21 changes: 21 additions & 0 deletions docs/src/model/model.md
Original file line number Diff line number Diff line change
Expand Up @@ -18,6 +18,27 @@ E(t, \mathbf{r}_\perp, z) = \int_{-\infty}^{\infty} \mathrm{d}\omega \mathcal{T
```
where ``\mathcal{T}_\perp^{-1}`` is simply the inverse of ``\mathcal{T}_\perp`` so transforms from transverse reciprocal space to real space. The chief difference between variations of the UPPE implemented in `Luna` is the definition of ``\mathbf{k}_\perp`` and ``\mathcal{T}_\perp``, that is, the choice of [Modal decompositions](@ref) of the field.

## Absorbing boundaries

Both the frequency and the time axes are finite and periodic (they are sampled for FFTs), so energy which reaches the edge of either window does not leave the simulation — it wraps around, and the result is wrong. `Luna` therefore applies absorbing boundaries at the edges of both windows. These matter whenever the spectrum or the pulse genuinely reaches the edge of the grid: soliton self-compression, modulation instability, or a dispersive wave walking out of the time window.

The absorbers are defined by an absorption **coefficient per unit propagation distance** ``\alpha``, so that propagating a distance ``L`` attenuates by a fixed factor no matter how the solver subdivides that distance. As everywhere else in `Luna`, ``\alpha`` is a *power* coefficient: the power falls as ``\mathrm{e}^{-\alpha L}``, the field as ``\mathrm{e}^{-\alpha L/2}``, and a linear operator carries ``-\alpha/2``. The coefficient is derived from the apodisation profiles ``W`` built by [`Grid`](@ref Grid) as
```math
\alpha(x) = -\frac{2\log W(x)}{\ell}\,,
```
where the reference length ``\ell`` is the distance over which the historical profile is applied to the field exactly once, i.e. ``\mathrm{e}^{-\alpha\ell/2} = W``. By default ``\ell = z_\mathrm{max}/N`` with ``N`` set by `boundary_N`, i.e. the profile is applied ``N`` times over the whole propagation.

Because the adaptive stepper has to resolve ``\ell`` for the absorber to behave itself, `Luna.run` reduces `max_dz` to ``\ell`` if it is larger, and says so in the log. In practice this changes nothing — it asks for at least ``N`` steps over the propagation, and real runs take far more.

The spectral absorber is diagonal in ``\omega``, so it is simply an imaginary part of ``k(\omega)`` and is added to the linear operator ``\mathcal{L}``. The interaction-picture propagator then applies it *exactly*, over whatever sub-interval the adaptive stepper chooses, at no extra cost. The temporal absorber is diagonal in ``t`` and so cannot ride the propagator; it is applied as a factor ``\mathrm{e}^{-\alpha(t)\Delta z/2}`` to the field after each accepted step. Because these factors telescope, the total absorption over a distance is again independent of the step layout.

!!! note "Change in behaviour"
Before this scheme was introduced, the absorbing boundaries were applied by multiplying the solution by the fixed profile ``W`` once per accepted step. The cumulative absorption was then ``W^N`` with ``N`` the number of steps — a number the adaptive controller derives from `rtol`. The consequence was that the solution depended on the tolerance: tightening `rtol` increased the absorption. Nor does tightening it recover the intended taper — at typical step counts ``W^N`` is a brick wall at the edge of the flat region rather than a taper, and that brick wall is the limit the old scheme approaches. It is what eroded genuine spectral wings. Results from that scheme can be reproduced with `boundary=:legacy`, and the absorbers can be switched off entirely with `boundary=:none`. See [`Luna.run`](@ref) and [`Boundaries`](@ref Boundaries.Boundaries).

Because an absorbing boundary is doing its job silently, `Luna.run` also reports when it starts to matter: the temporal absorber keeps a running total of what it removes, and warns once if that exceeds a thousandth of the pulse. That is a measurement of what was actually absorbed rather than a prediction from the dispersion — on a grid running to several microns the largest group delays belong to the band edges, which carry nothing but shot noise, so a prediction would warn on almost every run. Seeing the warning means light is genuinely reaching the edge of the time window; if that is not intended, widen `trange`.

Note that this is separate from the band-limiting of the nonlinear polarisation which happens inside [`NonlinearRHS`](@ref NonlinearRHS): that is part of the definition of the equation being solved, and is applied to ``P_\mathrm{nl}`` rather than to the field.

## A note on sign conventions
In optics, a plane wave is usually written as
```math
Expand Down
4 changes: 4 additions & 0 deletions docs/src/modules/Boundaries.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,4 @@
# Boundaries.jl
```@autodocs
Modules = [Boundaries]
```
8 changes: 8 additions & 0 deletions docs/src/modules/Luna.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,8 @@
# Luna.jl

The top-level module. [`Luna.run`](@ref) is the low-level entry point which drives the
propagation; most users will go through [The simple interface](../interface.md) instead.

```@docs
Luna.run
```
Loading
Loading