Daemon ownership runtime

Milestone 19.3 introduces the renderer-neutral DaemonRuntime ownership foundation. It coordinates one scanner control session, continuous PSI, one SDS200 RTSP/RTP audio session, one decoded-PCM fanout, and dynamic PCM destinations.

Milestone 19.4 adds DaemonSignalController, DaemonProcess, and the foreground sdsctl daemon command. The process host owns signal installation, waits for a shutdown request, stops the runtime deterministically, and restores the previous signal handlers before returning.

Milestone 19.5 adds a private Unix-domain socket, a strict versioned JSON Lines protocol, and bounded read-only access to daemon capabilities and authoritative runtime snapshots.

Milestone 19.6 adds a second private Unix-domain socket for ordered daemon events. Every event subscription starts with an authoritative runtime snapshot and then receives later runtime, scanner, PSI, radio-state, audio-lifecycle, and destination-health events.

Milestone 19.7 adds a third private Unix-domain socket for accepted RTP PCMU packets. Each client owns an independent bounded queue, receives the original payload before decode, and observes RTP continuity plus cumulative local queue loss.

Milestone 19.8 adds capability-checked daemon operations for hold, next, previous, and bounded reconnect. Mutations are single-owner, concurrent requests are rejected rather than queued, completion follows scanner acknowledgement, and successful responses include authoritative runtime snapshots. Reconnect is limited to the directly owned SDS200 UDP control transport.

Milestone 19.9 adds explicit CLI daemon-client status, authoritative snapshot, safe-control, ordered event-watch, and PCMU playback or WAV-recording workflows while preserving the standalone top-level scanner and direct-audio commands. Milestone 19.10 adds explicit daemon-backed TUI operation using the API, event, and PCMU services while preserving standalone TUI ownership as the default. Milestone 19.11 adds validated saved-destination activation and transactional SIGHUP replacement. Milestone 20.5 adds a daemon-owned recording manager over the shared decoded-PCM router plus a fourth private Unix-domain socket for bounded finalized-recording access. Milestone 20.6 adds default-on semantic PSI silence detection and bounded recovery inside the foreground ownership loop. Milestone 20.8 adds an optional daemon-owned MQTT publication worker over the existing authoritative event stream. It publishes semantic state without opening scanner hardware, skips packet-rate PSI events, and isolates broker retry/backoff from scanner, PSI, audio, recording, and local-service ownership. Milestone 20.9 adds explicitly opt-in MQTT scanner controls through the same semantic daemon API dispatcher used by local clients, without adding another scanner owner. Milestone 20.10 adds optional Home Assistant MQTT device discovery over those existing semantic topics, including birth-triggered republication, without adding another scanner owner. Milestone 20.12.3 adds seven dedicated Home Assistant control topics that translate four desired-state Hold switches plus Previous Channel, Next Channel, and Reconnect Scanner into fresh typed daemon-control requests. The worker derives navigation only from ordered daemon-owned radio state and clears that context after scanner disconnect or event-sequence resynchronization. The Home Assistant App keeps the independent generic MQTT request-envelope command input disabled. No Home Assistant path opens scanner hardware directly. Decoded-PCM CLI subscriptions and automatic daemon discovery and selection remain follow-on work. The process does not fork or create a pidfile.

Foreground process contract

Start the process with an explicit SDS200 network host:

sdsctl --log-level INFO --host 192.168.0.251 daemon

A saved network or fallback profile is also accepted:

sdsctl --log-level INFO --profile home daemon

The command constructs exactly one DaemonRuntime, one PcmSinkRouter, one NetworkAudioTransport, one compatibility-named DaemonReadOnlyApi, one bounded DaemonApiServer, one DaemonEventStream, one bounded DaemonEventServer, one PcmuStream, one bounded DaemonPcmuServer, one DaemonRecordingManager, one bounded DaemonRecordingFileServer, one DaemonDestinationCoordinator, and one DaemonDestinationReloader. When a daemon MQTT manifest is present, construction also creates one DaemonMqttWorker using the existing DaemonEventStream; an absent manifest creates no MQTT worker and does not require Paho MQTT. The process constructs one DaemonReadOnlyApi instance and shares it with both DaemonApiServer and the MQTT worker, so enabled MQTT commands reuse the exact local semantic-control boundary. The API class retains its historical public name while exposing backward-compatible reads, explicit safe controls, and daemon recording operations. The PCMU stream subscribes to the same authoritative transport used by the decoded-PCM fanout. The coordinator activates the validated startup destination set against the shared decoded-PCM router, while the recording manager attaches and detaches its WAV sink from that same router. Daemon-client audio continues to consume PCMU independently. Decoded-PCM client subscriptions remain follow-on work.

The audio endpoint must come from either --host or a network-capable SDS200 profile. A fallback profile may select serial control at runtime, but its saved network host still supplies the RTSP/RTP audio endpoint. Serial-only profiles, bare serial selection, replay captures, and non-SDS200 network-audio selections are rejected.

The command runs in the foreground. It does not daemonize itself, fork, create a pidfile, change privileges, install a service unit, or request socket activation. The event and PCMU services own their sockets before runtime startup so the event stream can observe lifecycle transitions and PCMU clients can subscribe before authoritative audio begins. The finalized-recording service opens after runtime and destination activation, and the request-response API opens last so recording operations are not admitted before all required local services exist.

Signals and exit behavior

DaemonSignalController installs stop handlers for SIGINT and SIGTERM and, where available, a reload handler for SIGHUP. Stop handlers record the terminating signal and wake the normal process loop. SIGHUP records a pending destination reload without requesting shutdown. No runtime or destination work occurs inside a signal handler.

Previous signal handlers are restored after the process loop exits. Partial signal-installation failures roll back handlers that were already replaced. Restoration attempts continue after an individual restoration failure.

A controlled SIGINT or SIGTERM shutdown returns success after the runtime stops. Startup, configuration, transport, or shutdown failures produce the normal sdsctl error path. When process work and cleanup both fail, the primary process failure remains authoritative and the cleanup failure is logged by type without exposing its message.

SIGHUP reloads the same destination manifest selected during daemon startup. The manifest is loaded and validated before the coordinator transaction begins. Loader and activation failures are logged by exception type and leave the previous committed destination set running. Post-commit cleanup failures are reported without rolling back the successfully activated replacement. A stop request takes priority over a pending reload.

Local service process lifecycle

At the process-host level, startup occurs in this order:

  1. bind and start the local DaemonEventServer;
  2. bind and start the local DaemonPcmuServer;
  3. start DaemonRuntime;
  4. start the optional daemon MQTT worker;
  5. activate the validated daemon destination configuration;
  6. bind and start the local DaemonRecordingFileServer;
  7. bind and start the local DaemonApiServer; and
  8. wait for SIGHUP, SIGINT, SIGTERM, or another process-loop failure.

Starting the event service first allows an already connected client to observe runtime startup transitions. Starting the PCMU service before the runtime allows clients to subscribe before the shared transport begins publishing accepted packets. MQTT starts only after the runtime is authoritative, so its first broker session can publish a running snapshot and, when enabled, Home Assistant device Discovery, but before destinations so it can observe their later health. Broker connectivity and Home Assistant birth-topic handling stay inside the MQTT worker and do not make scanner ownership depend on broker or Home Assistant availability. Starting the recording-file service after runtime and destination activation makes finalized inventory access available before recording API requests are admitted. Starting the API last ensures every admitted request observes an initialized runtime and configured recording service.

Shutdown occurs in this order:

  1. close the API listener and connected request-response clients;
  2. wait for bounded API worker completion;
  3. close the recording-file listener and connected finalized-file readers;
  4. wait for bounded recording-file worker completion;
  5. close the daemon recording manager, finalizing an active recording when possible;
  6. stop all configured daemon-owned destinations;
  7. publish retained MQTT offline when possible and stop the optional MQTT worker;
  8. stop the daemon runtime while the event service remains available for final lifecycle transitions;
  9. close the PCMU listener, publisher subscription, and connected clients;
  10. wait for bounded PCMU worker completion;
  11. close the event listener and connected subscribers; and
  12. wait for bounded event-worker completion.

If any component startup fails, cleanup is attempted for every component whose startup was attempted. Cleanup continues after an individual failure, while the primary startup or process error remains authoritative. The MQTT worker is stopped before runtime cleanup so a session that reached retained online can attempt retained offline; unexpected broker loss instead relies on its retained offline last will. See the daemon MQTT guide, local daemon API guide, and local daemon event stream guide for their publication, socket, framing, permission, limit, and failure-isolation contracts.

Ownership graph

One runtime owns:

  1. one SDSScanner control connection;
  2. one active PSI scanner-information stream;
  3. one AudioFanoutSession;
  4. one PcmSinkRouter included in that fanout; and
  5. any playback, recording, streaming, or integration sinks attached to the router.

After acquiring the scanner connection, the runtime probes model and firmware once before starting PSI. Each probe is bounded by the scanner command timeout and is independently nonfatal. Authoritative snapshots retain successful values and serialize a failed or empty probe as null, without surrendering scanner ownership or interrupting PSI and audio startup.

The scanner's PCMU audio is accepted once. Each accepted packet is first published to the bounded PCMU stream with its original payload and RTP continuity metadata, then decoded once and submitted to the router as 8 kHz mono signed 16-bit PCM. Each attached sink retains its existing bounded buffering, worker, health, and failure-isolation behavior.

A destination failure does not stop scanner control, PSI, RTP reception, or another healthy destination.

Lifecycle

Startup is serialized in ownership order:

  1. connect scanner control;
  2. start PSI and wait for its initial response;
  3. start the audio fanout, which starts the PCM router before opening the audio transport; and
  4. publish the running runtime transition.

Shutdown proceeds in reverse ownership order:

  1. stop the audio fanout and router destinations;
  2. stop PSI;
  3. close scanner control; and
  4. publish either stopped or failed.

A failed startup performs best-effort reverse-order cleanup for every component whose startup was attempted. Cleanup continues after an individual cleanup failure so later owners are still released.

stop() is idempotent and serialized across concurrent callers. A successfully stopped or failed runtime cannot be restarted; callers must construct a new runtime instance.

PSI silence recovery

The foreground process calls DaemonRuntime.poll() from its existing bounded process loop; recovery does not add another watchdog thread. DaemonRuntime subscribes to scanner.on_psi() and records a monotonic timestamp for every successfully parsed PSI frame, including frames whose radio-state fields did not change. This makes the watchdog a semantic PSI-liveness check rather than a generic UDP receive timer.

Automatic recovery is enabled by default. The daemon waits 10 seconds after the most recent PSI observation before attempting recovery and applies a 60-second cooldown after a completed recovery attempt. The command-line policy is:

--psi-auto-recover / --no-psi-auto-recover
--psi-recover-after SECONDS
--psi-recovery-cooldown SECONDS

A stale stream is recovered with the existing bounded reconnect(timeout=2.0) path, so directly owned SDS200 UDP control transports reopen and restore their configured PSI interval. Automatic recovery shares the same nonblocking mutation lock used by API, TUI-daemon-client, and browser scanner controls. If another mutation owns that slot, poll() simply defers recovery and does not consume the cooldown; the next process-loop poll may retry once the control completes.

Recovery failures are isolated from the daemon process, logged by exception type, and rate-limited by the same cooldown. The RTSP/RTP audio transport is independent from scanner control/PSI, so a control-transport reconnect does not intentionally stop daemon-owned audio.

Daemon-owned scanner controls

DaemonRuntime exposes typed compatibility hold(), semantic hold_state(), next(), previous(), and reconnect() methods for the local API. It does not expose raw scanner command strings or a generic key operation.

Every control:

  • requires a running runtime;
  • requires a connected scanner for navigation operations;
  • validates a positive finite caller deadline;
  • acquires one nonblocking mutation slot;
  • executes under runtime lifecycle ownership;
  • waits for authoritative scanner completion; and
  • returns an immutable DaemonControlResult containing sequence, operation, start and completion timestamps, and the completion snapshot.

A second mutation arriving while one is active raises DaemonControlBusyError. It is not queued, so separate clients cannot build an unbounded mutation backlog or interleave scanner command sequences.

Navigation completion requires the scanner's matching OK acknowledgement. Explicit NG, ERR, or ERROR responses are classified as scanner rejection. Timeout and transport failures remain redacted at the daemon API boundary.

hold_state(scope, held) is a separate desired-state contract rather than a reinterpretation of indexed hold(). It accepts system, department, site, or channel, reads authoritative GSI before deciding whether any key gesture is necessary, and no-ops when the requested On/Off state already matches. Enabling a hold requires a real current selection index; the SDS200 unsigned-32 maximum sentinel is rejected. Releasing an already held scope does not require that cached selection to remain available.

The physically verified SDS200 gestures are one KEY,A,P for System Hold, one KEY,B,P for Department Hold, KEY,F,P followed by KEY,B,P for Site Hold, and one KEY,C,P for Channel Hold. Every key in a gesture and all authoritative completion reads execute inside one daemon mutation. Completion is not inferred from the key acknowledgement: the runtime polls GSI until the requested hold field reaches the desired state. Site completion intentionally ignores temporary unrelated field inconsistencies observed during physical validation.

Compatibility navigation and reconnect retain their two-second control maximum. Semantic hold-state has a separate four-second maximum so the measured SDS200 GSI convergence fits inside the bounded API contract.

Daemon reconnect is available only when SDSScanner directly owns an SDS200 UdpTransport. Serial, fallback, replay, and injected transports do not advertise the bounded reconnect capability and are rejected before mutation.

There is no separate scanner.resume or unrestricted public scanner.key operation. Release is expressed idempotently as semantic scanner.hold_state(..., held=False).

Dynamic PCM destinations

A PcmSink may be attached before runtime startup or while the runtime is running:

runtime.attach_sink(playback)
runtime.attach_sink(recording)

Pre-attached destinations start with the router. A destination attached while running starts immediately. A failed destination start is recorded by PcmSinkRouter and detached without stopping the runtime.

Detach a destination independently:

runtime.detach_sink(recording)

The default stop=True waits for any in-flight PCM submission and then stops the destination. Passing stop=False only detaches it from future submissions.

No sink may be attached after the runtime reaches a terminal state.

Snapshots and transitions

DaemonRuntime.snapshot() returns an immutable DaemonRuntimeSnapshot containing:

  • runtime lifecycle state;
  • scanner endpoint and connection state;
  • configured PSI interval and current PSI state;
  • the latest immutable RadioStateSnapshot;
  • audio packet, sample, endpoint, and sink statistics;
  • the complete PcmSinkRouterSnapshot;
  • lifecycle timestamps and transition sequence; and
  • a redacted last-failure type.

DaemonRuntimeSnapshot.as_dict() returns JSON-compatible renderer-neutral data.

Subscribe to ordered lifecycle changes with:

unsubscribe = runtime.on_transition(handle_transition)

Each DaemonRuntimeTransition includes its sequence, aware UTC observation timestamp, previous state, new state, and the snapshot captured at that transition. Listener exceptions are isolated by the shared event bus.

Runtime states are:

  • idle
  • starting
  • running
  • stopping
  • stopped
  • failed

Python example

from sds200 import (
    AudioFanoutSession,
    AudioStream,
    DaemonRuntime,
    NetworkAudioTransport,
    PcmSinkRouter,
    SDSScanner,
)

host = "192.168.0.251"

scanner = SDSScanner.network(host)
router = PcmSinkRouter(name="daemon-pcm")
audio = AudioFanoutSession(
    AudioStream(NetworkAudioTransport(host)),
    (router,),
)
runtime = DaemonRuntime(scanner, audio, router)

runtime.attach_sink(playback_sink)

with runtime:
    run_application()

Application code is responsible for constructing concrete destinations and deciding how long the runtime remains active.

Physical SDS200 validation

Validated on 2026-08-04 with a physical SDS200 network endpoint:

  • foreground startup opened scanner control, completed the initial PSI response, and started the RTSP/RTP decoded-PCM fanout;
  • Ctrl+C produced a controlled SIGINT shutdown with reverse-order cleanup and exit status 0;
  • an externally delivered SIGTERM, matching the documented systemd contract, produced reverse-order cleanup and exit status 0; and
  • both runs received live scanner audio before shutdown.

The Milestone 19.5 local API layer was also validated on 2026-08-04 against the same physical SDS200:

  • the managed socket directory and socket used modes 0700 and 0600;
  • all six read-only protocol operations returned correlated successful responses while scanner control, PSI, audio, and the router were live;
  • malformed JSON was isolated and the same client connection remained usable;
  • an independent second client completed a capability request;
  • the runtime received seven RTP packets and 2,240 decoded samples; and
  • SIGTERM returned exit status 0 after closing clients and removed the owned socket before process exit.

The Milestone 19.6 events.sock service was physically validated on 2026-08-05 against the same SDS200:

  • the caller-managed validation directory used mode 0700, and both daemon.sock and events.sock used mode 0600;
  • two independent event clients received authoritative stream.snapshot envelopes at sequence 11, while a third connection above the configured limit was closed without receiving an event;
  • the existing request-response API completed a correlated ping while both event clients remained connected;
  • the primary client received 76 valid events from sequence 11 through 86 with no gaps, regressions, malformed lines, or reader errors;
  • live traffic produced 38 scanner.psi and 34 radio.state events;
  • controlled SIGTERM delivered final audio.state, scanner.connection, and daemon.transition events while the event service remained active;
  • the runtime received 507 RTP packets and 162,240 decoded samples; and
  • the process returned exit status 0 and removed both owned sockets.

The Milestone 19.7 pcmu.sock service was physically validated on 2026-08-05 against the same SDS200:

  • the caller-managed validation directory used mode 0700, and all three local sockets used mode 0600;
  • one API client completed 61 successful pings while one event client and two PCMU clients remained connected;
  • the event client received 231 ordered messages from sequence 1 through 231 without a gap;
  • both PCMU clients received the same 1,503 frames and 480,960 payload bytes without queue loss, overflow, stream gaps, RTP discontinuity, timestamp reversal, or mismatched overlapping frames;
  • a third PCMU connection above the configured limit was rejected;
  • decoded audio advanced by 1,500 packets and 480,000 samples during the 60-second simultaneous-client interval; and
  • controlled SIGTERM returned exit status 0 and removed daemon.sock, events.sock, and pcmu.sock.

Milestone 19.11 destination activation and reload were physically validated on 2026-08-06 against the same SDS200:

  • startup activated an initial recording destination;
  • SIGHUP transactionally replaced it with recording plus audible playback;
  • an invalid version 2 manifest failed with ConfigurationError while the committed destinations and daemon runtime continued;
  • a valid empty manifest removed all active destinations;
  • finalized recordings remained valid 8 kHz mono signed 16-bit WAV files; and
  • controlled SIGTERM returned exit status 0 and removed all three sockets.

Milestone 19.8 safe-control contracts are covered by hardware-independent tests, including acknowledgements, rejection, deadlines, unsupported transports, concurrent requests, shutdown interaction, and unchanged read-only operations.

Milestone 20.6 semantic hold-state control was physically validated on 2026-08-08 against SDS200 firmware 1.26.01. Single A, B, and C key presses toggled System, Department, and Channel Hold in both directions; F followed by B toggled Site Hold in both directions without changing Department Hold. Measured authoritative GSI convergence after acknowledgement ranged from 0.115 seconds for Channel release to 2.519 seconds for Site activation. Those measurements include scanner reporting and polling behavior and are not claimed as physical switch latency.

The complete safe-control sequence was physically validated on 2026-08-05 against the same SDS200:

  • capability negotiation advertised hold, next, previous, and reconnect with the documented two-second maximum deadline;
  • TGID hold, next, previous, hold release, and bounded reconnect completed with increasing control sequences and healthy authoritative runtime snapshots;
  • the validator bound navigation to the PSI-reported held selection so normal scanning movement between the precondition snapshot and hold acknowledgement did not make restoration ambiguous;
  • hold returned to Off, reconnect produced both connection transitions, and API, event, PSI, RTSP/RTP, decoded-audio, and PCMU activity remained healthy;
  • two PCMU clients received 410 identical loss-free frames each while the event client received 82 ordered messages without a gap; and
  • controlled SIGTERM returned exit status 0 and removed all three local sockets.

CLI daemon audio client validation

A separate 2026-08-05 physical run exercised sdsctl daemon-client audio through the private PCMU socket with simultaneous default-device playback and WAV recording. The client received 258 consecutive frames from sequence 16 through 273 and 82,560 samples without PCMU stream gaps, daemon queue loss, RTP loss, missing samples, or timestamp reversal. The WAV finalized as 8 kHz mono signed 16-bit PCM with a duration of 10.320 seconds. The independent bounded playback queue wrote 159,942 bytes and reported six overflows dropping 2,088 PCM bytes without underflow. API health remained authoritative after the client exited, and controlled SIGTERM removed all three sockets with exit status 0.

Daemon-backed TUI validation

A physical SDS200 run on August 5, 2026, exercised sdsctl tui --daemon-client through explicit API, event, and PCMU sockets. The TUI rendered cleanly, followed live scanner state, completed a safe control, automatically started playback, toggled playback with A, and finalized a 53.120-second 8 kHz mono WAV plus metadata. Quitting the TUI left the original daemon process, scanner connection, PSI, RTSP/RTP audio, and decoded-PCM router running. Controlled SIGTERM subsequently removed all three sockets.

Daemon PSI silence recovery validation

Milestone 20.6 PSI recovery was physically validated against SDS200 firmware 1.26.01 by dropping only inbound UDP packets from scanner port 50536 to the daemon's current local scanner-control port. The rule dropped 19 datagrams while leaving the separate audio socket untouched.

The running daemon detected 10.1 seconds without a parsed PSI frame, logged one stale-stream warning, executed its bounded reconnect, and reopened scanner control on a new local UDP port. Ordered scanner.psi events resumed immediately and continued with live state changes. The daemon PID remained unchanged, the web process stayed running, and daemon audio advanced from 3,997 to 4,495 accepted RTP packets across the test. This validates recovery from silent PSI without opening a second scanner controller or intentionally interrupting the independent audio path.

Follow-on work

Later work may:

  • add bounded decoded-PCM subscriptions for local clients;
  • add daemon discovery and automatic client selection; and
  • add decoded-PCM CLI client workflows.

Decoded-PCM subscription, discovery, and automatic selection remain follow-on work. Saved destination activation and validated SIGHUP replacement are part of the current daemon contract.

See Daemon deployment and upgrade guide for service installation, explicit socket paths, destination manifests, reload, migration, and upgrade procedures.