feat(pcb): per-console power distribution + monitoring CAN node (PDU) — INA180 telemetry #202
Description
Body consolidated 2026-07-08 — the original exploratory scope (below-the-fold history in comments) converged over 6 comments into a built board. This body now reflects current state; the comment thread holds the decision history.
Status — boards built, firmware bench done; soak next
PDU rev 0.2.0 assembled (#351, closed) and running PDU_Left firmware; bench sections 1, 2, 6 (client) and 7 pass (2026-10-23 update below). Remaining: sections 3–5 against a real load in the soak (#291), test_node_telem. Next board revision: #352 (rev 0.3.0). Rev 1 is instrumentation-first: measure the real cockpit load and let that data size the final fuses and shunts. (The original status from 2026-07-08 — routed, DRC 0/0, PR #217 — is history.)
Role / architecture
- ~3 PDUs, one per console (Left · Right · Main Instrument). Each injects + monitors + fuses its console's power locally.
- Sits PSU → PDU → console
J_BUS. GND + CAN stay continuous across all PDUs; +12V/+5V are segmentable (a heavy zone dead-ends its OUT power pins → next zone gets a fresh injected feed). - Built on the PanelGroup base (STM32F103C8 + SN65HVD230 CAN + AMS1117) + design-block library (feat(pcb): OpenSkyhawk Design Block library (reusable power/CAN/MCU/harness circuits) #201). Own NODE_ID.
Locked design — as fabricated, rev 0.2.0 (see DESIGN-NOTES.md for full BOM/rationale)
| Function | Part | Note |
|---|---|---|
| Current sense ×2 | INA180A2 (SOT-23-5, gain 50) + 0.1%/25 ppm dividers → STM32 ADC | analog high-side; NOT INA219/INA226 (relaxed accuracy → cheaper, inspectable SOP; INA219 = documented fallback if absolute-V ever needed; INA3221 QFN-banned) |
| Shunt ×2 | 10 mΩ 2512, 3 W, ±50 ppm/°C (RES-0R010-1PCT-2512, LCSC C2903468) |
Kelvin (4-terminal) via pad routing; re-sourced from C346481 / C500740 (both dead, see 2026-10-01 update) |
| Voltage sense | dividers 12 V 33k/10k · 5 V 10k/13k, after the fuse (load side) | rail-V + fuse-open detect (12 V; a blown F2 takes the PDU's own 5 V with it). 0.1 % on the ratio resistors from rev 0.3.0 (#352) |
| Temp | NTC B3450 ±1% + STM32 internal sensor | TMP117 dropped (WSON-banned) |
| Fuse ×2 | 12V 5 A · 5V 2 A MINI blade + holder | source-side, off-board consumable; GND never fused |
| PSU input | Mini-Fit Jr 4-pin 2×2 — J1: +12V_IN / +5V_IN / GND / GND | J_PSU_IN |
| Bus | J2 BUS OUT Mini-Fit Jr 8-pin (1–2 +12V, 3 +5V, 4/7/8 GND, 5/6 CANH/CANL — same as the PanelGroup / Gateway J_BUS) · J3 CAN IN Mini-Fit Jr 4-pin 2×2 (CANH / GND / GND / CANL; → CANH / CANL / GND / GND in #352) | CAN IN is for a run that carries CAN without power; same housing as J1, so the harnesses can be swapped (#352 makes GND line up) |
| Input TVS | D1 SMBJ12A (12V) · D2 SMBJ6.0A (5V, LCSC C5331096) | per the #214 input-rail standard |
- Copper: large pours (12V 6–10 mm / 5V 5–8 mm / GND max, via-stitched) — sized for Kelvin accuracy + thermal margin, not current (a console is ~2–3 A). Fuse-aware neck rule: ≥2 mm per-console, ≥5 mm whole-bus — documented in
docs/_source/base-boards.md§ Pour sizing +base-boards-power-pour.svg. - Servo power:
12V rail → local buck → servos, never logic 5V (+ bulk cap + polyfuse). Servos become a 12V load (captured by the 12V INA180); keeps 5V monitoring clean. Inhardware-standards.md. - Fault flags (TELEM_n, as built in feat(firmware): PDU monitoring node — telemetry firmware + new CAN telemetry packet class #216): per rail
UNDER_V·OVER_V·OVER_CURRENT·FUSE_OPEN(12 V) ·SENSOR_FAULT; boardUNCAL_VDDA·UNCAL_ZERO·TEMP_WARN·TEMP_CRIT·NTC_FAULT. The worst one also goes toHEALTH_n.faultId; CAN health is reported by the node-status frames, not a PDU flag.
Remaining before this closes
- Merge PR feat(pcb): PDU power-distribution + monitoring board (#202) #217 (PCB) + PR docs: docs-drift cross-check → GitHub Projects; power per-console fusing #212 (power docs) — merged 2026-07-04 / 07-05.
- Order SMBJ6.0A (C5331096) for the 5V position (12V stays SMBJ12A); confirm the 12V bulk cap ≥ 25V — D2 fitted as SMBJ6.0A; C9 is 22 µF / 35 V electrolytic (
CAP-ELEC-22UF-35V-D5). - KiCad touch: swap D2 schematic symbol SMBJ5.0A → SMBJ6.0A — D2 reads SMBJ6.0A / C5331096 in the schematic.
- Receive boards + components → hardware bench verify — received 2026-10-18, assembled (chore(hardware): assemble + pre-firmware power-up — Rev 0.2.0 PanelGroup B, Gateway/Bridge, PDU #351), firmware bench 2026-10-23; load-side checks continue in the soak (test(hardware): soak test panel — panel-mount controls on a printed or laser-cut faceplate, harnessed to two PanelGroups #291).
- Docs: servo-power standard →
hardware-standards.md(12 V + panel-local buck); 12V load-budget refresh →docs/architecture/power.md(~6–8 A with servos). - Docs: commit the PDU pour widths — the fuse-aware neck rule is in
docs/_source/base-boards.md§ Pour sizing (+base-boards-power-pour.svg).
Split off / related
- Firmware → feat(firmware): PDU monitoring node — telemetry firmware + new CAN telemetry packet class #216 (telemetry node + new CAN telemetry packet class).
- Enclosure — tabled (mount undecided).
- Related: feat(pcb): OpenSkyhawk Design Block library (reusable power/CAN/MCU/harness circuits) #201 (design blocks) · feat(pcb): bus power distribution + power spec (base boards) #203 (power spec/PSU, merged) · docs: docs-drift cross-check → GitHub Projects; power per-console fusing #212 (power docs) · feat(pcb): PDU power-distribution + monitoring board (#202) #217 (PDU PCB) · docs(hardware): input-rail TVS fleet standard (SMBJ12A/SMBJ5.0A) #218 (TVS docs) · feat(pcb): central PSU power-entry / distribution board (24-pin ATX -> 3x console feeds) #215 (optional central PSU entry board) · feat(hardware): standardize input-rail TVS protection across CAN-node boards #214 (input-rail TVS standard, closed).
Update — 2026-09-21 (Firmware v0.2.0 milestone)
- Boards are on hand; assembly + bring-up is the first half of Firmware v0.2.0, with the PDU firmware (feat(firmware): PDU monitoring node — telemetry firmware + new CAN telemetry packet class #216) designed alongside.
- Assemble Rev 1 with SMBJ6.0A in D2 —
mainchanged it from SMBJ5.0A on the same footprint, so it is a BOM swap, not a respin. Same for C8 (10 µF → 100 nF, same 0805 footprint). - C9 stays the as-fabbed 10 µF 0805; the 22 µF/35 V electrolytic on
mainneeds a new footprint → part of the post-v1 protection respin tracked on Prototype PCBs: base boards (Gateway/Bridge + PanelGroup base) #95.
Update — 2026-10-01 (PDU rev 0.2.0 boards ordered)
Ordered alongside the PanelGroup Rev 2 run in #209, since both had diverged from their fabbed
revision and neither had been assembled.
- JLC
W2026093021050394(InvenTree PO-0018) — PDU rev 0.2.0 ×5 (Y23) + a 130×100 top-only
solder-paste stencil (SO12609300758). Arrives ~Oct 15–22. - LCSC
WM2610010130(PO-0019) — PDU shortfall covered: INA180A2 ×10, fuse holders ×20,
10 mΩ shunt ×20, 1 kΩ ×100, 1.5 kΩ ×100, 100 nF ×100.
Pre-fab gates: ERC 0 · DRC 0 violations / 0 unconnected / 0 schematic parity · silkscreen gate
passed (connector pin labels were already complete — 24 pins checked against their nets; only the
revision text needed reformatting to REVISION 0.2.0 | POWER DISTRIBUTION UNIT).
Shunt re-sourced — RES-0R010-1PCT-2512 had no live supplier. C346481 went out of stock
2026-07-10 and its replacement C500740 followed on 09-30. Now sourced as C2903468
(HoJLR2512-3W-10mR-1%, 2512, 3 W, ±50 ppm/°C, molded alloy non-inductive), added as an alternate
on the same IPN with both dead SKUs marked inactive, and set as the KiCad LCSC field on R1/R2.
Tempco history is C346481 ±100 → C500740 ±25 → C2903468 ±50. A step down from what it replaces, but
still better than the ±100 ppm this design originally accepted — and irrelevant against the real
error budget, where the shunt's own ±1 % tolerance (±30 mA at 3 A) is five times the ±50 ppm term
(±6 mA over 40 °C) and Vrefint contributes more again. 5× C500740 are already in stock, enough
for two PDUs, so nothing is blocked.
Rating on R1/R2 also corrected 2 W → 3 W to match the part actually fitted.
Fuses are still not a tracked part. F1/F2 are holders (XF-508P-B-B, C19727305) and the BOM
lists only the holders — nothing records what goes in them. Ratings are decided in
PCB/Base/Power/PDU/DESIGN-NOTES.md: F1 = 5 A on 12 V, F2 = 2 A on 5 V, standard MINI blade
(ATM/APM — not low-profile APS, which is the common mis-buy). Treated as an automotive consumable
bought outside InvenTree, but worth surfacing on the BOM or silk so an assembler sees it.
- Receive PDU rev 0.2.0 boards + stencil — PO-0018 complete 2026-10-18
- Assemble PDU rev 0.2.0 — powers up (30 mA on 5V, no firmware); BO-0016 complete — chore(hardware): assemble + pre-firmware power-up — Rev 0.2.0 PanelGroup B, Gateway/Bridge, PDU #351
- Source MINI blade fuses: 5 A (tan) + 2 A (grey)
Firmware bench, accuracy and tuning on the PDU — carried from #216 (PR #343, merged)
The PDU firmware (PowerMonitor, Firmware/Panels/PDU_Left|Right|Center) is merged. Its logic and
the sampling path are proven on a non-PDU STM32F103 (logic tests 106/106, real-bus smoke, 1000
scans/s, calibration survives a reflash) — the measurements themselves are not. These steps
prove them on the real board, per PDU, before the v0.2.0 tag. Equipment: multimeter, a known load
(power resistor or electronic load) with an ammeter in series, a thermometer. Paper accuracy after
calibration: voltage ≈ ±0.5 %, current ≈ ±1.5 % + 10–20 mA — the bands below have margin over that.
1 — Bring-up
- Flash the console's sketch (
PDU_Left= 3,PDU_Right= 4,PDU_Center= 5); DiagSerial (115200) boot banner shows the right NODE_ID; the node appears in the client roster — PDU_Left: NODE_ID 3 confirmed on CAN (HB/HEALTH 0x103/0x143, kind PDU) rather than from the banner, which wasn't captured; in the client roster as PDU_Left prototype: replace Arduino Mega injector with RP2040 #3 -
RAWbefore calibration: rails read near 12 V / 5 V, temperature near room,scans/s≈ 1000 — 12.263 V / 5.052 V, 27.0 °C, 1000 scans/s
2 — Calibrate (once per board; survives reflashes)
- Measure the 3V3 rail with the DMM →
CAL VDDA <mV>;CAL SHOWreports VDDA = yes and a Vrefint between 1100 and 1300 mV — DMM 3304 mV → Vrefint 1209 mV - Console load disconnected →
CAL ZERO; it accepts (raw zero under 75 mA on 12 V / 120 mA on 5 V) andCAL SHOWreports ZERO = yes — raw 14 mA / 57 mA; zero12dmA=149, zero5dmA=576
3 — Accuracy against the meter (record PDU vs meter for each)
- 12 V rail: PDU
vAvgvs DMM at the bus-out connector — within ±100 mV - 5 V rail: same — within ±50 mV
- Idle current after
CAL ZERO: both rails within ±20 mA of 0 — 12 V ±1 mA, 5 V 0 mA - 12 V current at ~0.5 A and ~2 A known load vs the series ammeter — within ±(1.5 % + 20 mA) — waived: no load or ammeter on the bench. The 12 V channel has never carried current — first look in the soak (test(hardware): soak test panel — panel-mount controls on a printed or laser-cut faceplate, harnessed to two PanelGroups #291)
- 5 V current at ~0.5 A and ~1.5 A — within ±(1.5 % + 20 mA) — waived: no reference load. Plausible: tracks real load steps (blank PanelGroup +44 mA, Gateway STM32 +18 mA, PanelBridge board +16 mA)
- Board temperature vs a thermometer at the NTC, at room temperature — within ±1 °C — waived: no thermometer. Plausible: NTC 25–27 °C at room temperature
- Out of band → set the gain trim / NTC offset and re-check — not needed: nothing measured out of band (bench-only for now:
CalRecordhasiGain*/vGain*/ntcOffsetDCfields but noCALcommand sets them yet — add one in a small follow-up PR if a board needs it)
4 — Fault behaviour
- Pull the 12 V fuse →
FUSE_OPEN+UNDER_Vflags on the 12 V page within ~1 s; the node turns amber in the client; refit → clears - Load above the over-current threshold for > 100 ms →
OVER_CURRENT; below 90 % → clears after ~0.5 s — waived: no safe 4.5 A / 1.8 A load on the bench
6 — End to end
-
Tests/PanelBridgetest_node_telem(USB-UART adapter on PA2/PA3 @ 250000, any STM32 board) — covered by the end-to-end run: real PDU frames → real PanelBridge →_NODE_TELEM→ client. The sketch's drop / liveness edge cases weren't run on hardware - PDU telemetry visible end to end in the client → acceptance of feat: node data layer — PDU telemetry, node mapping, new-node detection SkyHawkClient#61 —
_NODE_TELEMlines on the SimGateway CDC; client Cockpit tab matchesRAW(12.30 V / 5.04 V / 0.09 A / 25 °C)
7 — Client cockpit checks with a real PDU (carried from SkyHawkClient fix-track chunk 2, OpenSkyHawk/SkyHawkClient#131; built and covered by automated tests, never run against a real PDU). Run with the client build from main once chunk 2 is merged.
- A new PDU on the bus opens the Adopt dialog wherever it's clicked (never a board panel)
- After adopting, a PDU that goes offline still reads as a PDU (its reported kind is stored) — PDU held in reset with SW1: only PDU_Left dropped, still shown as a PDU, its boards stayed linked
- Power-zone pickers offer only PDUs in your cockpit (hidden ones included); Add all / pre-fill give "No power zone" when the default PDU isn't added — picker checked on the real PDU (hidden one listed with a "hidden" label); Add all / pre-fill covered by the earlier fake-data run
- Hide the PDU: its boards keep their links; it never reads "(not added)"
- Forget is refused while the PDU is online (incl. while only its telemetry arrives) and right after a reconnect; allowed offline, and it unlinks its boards — real PDU: disabled online, enabled offline, unlinked both boards, PDU returned as new; telemetry-only and just-reconnected cases covered by the fake-data run
- The Forget note's fed-board count includes hidden boards — real PDU showed 2 fed boards; the hidden-board case is covered by the fake-data run
- Importing a config whose boards link to a PDU outside your cockpit brings them in as "No power zone", and the preview says so — fake-data run only; not repeated on the real PDU
Update — 2026-10-22 (PDU 0.2.0 assembled + powered)
PDU 0.2.0 assembled alongside the PanelGroup and Gateway (record in #351): SMBJ TVS D1/D2 were fitted reversed (footprint issue, below) and flipped before first power-up; it then drew 30 mA on 5V with no firmware. Firmware bench (sections 1–7 above) runs in its own worktree session. As fitted: R5 and R20 both 0.1 % 10k; R14 fitted.
PDU — next revision
Moved to #352 (PDU rev 0.3.0): crystal load caps to GND, GND-compatible J3 CAN IN pinout, precision resistor fields, connector legends, fuse ratings on BOM/silk. The TVS item is dropped — the reversed TVS were an assembly misread of the cathode dot, not a footprint defect. Full PSU IN / CAN IN swap-proofing is tabled as a Notion idea.
Update — 2026-10-23 (PDU 0.2.0 firmware bench, PDU_Left)
Sections 1, 2, 6 and 7 pass on the real board; section 3's load and temperature checks and the over-current check are waived (no reference equipment). Tuning against a real console load (old section 5) and the full-console power-up check are removed — no real console exists to test against; the PduConfig.h defaults stand. Left (next bench session): 12 V and 5 V vs the DMM (probe C9 / C10 to GND) and the F1 fuse pull — then this issue can close.
Rework needed to bring it up — none of it firmware:
- R18 (33 Ω SWDIO series): dry joint → SWD couldn't connect. Reflowed.
- J6 (DEBUG SERIAL): pin 2 (TX) shorted to pin 3 (GND) from the earlier connector rework. Cleared.
- HSE didn't start (
RCC_CRHSERDY = 0 → firmware CLOCK FAULT, CAN at ~111 kbps instead of 500k). Design bug, below. Bodged C21/C22's shared node to GND (C19 pad 1) → 72 MHz, CAN 500k.
Bench numbers (calibrated, PanelGroups fed through J2): 12 V 12.27–12.30 V, 5 V 5.04–5.06 V, NTC 25–27 °C, 1000 scans/s, flags clear. The 5 V INA180 tracks load steps (blank PanelGroup +44 mA, Gateway STM32 +18 mA, PanelBridge board +16 mA; PanelGroup with firmware ≈ 70 mA). The 12 V current channel has not seen a real load yet — first check in the soak.
Bench gotcha: an ST-Link with its 3.3 V wire on a board's SWD header feeds that board's 3V3 from USB (~35–40 mA here) and hides it from the PDU's 5 V reading. Leave the 3.3 V wire off for any power measurement.
C21/C22 detail and the bodge are in #352. Every PDU 0.2.0 board needs the bodge (C21/C22 shared node → GND). Gateway, PanelGroup, ASN-41 and Armament_MCU crystals checked — correct.
Activity
feat(pcb): bus power distribution + power spec (base boards) (#203)
mottihoresh commentedon Jun 30, 2026
PSU selected + power spec documented (PR #203)
Source PSU: GOLDEN FIELD NX650 — 650W, 80+ Gold, fully modular, DC-DC, ~$60. Over-provisioned ~13× (cockpit ≈ 50W); chosen for clean modular cabling + expansion headroom. DC-DC topology → no minimum-load resistor needed.
Constraints found (feed the injection + monitoring design)
Soft-power tie-in for this node
The monitoring MCU could run on +5VSB (always-on, 2.5A) and own PS_ON# control — giving a soft power button + AC-present sense + per-zone soft-enable, alongside the INA219 telemetry. Folds power sequencing into the same node.
Documented
docs/_source/base-boards.md→ new Source fusing & per-console injection + PSU / source supply sections (PR #203). The segmentable pass-through (jumper / DNP) design-in is reflected there so future boards stay re-injectable with no redesign.mottihoresh commentedon Jul 1, 2026
PDU design review — refined scope for the power node
Converged design after external review + load re-analysis. The node is now framed as a PDU (Power Distribution Unit) — a smart per-console power injection node, not a per-device distributor.
Architecture
base-boards.md). GND + CAN stay continuous across all PDUs.Rails monitored: 12V + 5V
3.3V is generated locally on each board (AMS1117) → no central 3V3 monitoring.
Current monitoring — INA226 (supersedes the earlier INA219 note)
One INA226 per rail (12V, 5V). Chosen over INA219 for an instrumentation board:
Power path + shunt
Temperature — TMP117
One digital temp sensor near (not under) the 12V shunt. Overheat detection + thermal-design validation for Rev1.
Fault detection (firmware, over CAN as a bitmap)
12V/5V UV · 12V/5V OV · overcurrent · fuse-open · sensor failure · CAN failure · temp warning · temp critical.
Copper — 2-layer, 1oz
Large pours (not traces): 12V ~6–10mm, 5V ~5–8mm, GND max + heavily via-stitched top↔bottom. Note the pours are sized for low-R (Kelvin accuracy) + thermal margin at the aggregation point, not current (a console is only ~2–3A). No narrow necks at connector / fuse / shunt / output.
Servo power — 12V→buck, NEVER logic 5V (new standard)
5–6 MG90 servos/console ≈ 2–3A running (up to ~6A stall) if put on 5V → brownout + I²C glitches + blows the 2-feed 5V budget. So:
Same power on 12V = ~1–1.5A (buck ~halves rail current) + isolated from logic. Servos become just a 12V load → captured by the 12V INA226; 5V monitoring stays clean. No dedicated servo PDU/output needed.
Revised per-console load budget
Corrected LED budget: 500 LEDs → 100× 5-series strings → ~3–4A total cockpit-wide (not 20A). Keeping servos off 5V also resolves the "+5V only on 2 IDE/SATA feeds" constraint.
Rev1 = instrumentation platform
Primary purpose is measurement, not optimization. Collect idle / startup / lighting / peak / normal current → let real data drive final fuse sizes, whether more/specialized PDUs are justified, shunt values, and rail separation. Revisit the 3-zone architecture after a few months of data.
PDU outputs (Rev1)
To do
hardware-standards.md(12V→buck, local cap + polyfuse, off-logic-5V).docs(power): fused per-console injection + refresh PSU/budget figures
docs(power): match #202 — +5V fuse blanket ~3-4 A
docs(power): pin fusing/segmentation to the fabbed 8-pin J_BUS
docs(power): injection granularity follows consumption (dedicated PDU…
docs(power): correct +5V blanket fuse to calculated 4 A (was 3 A)
mottihoresh commentedon Jul 3, 2026
State going into the PDU build — decisions from 2026-07-03 (docs in PR #212, unmerged)
Refinements this session that feed the PDU design. Docs updated in
docs/_source/base-boards.md+docs/architecture/power.md(PR #212).Resolved
J_BUS_INat each injection node, not a second board connector:J_BUS_OUT(its power pins dead-end → power never crosses the console boundary; CAN stays one continuous bus)Refined
5 mm of 1 oz external ≈ 7 A(IPC-2221 @10 °C;1 mm ≈ 2.5 A) → clears the 5 A/4 A blanket. The1 mm / 2.5 Afigure is a local sub-1 A tap only, never the fused trunk (it had contradicted the 5 A blanket — fuse > copper — now resolved). Pour-neck rule is fuse-aware: ≥2 mm per-console segment (≤~3 A), ≥5 mm whole-bus. The PDU's12V 6–10 mm / 5V 5–8 mmpours clear this comfortably (they're Kelvin-accuracy + thermal driven, not current).Build note — GND at injection (two sources)
At an injection node GND arrives from both the PSU return (fat, 18 AWG) and the previous node's CAN harness (thin, ~24 AWG). Same net. Keep the PSU GND as the dominant low-impedance return; treat the CAN-side GND as a reference tie only — else the thin CAN-GND wire carries power return it isn't sized for.
Stale in the body (for tonight)
INA219→ INA226 (per the 2026-07-01 design-review comment).Still open / not yet in any doc
12V → local buck → servos, never logic 5V+ bulk cap + polyfuse) → add tohardware-standards.md(already a to-do here).power.mdboard table (≤500 mA/board) + cockpit~3 Aare LED-only; servos-on-12V push cockpit to ~6–8 A.12V 6–10 mm / 5V 5–8 mm) live only in comments — not a committed PCB doc yet.mottihoresh commentedon Jul 3, 2026
PDU Rev1 — parts research complete, board scaffolded (2026-07-03)
Sensing/power-path parts locked and datasheet-verified. Board scaffolded at
PCB/Base/Power/PDU/on branchpcb/pdu-power-202; full BOM + rationale inPCB/Base/Power/PDU/DESIGN-NOTES.md.Locked BOM (per PDU)
ADC use 7/10 on F103C8 · sensing ≈ $0.70/board.
Key decisions (supersede stale body text)
FW carry-forward (bring-up)
Next
B2 schematic — stamp the reused blocks (STM32 core / SN65HVD230 CAN / AMS1117) from
PanelGroup_Base.mottihoresh commentedon Jul 4, 2026
PCB stage complete — PR #217 (2026-07-04)
Hardware deliverable done. PR #217 (
pcb/pdu-power-202→ main) — board routed, DRC 0/0, ERC-clean, 3D models.BOM closed — every LCSC datasheet-verified, new parts in InvenTree, reused parts pull LCSC from InvenTree (source of truth). Full table:
PCB/Base/Power/PDU/DESIGN-NOTES.md.Key part decisions (supersede earlier body/comments):
Split off:
Order status: bare boards ordered (JLCPCB fab, in transit). Components (LCSC parts, per DESIGN-NOTES BOM) pending — batched with the Right Nav LCSC order.
Remaining before this closes: merge #217 · receive boards + components · hardware bench verify. Firmware tracked separately in #216.
docs(pcb): fix PDU J_PSU_IN pinout + fuse/TVS designators to match fa…
feat(pcb): PDU power-distribution + monitoring board (#202) (#217)
2 remaining items
docs: docs-drift cross-check → GitHub Projects; power per-console fus…
docs(hardware): 5V input TVS SMBJ5.0A -> SMBJ6.0A (standoff margin)
mottihoresh commentedon Jul 6, 2026
5 V input TVS changed: SMBJ5.0A → SMBJ6.0A (2026-07-05)
Reason: 5.0A standoff (5.0 V) sits at nominal → leaks ≤800 µA near the +5 % rail corner (5.25 V). 6.0A (6.0 V standoff) clears 5.25 V → leakage ~0. ~1 V more clamp (9.2→10.3 V), still < DRV8833 VM abs-max 11.8 V. Identical DO-214AA footprint → drop-in, no layout change.
Done (PR #218):
DESIGN-NOTES.mdprotection section + BOM: D2 SMBJ5.0A/C113974 → SMBJ6.0A/C140903.Still open on this board:
12 V TVS (D1 SMBJ12A) unchanged.
docs(pcb): fix stale shunt ref in PDU notes (C53115028 -> C346481)
mottihoresh commentedon Jul 6, 2026
5V TVS supplier part locked: LCSC C5331096 (MSKSEMI SMBJ6.0A) — supersedes the placeholder C140903.
docs(pcb): 5V TVS LCSC -> C5331096 (MSKSEMI SMBJ6.0A)
docs(hardware): input-rail TVS fleet standard (SMBJ12A/SMBJ5.0A) (#218)
feat(firmware): node-health HEALTH_n frame + internal die-temperature…
[-]feat(pcb): power distribution + monitoring CAN node (segmentable injection, INA219 telemetry)[/-][+]feat(pcb): per-console power distribution + monitoring CAN node (PDU) — INA180 telemetry[/+]feat(pcb): base boards Rev 2 — PanelGroup ShiftBus remap + Gateway/PD…
fix(nodes): dependable cockpit membership — mapping file v4, offline-…