Notifications
You must be signed in to change notification settings - Fork 1
Camadas de infraestrutura de DataCenter #7 #57
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Open
gabrielbdb
wants to merge
15
commits into
main
Choose a base branch
from
gabrielbdb/issue7
base: main
Could not load branches
Branch not found: {{ refName }}
Loading
Could not load tags
Nothing to show
Loading
Are you sure you want to change the base?
Some commits from the old base branch may be removed from the timeline,
and old review comments may become outdated.
Open
Changes from all commits
Commits
Show all changes
15 commits
Select commit
Hold shift + click to select a range
e21ed1d
Criei o arquivo
gabrielbdb 4444bce
Arquivo movido pra pasta content.
gabrielbdb 40f9416
Criação de arquivo slides
gabrielbdb 6b223d0
Primeiro slide
gabrielbdb 4cda559
Elaboração do segundo slide com comentário (Breve resumo de datacenter)
gabrielbdb 1ba43cb
Novo slide e definição da camada 1
gabrielbdb 816ccae
Atualização dos slides e definição das camadas
gabrielbdb e4dd12e
Agradecimento final
gabrielbdb 1be8ea5
Atualizei o arquivo md sem os slides
gabrielbdb aef3b55
Adiçao de comentários
gabrielbdb 66cf722
Adição de novos comentários
gabrielbdb c8665ed
Atualizando imagem
gabrielbdb 160ff23
Incluindo os comentários no arquivo sem slides
gabrielbdb 3880b91
Correções para separação de slides e comentários
gabrielbdb 51c984d
atualização da dimensão das imagens
gabrielbdb File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,42 @@ | ||
| # Camadas de infraestrutura de DataCenter #7 | ||
|
|
||
| ###### Gabriel Braga 👋 | ||
|
|
||
| # Breve resumo sobre o que significa DataCenter | ||
|
|
||
|  | ||
|
|
||
| #### O que é e pra que serve? | ||
|
|
||
| Bom, antes de avançarmos para as camadas do Datacenter é importante resumir o que é DataCenter e pra que serve. | ||
| Datacenter é um ambiente de armazenamento, processamento e gerenciamento de grande volume de dados e informações projetado para fornecer alguns recursos necessários para garantir alguns serviços essenciais. Ex: CRM | ||
| ---> | ||
|
|
||
| # A implementação de um DataCenter segue a norma ANSI/TIA-942 (Classificada em 4 camadas) | ||
| # Definição das 4 camadas: | ||
|
|
||
| <!---Um dos padrões mais adotados para o | ||
| design e a infraestrutura é o ANSI/TIA-942. Ele inclui os padrões da certificação, que garante a conformidade com uma das quatro categorias de camadas de data center classificadas para níveis de redundância e tolerância a falhas | ||
| ---> | ||
|
|
||
| # Camada 1 | ||
| - É o nível mais básico, com uma infraestrutura mínima. Um data center de camada 1 oferece proteção limitada contra eventos físicos. Possui componentes de capacidade única e um caminho de distribuição único e não redundante. | ||
| Sobre a camada 1, possui uma infraestrutura básica do local. Um data center de camada 1 oferece proteção limitada contra eventos físicos. | ||
|
|
||
| # Camada 2 | ||
|
|
||
| - Este nível inclui algum grau de redundância para componentes críticos, como fontes de energia e sistemas de resfriamento. Também pode oferecer maior proteção contra interrupções não planejadas. | ||
| A camada 2 infraestrutura do local dos componentes com capacidade redundante. Esse data center, diferente da camada 1, oferece proteção melhorada contra eventos físicos.---> | ||
|
|
||
| # Camada 3 | ||
|
|
||
| - É um nível intermediário que fornece redundância em todos os principais sistemas, permitindo manutenção planejada sem afetar a disponibilidade dos serviços. Possui múltiplos caminhos de distribuição de energia e sistemas de resfriamento com capacidade de manutenção simultânea. | ||
| - Sobre a camada 3, esse data center protege contra praticamente todos os eventos físicos, fornecendo componentes com capacidade redundante e vários caminhos de distribuição independentes. Cada componente pode ser removido ou substituído sem interromper os serviços para os usuários finais. | ||
|
|
||
| # Camada 4 | ||
|
|
||
| - É o nível mais alto de classificação e oferece o mais alto grau de disponibilidade e redundância. Possui sistemas completamente redundantes, com capacidade de manutenção contínua sem afetar os serviços. Também possui proteção contra falhas em todos os componentes críticos. | ||
|
|
||
| - A camada 4 fornece os mais altos níveis de tolerância a falhas e redundância componentes de capacidade redundante e vários caminhos de distribuição independentes permitem a manutenção simultânea e uma falha em qualquer lugar da instalação, sem causar período de inatividade. | ||
|
|
||
| # Obrigado 👋 | ||
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,58 @@ | ||
| --- | ||
| marp: true | ||
| theme: uncover | ||
| --- | ||
|
|
||
| # Camadas de infraestrutura de DataCenter #7 | ||
|
|
||
| ###### Gabriel Braga 👋 | ||
|
|
||
| --- | ||
|
|
||
| # Breve resumo sobre o que significa DataCenter | ||
|
|
||
| <p align="middle"> | ||
| <img src="https://encrypted-tbn0.gstatic.com/images?q=tbn:ANd9GcQQQKcQ_pWaDi36doW5a2i3PSK9UNLhIIfoXA&usqp=CAU" width="5500px"> | ||
| </p> | ||
|
|
||
| #### O que é e pra que serve? | ||
|
|
||
| <!---Bom, antes de avançarmos para as camadas do Datacenter é importante resumir o que é DataCenter e pra que serve. Datacenter é um ambiente de armazenamento, processamento e gerenciamento de grande volume de dados e informações projetado para fornecer alguns recursos necessários para garantir alguns serviços essenciais. Ex: CRM | ||
| ---> | ||
|
|
||
| --- | ||
| # A implementação de um DataCenter segue a norma ANSI/TIA-942 (Classificada em 4 camadas) | ||
| # Definição das 4 camadas: | ||
|
|
||
| <!---Um dos padrões mais adotados para o design e a infraestrutura é o ANSI/TIA-942. Ele inclui os padrões da certificação, que garante a conformidade com uma das quatro categorias de camadas de data center classificadas para níveis de redundância e tolerância a falhas | ||
| ---> | ||
| --- | ||
|
|
||
| # Camada 1 | ||
| - É o nível mais básico, com uma infraestrutura mínima. Um data center de camada 1 oferece proteção limitada contra eventos físicos. Possui componentes de capacidade única e um caminho de distribuição único e não redundante. | ||
| <!---Sobre a camada 1, possui uma infraestrutura básica do local. Um data center de camada 1 oferece | ||
| proteção limitada contra eventos físicos.---> | ||
| --- | ||
|
|
||
| # Camada 2 | ||
|
|
||
| - Este nível inclui algum grau de redundância para componentes críticos, como fontes de energia e sistemas de resfriamento. Também pode oferecer maior proteção contra interrupções não planejadas. | ||
|
|
||
|
|
||
| <!---A camada 2 infraestrutura do local dos componentes com capacidade redundante. Esse data center, diferente da camada 1, oferece proteção melhorada contra eventos físicos.---> | ||
|
|
||
| --- | ||
|
|
||
| # Camada 3 | ||
| - É um nível intermediário que fornece redundância em todos os principais sistemas, permitindo manutenção planejada sem afetar a disponibilidade dos serviços. Possui múltiplos caminhos de distribuição de energia e sistemas de resfriamento com capacidade de manutenção simultânea. | ||
| <!---Sobre a camada 3, esse data center protege contra praticamente todos os eventos físicos, fornecendo componentes com capacidade redundante e vários caminhos de distribuição independentes. Cada componente pode ser removido ou substituído sem interromper os serviços para os usuários finais.---> | ||
| --- | ||
| # Camada 4 | ||
|
|
||
| - É o nível mais alto de classificação e oferece o mais alto grau de disponibilidade e redundância. Possui sistemas completamente redundantes, com capacidade de manutenção contínua sem afetar os serviços. Também possui proteção contra falhas em todos os componentes críticos. | ||
|
|
||
| <!---A camada 4 fornece os mais altos níveis de tolerância a falhas e redundância componentes de capacidade redundante e vários caminhos de distribuição independentes permitem a manutenção simultânea e uma falha em qualquer lugar da instalação, sem causar período de inatividade.---> | ||
|
|
||
| --- | ||
|
|
||
| # Obrigado 👋 |
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Uh oh!
There was an error while loading. Please reload this page.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Oi Gabriel, boa tarde!
Passando aqui pra lembrá-lo de trocar o nome da sua sua pull request para o título da sua apresentação.
Pra fazer isso, em frente ao título (Criando o arquivo #7), do lado esquerdo da tela, tem um botão chamado Edit. Clica nele.
Daí vc vai poder trocar para, por exemplo: Introdução ao DataCenter
Um forte abraço!
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Muito obrigado, @jmtannus . Realmente não havia me lembrado de alterar o título. Agradeço e desculpa a demora pela resposta!