Hyper VCU

INFO: This project is in early development. Many features are not yet fully implemented or tuned. Use on your own risk. Not every ESC combination is guaranteed to work

Application

DIY replacement vehicle controller for Joyor T6E scooters for use with VESC motor drivers and the original controls. Currently only supports Joyor T6E.

Features

  • Controls all lights: Front, Rear, Brake, Indicators
  • 3 Drive modes + 3 additional "master" drive modes (Adult/Child modes...)
    • Speed, Current and control mode (Throttle vs. Speed control) for every mode selectable
  • Configurable Off-throttle and Brake regen strength
  • R503 Fingerprint reader support
    • Locks scooter until valid fingerprint is scanned
    • Enables secondary drive modes with "master finger"
  • USB & OTA firmware update
  • VESC Control via UART
  • Reads charge level from original BMS via BLE
  • Configuration via WiFi webinterface (ESPUI based)
    • Connects to existing AP or fallback to standalonge AP mode (Password + Hidden SSID supported)

Connections

NOTE: NEVER connect or disconnect battery power when connected to the vesc or display. Always disable the battery using the JBD APP when connecting or disconnecting anything from the battery to prevent sparking or fault currents

Colors of different clone Julet style connectors can differ!

Joyor T6E pinout:

Display connector male side:

                     U - key
     U               1 -  48v_powon (yellow)
 2       1           2 -  vbat (red)
     6               3 -  gnd (white)
 3       5           4 -  (green uart 5V)
     4               5 -  (black uart 3.3V DISP RX)
                     6 -  (blue brake low)

Enable signal

Some ESCs have an enable pin on the comms connector that turns it off (after timeout) when pulled low. The enable pin of the HyperVCU is low when off and pulled via an optoisolator to VESC 3.3V when on to keep it enabled. Using this pin is optional and was tested on the MKESC 75100 V2 and MKESC 75200.

If this pin is not available but the ESC has push start with timeout it will be kept enabled by a uart keepalive signal.

Kill signal

AD2 can be used as a lock/unlock signal. It behaves like the enable pin but goes high (to VESC 3.3V) only after the VCU is unlocked (via Fingerprint) and not immediately.

Usage

Setup

  • Update VESC to a compatible firmware (>V6.06, V7.0 recommended)
  • Set up FOC, Hall sensors, calibration, wheel diameter (250mm), motor poles (30) in VESC tool
  • Test motor with VESC alone
  • DISABLE BMS WITH JBD APP
  • Connect lights, fingerprint reader, display, VESC, power...
  • Connect XT60 and enable BMS again
  • Power on, connect to webinterface
  • Configure drive modes and fingerprints

Access webinterface in standalone AP mode

  1. Connect to "Hyper VCU" wifi, default pw "hypervcu"
  2. Open "http://10.13.37.1" in a browser

Common usage

  • Enable/Disable zero start: Hold brake, push throttle up quickly to 100% and release. "!" icon should appear
  • Zero start and master modes reset to startup behaviour when enabling drive mode 0

With fingerprint reader

  • Unlock motor: Scan any valid finger
  • Enter "master modes": Scan finger with id <10
  • Exit "master modes": Scan any non master finger

Without fingerprint reader

  • Unlock motor: Unlocked on start
  • Enter "master modes":
    1. Enter pedestian mode (Hold drive mode "down" in any non zero drive mode)
    2. Hold brake and exit pedestrian mode (push throttle up for example)

Display + Errors

Display indicators

Display Meaning
bt n "P menu" Motor temperature
"!" Symbol Zerostart or Master mode active
Battery % Battery %
Speed Speed kmh

Error codes

Errors are bit masked. Multiple can appear at once.

Name Code
VCUERR_LOCKED (Fingerprint locked) 0x01
VCUERR_VESCNOK (Vesc error/Disconnected) 0x10
VCUERR_VESCTEMP (Motor or mosfet hot) 0x20

Screenshots

Drive page Mode page System page

T6E Protocol

From Controller to Display

Byte IDLE Info Note
0 0x02 start
1 0x14 start2?
2 0x03 start3?
3 0x00
4 0x00 0x20 “!” symbol
5 0x80 Brake Brake 0xA0
6 0x00
7 0x00
8 0x00 speed high
9 0x00 speed low in 0.1kmh 0-99kmh
10 0x00 Battery in %
11 0x00
12 0x1E
13 0x00 errors
14 0x00
15 0x00 BT_n cycle count
16 0x00
17 0x00
18 0x00 Blinker pins 0x1 left, 0x2 right
19 CRC

From Display to Controller (5V)

Byte IDLE Info Note
0 0x01
1 0x14
2 0x03
3 0x00
4 0x00 Speed mode 0 Mode 1 = 5, Mode 2 = 10, Mode 3 = 15
5 C0 Flags Walk 225, Headlight 224
6 0x00
7 0x00
8 0x00
9 0x00
10 0x00
11 0x00
12 0x14
13 0x1E
14 0x00
15 0x00
16 0x00
17 0x00 throttle
18 0x00 throttle Maxval 1000
19 0x00 Blinker/Pin status 0x1 left, 0x2 right
20 CRC