W-IND-105 — reader-inclusive NFC energy gate (2026-11-02)

  • Published on this PR branch: W-IND-105 source, tests, decision matrix, BOM and upstream audit; initial milestone commit 0d916274; branch head at verification 511dde29.
  • Decision-changing result: do not add an ST25R3916B reader solely to power one hypothetical 0.248 mW sensor. Across all 22 ST AN4913 Rev.2 tag points, the assumed 65%-efficient tag rail remains below the reader IC's chip-only active reference (14 mA typical / 23 mA max at 2.4 V, with RFO output segments disabled). Even the best tag point (12.593 mW at V_EH) gives 8.185 mW assumed sensor rail; the reader chip reference alone is 33.6 mW typical before RF output, antenna, host MCU, regulator or board losses. NFC EH remains only opportunistic while an RF field is already required for ID/data, pending measured incremental reader input.
  • Verification: WPT CI PASS, 568 tests. The independent W-IND-18 KiCad ERC still fails with three electrical violations; no schematic is approved for energization.
  • Architecture: keep dock charging separate (serviceable contact dock remains baseline); use a keyed replaceable connector for active modules until regulated WPT demonstrates net benefit; WISP5 remains only a passive-microsensor option; ESP-NOW is the one-hop candidate and OpenThread is the mesh alternative. Neither radio controls a safety stop or power cut.
  • Limits: datasheet-based analytical screen, not a physical measurement or whole-system efficiency result. No RF bench test, no purchase, no printing/soldering, no battery/BMS connection, no dock/firmware/OOMWOO/PR #79 changes, and no external code/CAD copied.
  • Local sourcing: Diotronic Zaragoza remains auxiliary; exact local stock and quote are unverified. BOM lists alternatives and prices/availability status; no purchase made.

Full detail: README_W_IND_105.md.


W-IND-103 — strict finite-data gate for ST25DV manufacturer points (2026-11-01)

  • Code: 4ebd7d4; CI invocation fix; verified evidence record.
  • Defect: the prior positivity/tolerance comparisons accepted (P_{EH}=NaN) and the pair (V_{EH}=+infty, P_{EH}=+infty); Python could then emit non-standard JSON NaN.
  • Fix: exact numeric types (bool excluded), finite positive values, exact integer AM, finite (V\times I), and the existing power tolerance are checked before calculations.
  • Tests: 11 new regression methods; 527/527 total tests pass in push CI and PR CI. Artifacts: push evidence JSON and PR evidence JSON.
  • Limit: software/data-integrity validation only. No physical WPT/RF measurements, no EM simulation, no battery/BMS/dock connection, and hardware_approved=false.
  • BOM audit (2026-11-01): Diotronic Zaragoza has no exact public listing for the tag IC, X-NUCLEO board or buffer; local counter stock/MOQ/VAT price remain unverified. DigiKey Spain: ST25DV64KC-IE8T3 €1.6577 incl. VAT, 2,838 shown, MOQ 1; X-NUCLEO-NFC07A1 €18.0048 incl. VAT, 41 shown, MOQ 1. Mouser shows the IC at €1.57 ex / about €1.8997 incl. VAT with 1,267 shown; TME exact IE8T3 not found. The 47 µF Panasonic candidate is €0.4719 incl. VAT at DigiKey but flagged not recommended for new designs; rejected pending ESR/leakage/derating. No purchase. Final documentation/BOM commit: c92af5e.
  • Separate blocker: W-IND-18 ERC still reports three electrical violations; no build or energization approval.

Latest: W-IND-102 — ST25DV64KC energy-harvesting feasibility gate (1 Nov 2026)

Published on this W-only PR: analysis/code commit 33d9126 · evidence/CI record commit be2dbbb · W-IND-102 package: 22 manufacturer points, model, 15 tests, matrix, BOM and evidence.

Material correction to W-IND-90: ST AN4913 Rev. 2 Table 1 explicitly lists ST25DV64KC, so its Tables 4–5 are applicable to that silicon family. The remaining mismatch is the antenna/setup: AN4913 uses an ISO/IEC Class 1 antenna at 13.6 MHz with 10 nF on V_EH; this does not qualify the 54 mm X-NUCLEO-NFC07A1 antenna. Maximum EH reference output is 12.593 mW (AM10, 5.5 A/m RMS) / 8.640 mW (AM100). Against the inherited, unmeasured 400 mW average / 1.5 W peak module target, the best point is only 3.148% / 0.840% (31.76× / 119.11× short): NFC EH is NO-GO for the active module.

A first non-critical microsensor is provisionally bounded at <=0.25 mW average, <=5 mW for <=10 ms with local buffering, and >=1 A/m RMS at the actual tag antenna. The 36.28 uF nominal buffer lower bound (47 uF candidate) is an energy-only calculation; ESR, leakage, cold-start, recharge and board field are unmeasured. This is conditional design guidance, not hardware qualification.

CI on final head be2dbbb: general WPT CI PASS · PR CI PASS · deterministic JSON artifact. Fifteen new deterministic tests are included. Independent W18 native ERC remains FAIL at run 41335333230: the historical unqualified W-IND-15 schematic still has three blocking findings. It was not bypassed or re-labelled as hardware approval; W-IND-21's separate declared bench-source check remains its own result.

Architecture: keep dock charging separate and battery/BMS disconnected; reject NFC EH for 400 mW modules; retain a locking serviceable connector unless a dedicated regulated WPT receiver passes FOD, thermal, offset, EMI and independent local-cut verification. ESP-NOW is the first data candidate for one-hop Espressif nodes; OpenThread only if IPv6 mesh/multi-hop is needed. Both need application ACK, CRC, sequence, timeout, bounded retry, authenticated privacy and local recovery. No radio critical stop; no WPT motors/pumps.

External ownership audit (1 Nov): Simple Wireless Power master and WISP5 hardware master match their registered SHAs; WISP5 firmware 640kHz is +68/-11 divergent; ESP-NOW master matches; OpenThread main is +21 commits with PRs #13800/#13821 merged 31 Oct. No third-party code/CAD copied or upstream repos edited. OOMWOO main f01a1b29; cleaning-jobs PR #79 remains open and untouched. Diotronic remains auxiliary; exact local stock/price/MOQ not verified. No purchases, physical tests, battery, dock, motor or station energization.


Latest: W-IND-101 — fail-closed analog thermal-window inputs (1 Nov 2026)

Published own W code: fix commit 126583ce · CI coverage fix da8660e · source/tests/matrix/BOM/evidence.

Real model defect: window_clear('0.5') or an unbounded high=+inf was accepted as a trusted analog ratio/window, allowing the abstract two-cut WPT TX interlock to return ON with malformed sensor input. W101 now requires exact built-in numeric types, finite ratio/thresholds and 0 <= low < high <= 1; malformed input forces OFF and latches after an armed-model fault. No change in real electronics; no firmware/GPIO; not a proof of physical shutdown. Local baseline 56 tests: 16 failures + 1 error; fixed 56/56 PASS (13 new + 43 existing). Fixed explicit CI test listing (first run falsely reported 488 PASS without discovering W101 tests): on exact head da8660e32d9322baa2b8ac6abd65ab3b74109074, push CI #41328506804 and PR CI #41328511940 PASS 501/501 (log inspected).

Unresolved hardware blocker: W18 native ERC #41328422422 FAIL: three pre-existing electrical violations (1 dangling VIN label, 2 undriven power pins). Neither power cutoff nor FOD, thermometry, coil offset, EMI, battery charging or RF identity are physically qualified. No purchase/energy, no OEM transplant, no OOMWOO/#79 changes. BOM incremental EUR0; Diotronic Zaragoza IVA/MOQ/stock unverified. Next gate: correct electrical ERC without fake approvals, then safety-reviewed isolated dummy-load WPT measurements only with separate authorization.


Latest: W-IND-98 — monotonic public telemetry freshness clock (1 Nov 2026)

Published: commit bf254b1 · original source, 9 new regression tests, matrix, BOM and reproducible evidence · general Python GitHub CI (push).

Material defect: ModuleReceiver.fresh could return True for stale timestamp 20ms after a valid freshness query at 200ms while the last trusted data was at 10ms. Unlike receive and tick, public fresh did not observe the monotonic clock. This could present replayed telemetry as current (non-safety telemetry only). Fix: fresh now uses the clock check for exact-integer timestamps, rejecting reverse time and latching fault; no change to 22-byte frame, CRC16, authenticated APP ACK contract, retries/expiry or local-recommissioning policy. Noninteger queries retain nonmutating False per W95. Recovery requires a strictly higher local session; durable NVM and real cryptographic RF identity remain external obligations.

Verified on exact SHA bf254b1: general CI #41315456006 PASS 470/470 (9 new + 461 regression; job log inspected). W60 ACK #41315456986 PASS and W61 authenticated link #41315456089 PASS. Independent W18 native ERC #41315456166 FAIL with 3 known violations (1 dangling label, 2 undriven power pins): DO NOT BUILD. 9 deterministic new adversarial tests in test_w_link.TestFreshnessMonotonicW98, automatically run by the existing wpt-sensor-v01-python general CI. Specific cases: direct backdated read, tick->fresh rollback, receive->fresh rollback, pre-data clock probe, successful higher epoch recovery, equal-time duplicate ACK, malformed query, negative timestamp, stale-then-rewind. No RF, WPT power, hardware cutoff, battery, BMS, dock, manufacturing or physical tests; W18 native KiCad ERC still has 3 previously known blocking violations, unrelated to the software patch. Hardware BOM delta €0; Diotronic remains auxiliary with IVA/MOQ/Zaragoza stock unverified. Source audit pins: 3 external branches identical; WISP FW 640kHz diverged (+68/-11), OpenThread main advanced +21; no borrowed code.

Next gate: isolated, independently reviewed and explicitly authorized dummy-load WPT+RF measurement; no lithium, motors or station. Own W PR only; OOMWOO and cleaning-jobs PR #79 untouched.


Latest: W-IND-97 — block stale local session/clock recommission (1 Nov 2026)

Published: commit d1084fa2 · W97 original code, regression tests, specification, BOM, decision matrix, provenance/evidence. Same scope as our existing own W PR #9. No Xiaomi/OEM, OOMWOO, #79 or external authors' sources touched.

Actual defect and correction: ModuleReceiver.commission_local accepted an equal/older session and backwards timestamp on the existing receiver object. This reset its sequence and fault latch, allowing previous telemetry to appear fresh again. Before modifying receiver state, W97 now rejects non-increasing local epochs and clock rollback with ValueError. Legitimate higher-epoch local recovery remains. The 22-byte packet format, CRC, APP ACK, retry and expiry timings stay unchanged. Across true process/MCU reboot, durable monotonic provisioning is still mandatory: the in-memory check is NOT persistent identity/authentication or hardware safety.

Measured digital evidence (own isolated PC): 8/10 adversarial cases failed on old code; after correction 10 new + 77 existing targeted tests 87/87 PASS (python3 -B -m unittest -v test_w_link test_power_restart_gate). Baseline and patched SHA256 plus reproduction in EVIDENCIA.json. GitHub CI: general suite #41309611488, ACK W60 #41309611408, authentication W61 #41309611482: all three PASS on this SHA; general CI confirms 461/461 tests (push #41309611488 and PR #41309617365, logs inspected). Independent W18 ERC #41309611430 FAIL, still reports three pre-existing schematic violations; no PCB/hardware approval.

Scope, architecture and cost: software synthetic only, no RF/inductive/thermal/FOD/EMI/lithium/dock experiments or commissioning cryptography. Cable remains the baseline, regulated WPT a low-consumption hypothesis, simple open-loop WPT unapproved, dock charging independently blocked, ESP-NOW/OpenThread competing data links (not power), WISP only for truly tiny sensors. No radio for emergency stop. Incremental hardware BOM €0, engineering time excluded; Diotronic is auxiliary and local pricing/MOQ/stock unverified. Next physical gate requires explicit safety protocol/authorization: isolated resistive receiver/reader characterization without battery or station.


Latest: W-IND-96 — exact-integer protocol fields and finite watchdog (1 Nov 2026)

Published: commit 30524b69 · code, 10 adversarial tests, source audit, decision matrix, BOM and evidence. This modifies only own W Python code and tests on the existing PR #9 branch; it does not touch OOMWOO, #79, OEM Xiaomi, batteries, docks, CAD or third-party code.

Material defect discovered: bool is a Python int subtype: previously kind=True, session=True, seq=True and value_milli=True were silently accepted as protocol numbers. Worse, ModuleReceiver(7, float("inf")) accepted an effectively infinite data watchdog, and ModuleReceiver(7, True) accepted an unintended 1-ms timeout. max_attempts=float("nan") was also accepted in the sender policy. The fix requires the exact int type for every wire identity, payload number, session, local commissioning value and retry/watchdog configuration, raising ValueError before state mutation. Ordinary 22-byte packets, CRC16, ACK retries and freshness intervals are unchanged.

CI VERIFIED (same SHA 30524b6): 10 new adversarial tests + 441 existing = 451/451 PASS in general GitHub CI #41304531918 (logs checked); W60 ACK CI PASS #41304532073 (26 ACK tests + general regressions), W61 crypto CI PASS #41304532235 (29 auth + 14 W93 tests). Independent blocker: KiCad W18 native ERC #41304532108 FAIL, 3 violations; no hardware approved. Evidence is SYNTHETIC SOFTWARE ONLY; no radio, power or battery tests.

BOM: incremental hardware cost €0, software/CI labor not priced; Diotronic auxiliary and unverified, TME/Mouser/DigiKey prices/stock pending for eventual isolated test bench. Dock lithium/BMS and station isolated and blocked; module WPT requires FOD/thermal/offset/EMI/cut independent validation. ESP-NOW and OpenThread are alternatives for DATA only, WISP for tiny sensors. No WPT motors/pumps; no radio critical stop. Next meaningful work needs a safe, isolated dummy-load bench and explicit approval.


Latest: W-IND-95 — invalid telemetry clock cannot generate re-ACK or fake freshness (1 Nov 2026)

Published and tested: commit 1a285d00 · W95 code, matrix, BOM and reproducibility · general GitHub CI PASS: 441/441 · W60 ACK recovery CI PASS · W61 authenticated application CI PASS.

Actual defect in experimental telemetry code (not deployed): AckTracker.retry previously compared unvalidated timestamps; NaN could emit a retransmission and corrupt retry timing, while nonnumeric input could throw a TypeError. Python booleans could be misread as millisecond timestamps when starting or accepting ACKs. The receiver could be commissioned with NaN or mark a boolean clock as a fresh reading. Fix: exact integer time validation at the five boundaries, fail the pending transaction on malformed retry/ACK time and reject invalid commissioning before state modification. Existing protocol, 60-ms retry, 240-ms ACK expiry, 250-ms freshness and authenticated application recovery remain unchanged.

Evidence: nine new deterministic adversarial tests (NaN, infinity, float, bool, text, None, object, recovery), 432 existing + 9 = 441/441 PASS in general Python workflow; W60 and W61 regressions PASS on the same SHA. These are software tests, zero real radios, zero physical experiments, zero battery/dock energizations. This patch is no physical safety authority or cryptographic provisioning.

BOM: €0 extra hardware for the patch; engineering/CI time not priced. Diotronic local quantities/IVA/availability and TME/Mouser/DigiKey comparison remain pending. No components purchased. Physical blocker unchanged: W18 native ERC on this SHA still FAILS with three violations (1 dangling label, 2 undriven power pins); WPT/FOD/thermal/offset/EMI/cutoff and the first sensor's real power remain unqualified. The next useful step is an isolated, authorized, resistive-only reader/RX bench measurement, not further idealized models. Own W sector only; cancelled Xiaomi OEM, OOMWOO and PR #79 untouched.


Latest: W-IND-94 — bounded duplicate-ACK regression fixed (1 Nov 2026)

Published: commit 05a9eec7 · W94 specification, adversarial tests, BOM and dependency audit · general PR CI PASS: 432/432 · W60 CI PASS.

Actual defect: previous general CI failed 1/429 because a legacy test required refusing a duplicate application packet, contradicting W60's intentional maximum-two authenticated re-ACK recovery for a lost ACK. The regression now verifies exactly two re-ACKs, no third, no second delivery and no artificial refresh of telemetry age. Three new adversarial tests reject nonboolean authentication flags without spending ACK budget, reject same-sequence changed payload, and prove duplicate ACK cannot extend the 250-ms freshness lease. No production protocol/code altered; no new hardware (0.00 EUR incremental BOM). The confirmed run contains Ran 432 tests ... OK.

Independent preexisting hardware blocker: W18 native KiCad ERC CI remains FAIL with 3 schematic ERC violations, ERC_HAS_VIOLATIONS_DO_NOT_BUILD; it is not corrected by W94. No PCB/charging safety approval.

Limitations: only deterministic synthetic software tests; no RF hardware, real WPT, sensor load, FOD, temperature, EMI, offset, electrical cut or battery/dock trials. External creators' revisions, branches and licenses checked against 28 Oct pins (WISP 640kHz diverges; OpenThread +21 commits). No borrowed sources, no edits to OOMWOO/#79 or other workers. Diotronic auxiliary, local stock/prices unverified. Wired serviceable fallback remains baseline.

Next: when explicitly authorized with a safe isolated resistive bench, measure receiver + reader energy and real authenticated ACK retries; no lithium/battery connection.


Latest: W-IND-93 — strict application-ACK authentication flag (1 Nov 2026)

Published: commit 1e8ee0dd · W93 original code, 14 adversarial tests, synthetic evidence, specification and supplier/owner audit · PR CI PASS: 96/96 W01/W60/W61/W93 · push CI PASS · synthetic JSON artifact #13078208153.

Reproducible defect fixed: w_link.AckTracker.accept_ack previously used if not authenticated_transport, accepting a CRC-valid ACK with truthy nonboolean authenticated_transport="false" (or 1/object), incrementing acked despite absent verified authentication. Changed it to authenticated_transport is not True (matching ModuleReceiver). Bad flags now preserve outstanding frame; valid explicit True after genuine caller-side HMAC verification still succeeds. Strict type acceptance is not cryptography; literal True cannot authenticate itself. No change to 22-byte frame/240-ms expiry. Reused existing W61 workflow, added W93; 27+26+29+14 = 96 tests PASS, synthetic JSON assertions and upload verified.

Known independent general CI failure: legacy wpt-sensor-v01-python run still FAILS 1 of 429 on test_power_restart_gate.test_seq_duplicate_on_same_epoch: old expectation disallows duplicate ACK while current W60 receiver allows bounded re-ACK without redelivery. This was present before W93 and is not resolved or claimed green. W61/W93 dedicated CI PASS.

Hardware and licensing: entirely digital software only; no radio, physical WPT, RFID, FOD/heat/offset/EMI, USB isolation or safe independent cut demonstrated. No battery/BMS/dock/motors connected, purchases or OEM work. Diotronic is auxiliary; local stock and exact IVA+shipping/MOQ unverified. Cable replacement is baseline. External author HEADs checked versus 28 Oct registered SHAs: Simple Wireless Power / WISP HW / ESP-NOW unchanged; WISP FW 640kHz diverged (+68/-11); OpenThread +21. No borrowed code/CAD, no upstream/other workers' files or OOMWOO #79 changed.

Next: authenticated RF-on-hardware ACK/retry energy/latency and isolated low-power receiver/reader characterization, only with independently reviewed bench safety plan and explicit authorization. No new hardware approval.


Latest: W-IND-92 — buffered rail energy ledger (1 Nov 2026)

Published commit e3ddb5cf · W92 source, tests, specification, BOM and source audit · push CI PASS · PR CI PASS · JSON evidence artifact #13074964245.

Material correction to W84/W91: RX output/load energy > TX input over a short burst does NOT automatically prove impossibility when a previously charged local capacitor supplies the difference. W92 propagates voltage, capacitance and energy uncertainty to account for the change in capacitor storage, or detect an incompatible/ambiguous ledger. In a fully synthetic 100±2 µJ TX /120±2 µJ load example, naive 120% changes to 76.219–99.712% conditional RX-rail to TX energy ratio, with C=1000µF ±5% and ΔV -10mV ±1mV/endpoint. It does not measure RF coil efficiency or prove a batteryless sensor. 25 new adversarial digital tests; W88–W92 99/99 PASS in push+PR CI (23+12+12+27+25), deterministic JSON SHA verified. Original software, no borrowed CAD/code.

No hardware release: W84 CSV provenance alone, W91 USB/I2C backfeed hazards, unknown ESR/leakage, buffers, calibration, offset, FOD, heat, humidity, EMI and independent fail-OFF cutoff require independent bench evidence. All battery/BMS/dock and motor/pump tests remain disconnected/not authorized. No purchases or OOMWOO/#79 changes. Cable replacement remains economic baseline; Diotronic stock/price pending. Head of this PR is the sole W publication target; local dirty shared Valdo checkout was untouched.

Next discriminating evidence: one reviewed RF-only receiver/reader cycle with fully isolated V_EH, measured reserve start/end, time-aligned TX+load energy and sufficient bandwidth for RF bursts, using only permitted isolated resistive bench after a safety procedure and explicit authorization.


Previous: W-IND-91 — prevent false batteryless claims caused by USB-powered NUCLEO (1 Nov 2026)

Published W-only commit 251319e4 · original source, 27 adversarial tests, specification and Diotronic-auxiliary BOM. Reused the W88-W90 workflow to run W88+W89+W90+W91 regressions (74/74 PASS: W88 23 + W89 12 + W90 12 + W91 27; PR dedicated CI PASS #41282600805; evidence JSON artifact #13073454384), verify deterministic W91 SHA256 and upload synthetic JSON. Historical older CI/ERC issues are independent.

Material manufacturer schematic finding: ST UM2960 Rev2 shows NFC07A1 jumper ST1 selects chip ST25DV64KC VCC from external 3V3 or EH, not RF power for an attached NUCLEO MCU or another sensor. The ST kit can appear successful under USB/3V3; without isolating I2C/GPO/backfeed and documenting an external V_EH-to-sensor path it is not proof of a batteryless module. Reader low-power card detection need not imply continuous RF; tag's V_EH can be high-Z under insufficient field. Risk only, no physical fault demonstrated. W90's EUR108.73 VAT-inclusive two-NUCLEO basket is external-power evaluation hardware, not a measured RF-only sensor prototype. RX tag is 64KC, not 04KC used for ST curves in W85-W89.

Novel digital safety gate: original fail-closed Python topology evaluator + 27 adversarial tests for ST1, EH enable, reader field mode, USB/3V3, potential signal backfeed, RX identity, VEH load path and unsupportable NUCLEO-energy claim. All cases yield hardware_release=BLOCKED. Output is synthetic; declarations eh_load_iv_measured=True do NOT attest actual measurements. Avoid purchases, energization, lithium, hardware installation. Tag autonomy requires isolated authorized V_EH/I_EH, cold-start, reader input, RF/ACK, FOD/temp/EMI/offset and independent electrical cut measurements; cable remains baseline.

Supplier and ownership audit: DigiKey web SKU prices from W90 (reader EUR41.08, tag EUR18.57, MCU EUR24.54 each, IVA21%, no shipping). Diotronic Zaragoza inventory/prices/MOQ and TME/Mouser exact basket still unverified. Four author projects/five upstream HEADs compared to baseline 28 Oct: simple-wireless-power GPL3 unchanged, WISP HW BSD2 unchanged, WISP FW 640kHz BSD2 diverged +68/-11, ESP-NOW Apache2 unchanged, OpenThread BSD3 +21; OOMWOO main f01a1b29 unchanged. Zero upstream code/CAD copied, OOMWOO #79 and other agents' checkouts/files untouched. Battery/BMS/charger dock disconnected and physical approval blocked. W91 BOM/decision and full URLs.


Latest: W-IND-90 — priced actual NFC reader+tag evaluation chain and exact-device mismatch (1 Nov 2026)

Published W-only commit 4069c4ed · W90 code, 12 original adversarial tests, spec, BOM/decision, creator HEADs, deterministic JSON SHA256. Existing W88/W89 dedicated CI reused for W90 (35 historical tests + 12 new = 47 if all succeed), no new workflow. CI verified PASS: PR run #41279293687 (W88 23 + W89 12 + W90 12 = 47/47 tests, SHA256 checks PASS), reproducible W88/W89/W90 JSON artifact #13072551806. Dedicated workflow PASSED; this does not green historical unrelated general CI/old ERC.

Material finding: ST maker-active NFC-V reader X-NUCLEO-NFC08A1 (ST25R3916B, 47×34mm antenna) and X-NUCLEO-NFC07A1 tag board (ST25DV64KC, 54mm antenna) are real candidates for a low-power isolated evaluation kit, not approved power links. The old NFC06A1 reader board is obsolete at DigiKey. The tag board is 64KC, not ST25DV04KC used in W85–W89, so transferring the 22 ST sample output V/I values as though they apply to this board is invalid. ISO15693 common support does not verify energy transfer, coincident data, or a system.

Verified 1-Nov online DigiKey ES SKU prices (21% VAT, excl. shipping): NFC08A1 €41.0795, NFC07A1 €18.5735, optional STM32 NUCLEO-L476RG MCU host €24.5388/each. Reader+tag+one MCU €84.19; two hosts for an explicitly distinct two-sided telemetry development scenario €108.73, only board subtotal, not a working/safe test bench. Missing isolated source, instrumentation/calibration, resistive dummy load, RF/ACK testing, thermal/FOD/EMI/independent cutoff and assembly/delivery. This is not the final unit BOM nor a claimed optimum. Cheap SO8N 04KC bare IC (~€1.12 incl VAT historically) is not a complete RFID/EH module. Diotronic Zaragoza local stock unconfirmed; TME/Mouser exact basket and delivery unverified. No purchases.

Owners/licensing checked: maker's GPL3 Simple Wireless Power unchanged; BSD2 WISP HW unchanged, WISP FW 640kHz branch diverged +68/-11; Apache2 ESP-NOW unchanged; BSD3 OpenThread +21 commits from Oct28 registered SHA. OOMWOO main f01a1b29; Valdo master 8a6030b. No external code copied, no OOMWOO upstream or #79 changes, no shared dirty local checkout modified, battery/BMS disconnected and no energization.

Decision: consolidate digital work, prefer simple replaceable cable until actual sensor, full budget and authorized isolated one-point V_EH/I_EH+reader energy/ACK measurement, offset/thermal/FOD/EMI/cut safety. Dock WPT, module EH and RF data remain separated. No WPT motors/pumps; no RF critical stop.


Latest: W-IND-89 — source-voltage/precharge headroom gate corrects W88 optimistic NFC assumption (1 Nov 2026)

Published W-only commit: 2b1e0176. W89 code, 12 original adversarial tests, specification, BOM/decision matrix, author/HEAD audit and deterministic SHA256. Existing W88 dedicated workflow was extended rather than multiplying CI, to run both W88 regression and W89 and upload reproducible W88/W89 JSON. CI verified PASS on both push #41274932680 and PR #41274935937, including 23 W88 regression tests + 12 W89 tests, deterministic SHA256 checks and reproducible dual JSON artifact #13071500096.

Why material: W88 assumes an ideal precharged effective 1200 µF reservoir between 3.30 and 3.00V (1.134mJ) and one 1mJ+0.01mJ RF-blackout burst survives. ST AN4913 Rev2 p7 reports V_EH=3.30V and 2.310mW under its own loaded AM100 0.5 A/m setup; this does not establish an ability to charge a 3.30V reservoir through a regulated path. With an explicitly hypothetical fixed nonboost voltage drop 0.20V, reservoir voltage at that single ST sampled operating point reaches only 3.10V: 0.366mJ between 3.10 and 3.00V, 0.644mJ short of one assumed 1.010mJ event. It also misses the required 3.30V precharge. These are assumptions, not measurements or a physical maximum: ST EH is unregulated and its loaded voltage could change with current. Increasing C does not create source voltage headroom.

22 manufacturer points cross-checked: under the injected 0.20V drop, 1mJ event/second, 0.1mW baseline, 100ms blackout and 80% efficiency, 0/11 AM100 and 0/11 AM10 samples simultaneously satisfy positive voltage headroom, positive mean energy margin, and initial burst reserve. One AM10 sample has voltage headroom but lacks average energy. With a hypothetical zero-voltage-drop path, one AM100 sample could pass mathematically, not physically. Unqualified boost regulator outputs remain BLOCKED, not declared impossible.

Separation and safety: dock charging requires FOD/temperature/humidity/offset/EMI and independent local physical fail-OFF cut; battery/BMS disconnected; no motors/pumps WPT. Module NFC harvesting is only a possible optional noncritical microsensor; retained serviceable cable remains economic baseline. ESP-NOW vs OpenThread only data (ACK application, CRC, sequence, timeout, privacy, recovery); no radio safety stop. WISP5 only microwatt-scale sensors. No safety approval, original hardware testing, purchase, printing, soldering, OEM or upstream edits. Local checkout owned by other Codex agent dirty and untouched; no PR #79 cleaning-jobs changes.

Attribution and sourcing: creators of Simple Wireless Power (GPL3), WISP hw+fw (BSD2, firmware branch 640kHz diverged +68/−11 from Oct28 reference), ESP-NOW (Apache2) and OpenThread (BSD3, +21 commits) verified against registered SHAs and PR history in BOM_DECISION.md. Diotronic is auxiliary, not confirmed local stock; Farnell ST25DV04KC SO8N ~€1.12 incl VAT MOQ1, Rubycon nominal 1200µF ~€0.59 incl VAT MOQ1, excluding delivery. Reader/antenna/regulated cutoff cost, effective reservoir and total delivered bill unverified. No external code/CAD copied.

Previous: W88 commit, W88 dedicated CI success. Existing unrelated generic CI Python and W18 ERC historical reds not resolved.

Next useful evidence: real isolated authorized bench with dummy load ONLY, measured V_EH/I_EH under load, radio communication, offset, cold start, reader input energy, converter dropout/boost efficiency and independent protections. No physical tests, lithium/BMS use or purchase without safety procedure and owner authorization. Digital work should consolidate instead of indefinite idealised parameter sweeps.

Copy link
Copy Markdown
Owner Author

W-IND-03 publicado — brownout de WPT y telemetría obsoleta (28/10/2026)

Commit d2fc113ddd0b212e6cf9934d087627570a0dee03, CI push 40707414771 PASS 69/69, incluyendo 28 pruebas nuevas contra el protocolo w_link.py real.

El módulo power_restart_gate.py niega telemetría al arrancar, ante microcortes simulados de POWER_GOOD, termometría/FOD adversos, desaparición del monitor, reloj inverso, caducidad de datos o fallos del journal. Exige estabilidad continua y nuevo epoch local antes de aceptar mensajes; los frames de la sesión anterior no atraviesan el nuevo estado en la simulación. El componente no controla los cortes físicos del transmisor.

Bloqueo demostrable: el fake VolatileEpochStore pierde la historia tras un reinicio completo y permite reciclar un epoch. Por ello NO se aprueba despliegue hasta añadir registro NVM monotónico transaccional verificado bajo corte, provisión/autenticación de claves, local commissioning real, comparadores/cortes independientes y pruebas del TX/RX con FOD/temperatura. La batería, BMS y estación no se conectaron. BOM, matriz de decisión y límites en README_W_IND_03.md.

Autoría: solo código W original; ninguna modificación en OOMWOO #79, upstream, clones, CAD C o Xiaomi.

Copy link
Copy Markdown
Owner Author

W-IND-04: registro persistente anti-replay (28/10/2026) — CI verificada

Publicado en esta PR propia: commit HEAD 8d436115747f1b9034a054669f5eacda622de3ba.

Evidencia CI reproducible: GitHub Actions run #40714516910, job #122908433139 SUCCESS; log: Ran 91 tests in 0.771s, OK (69 anteriores + 22 nuevos). Hubo 20/20 tests del diario ejecutados adicionalmente en laboratorio aislado antes de publicar; las dos integraciones W-IND-03 solo se acreditan con la CI sobre el código real.

Cambio material: durable_epoch_store.py implementa EpochStore.claim mediante SQLite estándar, BEGIN IMMEDIATE + UPDATE condicionado + COMMIT, synchronous=EXTRA; exige provisión inicial explícita, nunca auto-regenera un diario desaparecido y rechaza replay después de abrir otra vez. 22 pruebas cubren corrupción, bloqueo, sesiones duplicadas/agotadas, carrera de escritores, fallo antes/después de commit, kill de proceso hijo con transacción abierta e integración con PowerFencedTelemetry.

Advertencias: esto es persistencia de host Linux/POSIX, NO flash ESP32 ni prueba real de brownout; las banderas de autorización/autenticación siguen siendo stubs, un rollback de copia válida de DB requiere ancla anti-rollback y no se garantiza hardware FOD/térmico. El banco inductivo, regulador, corte normalmente OFF, bobinas, EMI, termometría y precios UE siguen SIN seleccionar ni medir. Batería/BMS/dock desconectados. Ningún código de Belbin/WISP/Espressif/OpenThread/OOMWOO importado, ningún trabajo C/cleaning-jobs tocado.

Informe, matriz de decisiones y fuentes · BOM ampliada no comprable.

Siguiente hito: evaluación comercial documentada de dos parejas WPT reguladas de baja potencia, FOD/térmica independiente, disponibilidad UE y costes completos. No autorizar hardware hasta disponer de ensayos aislados con carga resistiva.

Copy link
Copy Markdown
Owner Author

W-IND-06 — candidato eFuse del lado receptor publicado (28/10/2026)

Commit propio 91b90d16fb202c0b91e2e44e1adc4085214064ec. Sin cambios en OOMWOO, cleaning-jobs PR #79, fabricantes ni el checkout local master ajeno.

Hallazgo: para el sensor exclusivamente hipotético (5 V, 0,4 W media, 1,5 W pico), un protector de corriente con mínimo 0,5/0,6 A resulta demasiado grueso para pretender un umbral 0,4 A. TI TPS259630 soporta ajustes 0,125–2 A y dispone de variante latch-off para TSD (TPS259631 auto-retry). Con ±10,4% máximos publicados, el límite nominal 0,4 A implica 0,3584–0,4416 A solo en modelo de umbral DC. Si se asumiera RX ≥4,5 V y pico 1,5 W, el consumo sería 0,3333 A: holgura 25,1 mA. Ni esta separación de márgenes ni el TSD integrado constituyen FOD del transmisor o desconexión segura, y el inicio/rizado/temperatura todavía podrían invalidar el candidato.

Evidencia reproducible: modelo, 30 tests nuevos, informe y comparación upstream, BOM incompleta honesta.

CI verificadas: push 40735600496 y PR 40735609816, ambas 147/147 tests PASS. No se ha probado hardware, FOD, bobina, batería, radio o cargador.

Bloqueador antes de cualquier integración: corte del TX normalmente OFF e independiente del MCU/radio, FOD con metal aun sin RX, temperatura externa TX/RX y funcionamiento con desalineación; no congelar dimensiones ni elegir litio.

Valdi320 commented Nov 1, 2026

Copy link
Copy Markdown
Owner Author

W-IND-104 — cierre de energía de ráfaga y recarga del buffer

Publicado en este ámbito W, sin tocar upstream ni el checkout local compartido.

Hallazgo: el cálculo previo de 36,28 µF nominales no incluía además la tolerancia mínima del 20 % del candidato de 47 µF. Con 20 % de tolerancia, 50 % de retención, 80 % de eficiencia de descarga y ventana 3,3–2,0 V, el nominal mínimo pasa a 45,36 µF. El candidato de 47 µF solo deja 3,6 % de margen energético y queda rechazado por NRND y ESR/fugas/derating no cualificados.

Con el punto exacto ST AN4913 Rev. 2 (AM10, 1 A/m, 1,035 mW) y un perfil hipotético de 0,20 mW idle + 5 mW/10 ms cada segundo, el modelo requiere 41,6 % de campo durante el tiempo de reposo. Al 50 % pasa condicionalmente (recarga 0,521 s de 0,990 s); al 40 % falla. La sensibilidad también rechaza 40 % de retención, 25 ohm de ESR y 30 µA de fuga. Son supuestos analíticos, no mediciones de una placa.

Se añaden 16 pruebas deterministas; push y PR CI pasan. No se ha realizado medición física ni simulación electromagnética; la potencia del lector se excluye. El dock oficial OOMWOO sigue siendo de contactos y no se modifica; PR #79 es cleaning-jobs y está fusionada, sin cambios WPT. Ningún código/CAD externo se copió. Batería/BMS desconectados; hardware_approved=false.

Bloqueo independiente: W-IND-18 KiCad ERC sigue FAIL con 3 infracciones; no se autoriza fabricar ni energizar.

Valdi320 commented Nov 2, 2026 •

Copy link
Copy Markdown
Owner Author

W-IND-105 — reader-inclusive NFC energy gate

Decision changed: do not add an ST25R3916B reader solely to power one NFC EH sensor. The previous W-IND-104 result was tag-side only; this milestone adds the reader-side reference.

  • ST25R3916B DS13541 Rev.11 Table 127 at 2.4 V: 14 mA typ / 23 mA max = 33.6 / 55.2 mW. Footnote 7 has RX/TX enabled but RFO segments disabled, so this is a chip-only active reference, not field-on system input.
  • ST AN4913 Rev.2: 22 exact ST25DV EH points. At 1 A/m AM10, 1.035 mW at V_EH becomes 0.67275 mW after the inherited 65% downstream assumption; with W-IND-104's 50% field duty over the 0.99 s off-window, average tag rail is 0.33301 mW. The reader chip reference averages 16.632 mW over the same period (49.94×).
  • Best AN4913 point (5.5 A/m AM10) yields 8.18545 mW while field-on / 4.05180 mW averaged, still 4.10× below the reader chip reference. All 22 points fail dedicated-reader break-even. Ideal tag counts are lower bounds only; mutual loading and RF drive are excluded.
  • Decision: NFC EH only opportunistically if the field is already required for ID/data and incremental RF input, tag loading and communication margin are measured. WISP5 deferred unless a UHF reader is independently justified. Active modules default to keyed connectors; dock remains serviceable contacts; critical stop stays hardwired.

Files: W-IND-105 report · model · tests · BOM · decision matrix · upstream audit

CI: W-IND-105 focused suite PASS with JSON artifact, and full WPT Python suite PASS with combined evidence artifact. Both successful runs include W-IND-105 tests. The full-suite tested commit is cafd4c0d70fa280dd9018a1f6536fa3ed78daaf1; the current branch head 511dde290705fa085c37e3e5d66fc2523087b76c only removes a redundant workflow file and does not change tested source or tests.

Limits: datasheet arithmetic only; no physical measurement, reader-input measurement, EM simulation, coil/FOD/thermal/offset/EMI qualification or hardware approval. Battery and BMS remain disconnected. No upstream repository, OOMWOO, dock, Xiaomi OEM or PR #79 source was modified.

WPT market screen (public listings checked 2026-11-02; not selected)

  • DFRobot DFR0362 TX+RX: 5 V / 1 A (max 1.2 A), 2–10 mm; vendor listing says up to 90% but this is not an independently measured robot efficiency. DigiKey Spain shows about 7.42 € incl VAT / 163 in stock; Opencircuit shows 9.50 € incl VAT / 106 external-stock / 5–7 days. Neither listing documents the complete robot-level FOD, thermal, offset, EMI and independent-cut chain. DigiKey · Opencircuit
  • Adafruit Qi TX + RX: transmitter 5 W max, 2–8 mm, 39.25 € incl VAT; receiver 5 V / 500 mA, 23.25 € incl VAT; total 62.50 € before shipping, both shown in external warehouse with 10–12 day delivery. The receiver uses BQ51013B. This is a useful low-power Qi experiment, not a qualified robot dock or independent safety cut. TX · RX
  • Diotronic Zaragoza: the local catalogue has the EM1190 Qi pad at 33.49 € incl VAT, marked available, 5 V / 1 A input and output, 100 × 100 mm. It is a consumer pad; no FOD/thermal/offset/EMI/independent cutoff evidence is published, and web availability does not prove shelf stock at Av. de Valencia, 5. EM1190
  • Simple Wireless Power author design: the author's README reports 81.3% at 100 W and 1–2 mm, but also ~20 W loss, capacitors reaching ~70 °C after five minutes, no TX/RX feedback/communication, and capacitor limits above roughly 5–6 A. These are author results, not our measurements. Original project
  • Regulated WPT: no controller/coil/FOD chain is selected or priced. Cost is deliberately left pending until documented FOD, temperature, offset, EMI, traceability and independent hardware cut are demonstrated. Contacts remain the repairable default for the dock and active modules.

No item was bought or tested. Diotronic remains auxiliary; the EM1190 listing is not a reason to alter the architecture.