linear humidity coefficients out of date for newer sensors ( after 2008 ? ) #7

Description

@cenau

Sensors after v3 use a new set of more 'optimised' coefficients. The lib only uses the old ones.

New coefficients

C1 = -2.0468;
C2 = 0.0367;
C3 = -0.0000015955;

relevant lines 82 to 84 in SHT1x.cpp

Most recent datasheet
http://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/Humidity/Sensirion_Humidity_SHT1x_Datasheet_V5.pdf

Older datasheet explaining the change
http://courses.cs.tau.ac.il/embedded/docs/TelosB/SHT11.pdf