Skip to content

SI-prefixed display for Statistics panel and chart y-axis - #9

Merged
Fyfar merged 1 commit into
mainfrom
feat/si-unit-display
Sep 28, 2026
Merged

Fyfar merged 1 commit into
mainfrom
feat/si-unit-display

Conversation

@Fyfar

@Fyfar Fyfar commented Sep 28, 2026

Copy link
Copy Markdown
Owner

Summary

Statistics panel entries (Average/Min/Max/Peak-to-Peak/Std Dev) and the realtime chart's y-axis now render with SI unit prefixes (e.g. 11.13 MΩ) instead of raw base-unit numbers (e.g. 11130000.00 Ω). Display only — no change to stored values, resolution, CSV export, or Data Log rows.

  • Each Statistics panel entry picks its own SI prefix from its own magnitude; the chart's y-axis picks one shared prefix per redraw from the visible range (lib/si.ts: siPrefixOf, formatSiValue).
  • Decimals come from the existing measurement-resolution tracking (binWidth/recordedResolution), never a new precision source.
  • The SI prefix is chosen from a value's true, unrounded magnitude and never re-picked after rounding, so a value can't be promoted into the next prefix by rounding (999999.6 Ω at 1 Ω resolution reads 1000.000 kΩ, never 1.00 MΩ).
  • Capacitance's internal base unit is nF, not physical F — corrected via toPhysicalUnit wherever a capacitance number reaches the formatter.
  • siPrefixOf relocated from lib/passfail.ts to a new lib/si.ts, now shared by the Dashboard, Pass/Fail, and the chart.

Hardware testing

Tested against a ZOYI ZT703s (28/29 cases passing on first run); three real issues found and fixed:

  • A genuine zero (e.g. Peak-to-Peak before a 2nd sample) briefly rendered as a long decimal string (0.00000000000000F) instead of 0.
  • Pass/Fail's Measured Spread panel showed a flat 3 decimals against the meter's real resolution once SI-scaled next to the Dashboard's resolution-accurate numbers. VerdictRow now carries the capturing reading's resolution; Pass/Fail tracks the coarsest resolution across the batch's captured rows, same as the Dashboard.
  • Clear Batch could re-trigger a capture (and verdict beep) for a part still sitting on the probes, from any view, because it redundantly reset the same-part capture guard that already re-arms correctly on a genuine probe lift.

Three unrelated findings from the same test pass (unbounded manual y-range inputs, unscaled histogram bin labels, a bad x-axis offset after reload-before-reconnect) are recorded as known issues, not fixed here.

Verification

  • npx tsc --noEmit — clean
  • npx eslint — clean
  • npm run check — all 8 self-checks pass, including new check-si.mts (19/19)
  • npm run build — production build succeeds
  • Two independent cold code reviews of the full diff (must-fix: none)
  • Manual hardware verification against a real ZT703s

Version bumped 1.7.2 → 1.8.0 (minor, non-breaking addition).

🤖 Generated with Claude Code

Statistics panel entries (Average/Min/Max/Peak-to-Peak/Std Dev) and the
realtime chart's y-axis now render with SI unit prefixes (e.g. "11.13 MΩ")
instead of raw base-unit numbers (e.g. "11130000.00 Ω"). Display only —
no change to stored values, resolution, CSV export, or Data Log rows.

- Each Statistics panel entry picks its own SI prefix from its own
  magnitude; the chart's y-axis picks one shared prefix per redraw from
  the visible range (lib/si.ts: siPrefixOf, formatSiValue).
- Decimals come from the existing measurement-resolution tracking
  (binWidth/recordedResolution), never a new precision source.
- The SI prefix is chosen from a value's true, unrounded magnitude and
  never re-picked after rounding, so a value can't be promoted into the
  next prefix by rounding (999999.6 Ω at 1 Ω resolution reads
  "1000.000 kΩ", never "1.00 MΩ").
- Capacitance's internal base unit is nF, not physical F — corrected via
  toPhysicalUnit wherever a capacitance number reaches the formatter.
- siPrefixOf relocated from lib/passfail.ts to a new lib/si.ts, now
  shared by the Dashboard, Pass/Fail, and the chart.

Hardware-tested against a ZOYI ZT703s (28/29 cases passing on first run);
three real issues found and fixed:
- A genuine zero (e.g. Peak-to-Peak before a 2nd sample) briefly rendered
  as a long decimal string ("0.00000000000000F") instead of "0".
- Pass/Fail's Measured Spread panel showed a flat 3 decimals against the
  meter's real resolution once SI-scaled next to the Dashboard's
  resolution-accurate numbers. VerdictRow now carries the capturing
  reading's resolution; Pass/Fail tracks the coarsest resolution across
  the batch's captured rows, same as the Dashboard.
- Clear Batch could re-trigger a capture (and verdict beep) for a part
  still sitting on the probes, from any view, because it redundantly
  reset the same-part capture guard that already re-arms correctly on a
  genuine probe lift.

Three unrelated findings from the same test pass (unbounded manual
y-range inputs, unscaled histogram bin labels, a bad x-axis offset after
reload-before-reconnect) are recorded as known issues, not fixed here.

🤖 Generated with [Claude Code](https://claude.ai/code)
@Fyfar
Fyfar force-pushed the feat/si-unit-display branch from 19c9f67 to 3b95c0b Compare September 28, 2026 12:40
@Fyfar
Fyfar merged commit fc6ee6b into main Sep 28, 2026