A neuro-physiological cognitive-state guardian for aviation safety.
Most loss-of-control aviation accidents trace back to a loss of airplane-state awareness — a pilot who is distracted, fixated, or startled at the wrong moment. VIGIL is a defensive ML pipeline that estimates a pilot's cognitive state from multimodal biosignals (EEG, ECG, respiration, electrodermal activity) so that dangerous states can be flagged in real time, before they become accidents.
It sits at the intersection of aerospace · neuroscience · medicine, and it is deliberately defensive: the output is a cockpit alert that protects the operator, not a weapon system.
Status: working end-to-end on real human EEG (36 subjects, PhysioNet EEGMAT) and on a physiologically grounded simulator, with drop-in adapters for aviation-specific datasets. Honest leave-one-subject-out evaluation throughout. Tests passing.
VIGIL classifies four states (the dangerous three are drawn directly from NASA's aviation-safety taxonomy):
| State | Why it kills | Signature VIGIL looks for |
|---|---|---|
| Baseline | — (calm, nominal) | balanced spectra, stable HR |
| Channelized attention | target fixation → flying a working aircraft into terrain | frontal-midline theta ↑, posterior alpha ↓ |
| Diverted attention | task-switching, missed instruments | fluctuating beta ↑, irregular respiration |
| Startle / surprise | freeze / overcorrection after a jolt | broadband EEG transient, HRV collapse, EDA arousal |
The central methodological point of this project: in biosignal classification, how you split the data decides whether your number means anything.
If epochs from the same person land in both train and test (a random/stratified k-fold over epochs), the model memorizes each subject's physiological "fingerprint" and the score is wildly optimistic. The only deployment-relevant number is leave-one-subject-out (LOSO) — train on some pilots, test on a pilot the model has never seen.
VIGIL computes both and reports the gap, so the leakage is visible instead of hidden:
chance balanced-acc : 0.250
LOSO balanced-acc (HONEST): 0.958 <- the number that counts
within-subject (LEAKY) : 1.000 <- what you'd wrongly report
>> leakage inflation : +0.042 balanced-acc if you split wrong
safety-critical recall (LOSO) — fraction of dangerous episodes caught:
channelized_attention 1.000
diverted_attention 0.979
startle_surprise 0.875
(Numbers above are on the synthetic simulator — see "Honesty" below.)
The same pipeline and the same honest split, run on PhysioNet EEGMAT — 36 real
subjects, 19-channel 10-20 EEG, rest vs. a mental-arithmetic cognitive-load task
(./run.sh eegmat):
subjects : 36 (balanced 540 / 540 epochs)
chance balanced-acc : 0.500
LOSO balanced-acc (HONEST): 0.625 AUROC 0.678 <- subject-independent
within-subject (LEAKY) : 0.817
>> leakage inflation : +0.192 balanced-acc if you split wrong
This is the part that matters. On real brains the honest cross-subject ceiling is modest (0.625) — and a naive within-subject split would have you report 0.817. That +0.19 gap is the whole thesis, and it is ~5× larger on real data than on the clean simulator (+0.04). A model that looks great in a paper and fails on the next pilot is the failure mode VIGIL is built to expose. The numbers are deliberately un-inflated: subject-independent EEG decoding is genuinely hard, and pretending otherwise is how unsafe systems ship.
raw biosignals neurophysiological features model decision
────────────── ────────────────────────── ───── ────────
EEG (8 ch, 256 Hz) ─┐ EEG band powers (δ θ α β γ), HistGradient- per-epoch state
ECG ───────────────┤ theta/alpha & beta/alpha ratios, Boosting on ──► + debounced
RESP ───────────────┼─► frontal-theta / posterior-alpha, 69 features real-time alert
EDA ───────────────┘ HRV (SDNN/RMSSD/pNN50), resp rate (vigil.stream)
& irregularity, EDA SCL/SCR
- Handcrafted, auditable features rather than raw-signal black boxes. With only
a handful of subjects, physiologically meaningful features generalize across
people far better — and when the output is a safety alert, you want to know why
it fired. (A compact 1-D CNN baseline is included in
vigil/models.pyfor comparison.) - Permutation importance exposes which signals drive each call.
- Streaming guardian with temporal debouncing — a single noisy frame never trips the alarm; a sustained dangerous episode does.
git clone https://github.com/azrabano23/vigil
cd vigil
./run.sh demo # simulate → features → honest LOSO vs leaky eval → plots
./run.sh eegmat # REAL DATA: download PhysioNet EEGMAT (36 subj) + honest eval
./run.sh stream # live-monitor a held-out pilot, with alerts
./run.sh test # deterministic end-to-end tests
./run.sh train # feature-importance rankingNo GPU required. run.sh uses your current Python if the deps are importable,
otherwise it builds a .venv and installs requirements.txt.
VIGIL is dataset-agnostic. Internally everything is a list of epochs plus a label
array and a subject-id array. Full provenance in DATA.md.
- PhysioNet EEGMAT (real, auto-downloaded by
./run.sh eegmat) — 36 real subjects, 19-ch 10-20 EEG, rest vs. mental-arithmetic cognitive load. ODC Public Domain Dedication (fully open, no auth). The real-data backbone. Loader:vigil.realdata.load_eegmat. (Zyma et al., Data 2019.) - Synthetic simulator (default, no download) — multimodal biosignals built from the mechanisms each signal reflects, with state modulations from the aviation-neuroergonomics literature. Exercises the full multimodal pipeline and demonstrates the methodology — not a clinical claim.
- NASA — "Reducing Commercial Aviation Fatalities" (Kaggle, 2019) — 18 pilots,
22-ch EEG + ECG + respiration + GSR at 256 Hz, labeled with the dangerous
states. Released by NASA with Booz Allen Hamilton. Used under Kaggle's
competition terms; this repo does not redistribute it. Adapter:
vigil.data.load_nasa_rcaf(needs a Kaggle account). - UAB — Flight-Deck Mental-Workload EEG — CC-BY 4.0, Universitat Autònoma
de Barcelona, published in Sensors. Adapter:
vigil.data.load_uab.
- Two regimes, clearly separated. The simulator numbers (LOSO 0.958) show the pipeline and methodology are sound on clean signal. The real-data numbers (EEGMAT, LOSO 0.625 / AUROC 0.678) are the honest, un-inflated truth about subject-independent EEG decoding — and they are reported next to the leaky 0.817 so the inflation is impossible to miss. The simulator is physiologically grounded but is not real pilots; treat its metrics as a sanity check, not an operational claim.
- The leakage gap is the contribution, not the peak accuracy. A model that scores 1.000 within-subject and collapses across subjects is worthless in a cockpit; VIGIL is built to surface exactly that failure.
- Not a medical device. Research / educational artifact.
vigil/
simulate.py physiologically grounded multimodal biosignal simulator
features.py EEG band power, HRV, respiration, EDA feature extraction
data.py loaders + adapters (synthetic, NASA RCAF, UAB CC-BY)
realdata.py PhysioNet EEGMAT real-data loader + honest binary eval
models.py HistGradientBoosting (primary) + optional 1-D CNN
evaluate.py LOSO vs leaky CV, safety-critical recall, confusion plot
stream.py real-time debounced alerting on a held-out pilot
cli.py `python -m vigil {demo,eegmat,stream,train}`
tests/ deterministic end-to-end tests
DATA.md data provenance + licensing
Code: MIT. Datasets retain their own licenses (see DATA.md).