

Option Type Default Description
enabled bool false Enable Prometheus metrics endpoint

Registers Settings

Option Type Default Description
disabled_keys []string [] Register keys to disable (exclude from polling, storage, API)

Available Registers

All registers are polled by default. Disable specific ones via registers.disabled_keys in config.

Information Registers

Key Name Address Type Scale Unit Stability
solis_model_no Solis Model No 33000 Uint16 1.0 stable
solis_dsp_version Solis DSP Version 33001 Uint16 1.0 stable
solis_hmi_version Solis HMI Version 33002 Uint16 1.0 stable
solis_protocol_version Solis Protocol Version 33003 Uint16 1.0 stable
solis_serial_number Solis Serial Number 33004 String 1.0 stable

Energy Registers

Key Name Address Type Scale Unit Stability
pv_today_energy Solis PV Today Energy Generation 33035 Uint16 0.1 kWh dynamic
pv_month_energy Solis PV Current Month Energy Generation 33031 Uint32 1 kWh dynamic
pv_year_energy Solis PV This Year Energy Generation 33037 Uint32 1 kWh dynamic
pv_total_energy Solis PV Total Energy Generation 33029 Uint32 1 kWh dynamic

PV Voltage/Current Registers

Key Name Address Type Scale Unit Stability
pv_voltage_1 Solis PV Voltage 1 33049 Uint16 0.1 V dynamic
pv_current_1 Solis PV Current 1 33050 Uint16 0.1 A dynamic
pv_voltage_2 Solis PV Voltage 2 33051 Uint16 0.1 V dynamic
pv_current_2 Solis PV Current 2 33052 Uint16 0.1 A dynamic
pv_voltage_3 Solis PV Voltage 3 33053 Uint16 0.1 V dynamic
pv_current_3 Solis PV Current 3 33054 Uint16 0.1 A dynamic
pv_voltage_4 Solis PV Voltage 4 33055 Uint16 0.1 V dynamic
pv_current_4 Solis PV Current 4 33056 Uint16 0.1 A dynamic

PV Power and Bus Registers

Key Name Address Type Scale Unit Stability
total_pv_power Solis Total PV Power 33057 Uint32 1 W dynamic

Grid Voltage/Current Registers

Key Name Address Type Scale Unit Stability
a_phase_voltage Solis A Phase Voltage 33073 Uint16 0.1 V dynamic
b_phase_voltage Solis B Phase Voltage 33074 Uint16 0.1 V dynamic
c_phase_voltage Solis C Phase Voltage 33075 Uint16 0.1 V dynamic
a_phase_current Solis A Phase Current 33076 Uint16 0.1 A dynamic
b_phase_current Solis B Phase Current 33077 Uint16 0.1 A dynamic
c_phase_current Solis C Phase Current 33078 Uint16 0.1 A dynamic
active_power Solis Active Power 33079 Uint32 1 W dynamic
reactive_power Solis Reactive Power 33081 Int32 0.1 VAR dynamic
apparent_power Solis Apparent Power 33083 Uint32 0.1 VA dynamic
grid_frequency Solis Grid Frequency 33094 Uint16 0.01 HZ dynamic

Temperature and Status Registers

Key Name Address Type Scale Unit Stability
temperature Solis Temperature 33093 Int16 0.1 C dynamic
solis_status Solis Status 33095 Uint16 1.0 dynamic

Fault Registers

Key Name Address Type Scale Unit Stability
grid_fault_status_01 Solis Grid Fault Status 01 (Bitmask) 33116 Uint16 1.0 dynamic
backup_load_fault_status_02 Solis Backup Load Fault Status 02 (Bitmask) 33117 Uint16 1.0 dynamic
battery_fault_status_03 Solis Battery Fault Status 03 (Bitmask) 33118 Uint16 1.0 dynamic
device_fault_status_04 Solis Device Fault Status 04 (Bitmask) 33119 Uint16 1.0 dynamic
device_fault_status_05 Solis Device Fault Status 05 (Bitmask) 33120 Uint16 1.0 dynamic
operating_status Solis Operating Status (Bitmask) 33121 Uint16 1.0 dynamic

Battery Registers

Key Name Address Type Scale Unit Stability
battery_voltage Solis Battery Voltage 33133 Uint16 0.1 V dynamic
battery_current Solis Battery Current 33134 Int16 0.1 A dynamic
battery_current_direction Solis Battery Current Direction 33135 Uint16 1.0 dynamic
battery_soc Solis Battery SOC 33139 Uint16 1.0 % dynamic
battery_soh Solis Battery SOH 33140 Uint16 1.0 % dynamic
battery_voltage_bms Solis Battery Voltage (BMS) 33141 Uint16 0.01 V dynamic
battery_fault_status_1_bms Solis Battery Fault Status 1 (BMS) 33145 Uint16 1.0 dynamic
battery_fault_status_2_bms Solis Battery Fault Status 2 (BMS) 33146 Uint16 1.0 dynamic
battery_power Solis Battery Power 33149 Int32 1 W dynamic

Backup Registers

Key Name Address Type Scale Unit Stability
backup_ac_voltage_phase_a Solis Backup AC Voltage Phase A 33137 Uint16 0.1 V dynamic
backup_ac_current_phase_a Solis Backup AC Current Phase A 33138 Uint16 0.1 A dynamic
household_load_power Solis Household Load Power 33147 Uint16 1 W dynamic
backup_load_power Solis Backup Load Power 33148 Uint16 1 W dynamic
ac_grid_port_power Solis AC Grid Port Power 33151 Int32 0.1 W dynamic

Battery Energy Registers

Key Name Address Type Scale Unit Stability
today_battery_charge_energy Solis Today Battery Charge Energy 33163 Uint16 0.1 kWh dynamic
today_battery_discharge_energy Solis Today Battery Discharge Energy 33167 Uint16 0.1 kWh dynamic
total_battery_discharge_energy Solis Total Battery Discharge Energy 33165 Uint32 1 kWh dynamic
total_battery_charge_energy Solis Total Battery Charge Energy 33161 Uint32 1 kWh dynamic

Grid Energy Registers

Key Name Address Type Scale Unit Stability
today_energy_imported_from_grid Solis Today Energy Imported From Grid 33171 Uint16 0.1 kWh dynamic
total_energy_imported_from_grid Solis Total Energy Imported From Grid 33169 Uint32 0.1 kWh dynamic
total_energy_fed_into_grid Solis Total Energy Fed Into Grid 33173 Uint32 0.1 kWh dynamic
today_energy_fed_into_grid Solis Today Energy Fed Into Grid 33175 Uint16 0.1 kWh dynamic
today_energy_consumption Solis Today Energy Consumption 33179 Uint16 0.1 kWh dynamic
total_energy_consumption Solis Total Energy Consumption 33177 Uint32 1 kWh dynamic

Household Load Registers

Key Name Address Type Scale Unit Stability
household_load_today_energy Solis Household Load Today Energy 33586 Uint16 0.1 kWh dynamic
household_load_year_energy Solis Household Load Year Energy 33582 Uint32 1 kWh dynamic
household_load_month_energy Solis Household Load Month Energy 33584 Uint32 1 kWh dynamic
household_load_total_energy Solis Household Load Total Energy 33580 Uint32 1 kWh dynamic

Backup Load Registers

Key Name Address Type Scale Unit Stability
backup_load_today_energy Solis Backup Load Today Energy 33596 Uint16 0.1 kWh dynamic
backup_load_total_energy Solis Backup Load Total Energy 33590 Uint32 1 kWh dynamic
backup_load_year_energy Solis Backup Load Year Energy 33592 Uint32 1 kWh dynamic
backup_load_month_energy Solis Backup Load Month Energy 33594 Uint32 1 kWh dynamic

Meter Registers

Key Name Address Type Scale Unit Stability
meter_ac_voltage_a Solis Meter AC Voltage A 33251 Uint16 0.1 V dynamic
meter_ac_current_a Solis Meter AC Current A 33252 Uint16 0.1 A dynamic
meter_ac_voltage_b Solis Meter AC Voltage B 33253 Uint16 0.1 V dynamic
meter_ac_current_b Solis Meter AC Current B 33254 Uint16 0.1 A dynamic
meter_ac_voltage_c Solis Meter AC Voltage C 33255 Uint16 0.1 V dynamic
meter_ac_current_c Solis Meter AC Current C 33256 Uint16 0.1 A dynamic
meter_active_power_a Solis Meter Active Power A 33257 Int32 0.1 W dynamic
meter_active_power_b Solis Meter Active Power B 33259 Int32 0.1 W dynamic
meter_active_power_c Solis Meter Active Power C 33261 Int32 0.1 W dynamic
meter_total_active_power Solis Meter Total Active Power 33263 Int32 1.0 W dynamic

Running

Docker (recommended)

# Production
docker-compose up -d

# Development (builds from source)
docker-compose -f docker-compose.dev.yaml up --build

Both mount ./data for persistence and ./config.yaml for configuration.

---
services:
  app:
    image: ghcr.io/dombyte/solis:latest
    volumes:
      - ./data:/app/data
      - ./config.yaml:/app/config.yaml:ro
    ports:
      - "8080:8080"
    restart: unless-stopped
    environment:
      - TZ=Europe/Berlin
    healthcheck:
      test: ["CMD", "httpcheck", "http://localhost:8080/health"]
      interval: 30s
      timeout: 10s
      retries: 3

Local

go run ./cmd
# or build first
go build -o solis ./cmd && ./solis

Development

# Build
go build -o solis ./cmd

# Run tests
go test ./...

# Format code
go fmt ./...

# Update dependencies
go mod tidy

Frontend

cd frontend
npm install
npm run dev