Summary

This page documents the GregTech and TecTech integrations exposed through OpenComputers and Computronics. The available components cover general machine state, battery buffers, digital chests, circuit-configurable machines, device sensor information, and TecTech multiblock parameters.

Availability

  • Dependency: gregtech
  • Label: integration-required

Component Names

  • gt_machine
  • gt_batterybuffer
  • digital_chest
  • tt_machine
  • bec_diode
  • bec_io_node
  • bec_storage

What This Integration Is Good For

  • Reading stored EU and steam from GregTech machine tiles.
  • Monitoring work progress, active state, and owner data.
  • Querying or changing integrated-circuit settings on supported machines.
  • Inspecting batteries in battery buffers.
  • Reading digital chest contents and TecTech parameter groups.

Components

gt_machine

gt_machine is a shared component name used by several different GregTech drivers. A particular machine may expose only part of the API below, depending on which driver matched it.

BaseMetaTileEntity-backed methods

These callbacks come from the BaseMetaTileEntity driver and are available when the target is a GregTech base meta tile.

getEUStored()
  • Syntax: getEUStored(): number
  • Purpose: Return the EU currently stored in the block.
getSteamStored()
  • Syntax: getSteamStored(): number
  • Purpose: Return the steam currently stored in the block.
getEUMaxStored()
  • Syntax: getEUMaxStored(): number
  • Purpose: Return the maximum EU capacity of the block.
getSteamMaxStored()
  • Syntax: getSteamMaxStored(): number
  • Purpose: Return the maximum steam capacity of the block.
getEUInputAverage()
  • Syntax: getEUInputAverage(): number
  • Purpose: Return the block's average EU input.
getEUOutputAverage()
  • Syntax: getEUOutputAverage(): number
  • Purpose: Return the block's average EU output.
getOwnerName()
  • Syntax: getOwnerName(): string
  • Purpose: Return the owner name recorded by the block.

IMachineProgress-backed methods

These callbacks come from the IMachineProgress driver and are available on GregTech machines exposing work-progress data.

hasWork()
  • Syntax: hasWork(): boolean
  • Purpose: Return whether the machine currently has work to do.
getWorkProgress()
  • Syntax: getWorkProgress(): number
  • Purpose: Return the machine's current progress value.
getWorkMaxProgress()
  • Syntax: getWorkMaxProgress(): number
  • Purpose: Return the maximum progress value for the current work cycle.
isWorkAllowed()
  • Syntax: isWorkAllowed(): boolean
  • Purpose: Return whether the machine is currently allowed to work.
setWorkAllowed(work)
  • Syntax: setWorkAllowed(work: boolean)
  • Purpose: Enable or disable machine work permission.
  • Parameters:
    • work: true to enable working, false to disable it.
  • Returns:
    • No useful return value on success.
  • Usage notes:
    • The driver only changes state when exactly one boolean argument is supplied.
isMachineActive()
  • Syntax: isMachineActive(): boolean
  • Purpose: Return whether the machine is currently active.
getCoordinates()
  • Syntax: getCoordinates(): number, number, number
  • Purpose: Return the machine coordinates.
  • Returns:
    • x, y, z when the Computronics GregTech coordinate option is enabled.
    • An empty return list when that option is disabled.
getName()
  • Syntax: getName(): string
  • Purpose: Return the GregTech meta-tile name.

Device information method

This callback comes from the IGregTechDeviceInformation driver and is only exposed when the tile reports that it is currently giving information.

getSensorInformation()
  • Syntax: getSensorInformation(): table
  • Purpose: Return the GregTech info text lines for the machine.
  • Returns:
    • The array returned by getInfoData().

Circuit-configuration methods

These callbacks are exposed when the machine implements IConfigurationCircuitSupport.

getCircuitConfiguration()
  • Syntax: getCircuitConfiguration(): number | nil, string?
  • Purpose: Return the installed integrated-circuit configuration.
  • Returns:
    • A configuration number when a valid integrated circuit is installed.
    • -1 when the circuit slot is valid but currently empty or contains a non-circuit item.
    • nil, "Machine does not support circuit configuration." when the machine does not support this feature.
    • nil, "Invalid circuit slot index." when the reported circuit slot is outside the inventory range.
setCircuitConfiguration(config)
  • Syntax: setCircuitConfiguration(config: number): boolean | nil, string
  • Purpose: Install, replace, or remove an integrated circuit.
  • Parameters:
    • config: 1 through 24 to install a circuit with that setting, or -1 to remove the installed circuit.
  • Returns:
    • true on success.
    • nil, "Machine does not support circuit configuration." when unsupported.
    • nil, "Invalid circuit slot index." when the reported slot is invalid.
    • nil, "Invalid circuit configuration value: ..." when the value is outside 1..24 and not -1.

gt_batterybuffer

gt_batterybuffer is exposed on GregTech basic battery buffers.

getBatteryCharge(slot)

  • Syntax: getBatteryCharge(slot: number): number | nil, string?
  • Purpose: Return the EU currently stored in the battery located in the specified slot.
  • Parameters:
    • slot: one-based slot index.
  • Returns:
    • The current charge for an electric item.
    • nil, "slot does not exist" when the slot index is out of range.
    • nil, "slot is empty" when the slot is empty.
    • nil, "item in slot is not electric" when the item is not recognized as an electric item.

getMaxBatteryCharge(slot)

  • Syntax: getMaxBatteryCharge(slot: number): number | nil, string?
  • Purpose: Return the maximum EU capacity of the battery located in the specified slot.
  • Parameters:
    • slot: one-based slot index.
  • Returns:
    • The maximum charge for an electric item.
    • nil, "slot does not exist" when the slot index is out of range.
    • nil, "slot is empty" when the slot is empty.
    • nil, "item in slot is not electric" when the item is not recognized as an electric item.

digital_chest

digital_chest is exposed on GregTech digital chests.

getContents()

  • Syntax: getContents(): table
  • Purpose: Return the digital chest's stored-item data table.
  • Returns:
    • The raw structure returned by getStoredItemData().
  • Usage notes:
    • This is the chest's own storage descriptor, so its field layout follows GregTech's digital-chest data format.

tt_machine

tt_machine is exposed on TecTech multiblocks derived from TTMultiblockBase.

getParameters(hatch, id)

  • Syntax: getParameters(hatch: number, id: number): number
  • Purpose: Return the current parameter value for one TecTech parameter input slot.
  • Parameters:
    • hatch: parameter group index.
    • id: parameter index within that group.

setParameters(hatch, id, value)

  • Syntax: setParameters(hatch: number, id: number, value: number)
  • Purpose: Write a new parameter value into one TecTech parameter slot.
  • Parameters:
    • hatch: parameter group index.
    • id: parameter index within that group.
    • value: new floating-point value.
  • Returns:
    • No useful return value on success.

bec_diode

bec_diode is exposed on TecTech Bose-Einstein condensate diode meta tiles.

getCondensateFilter()

  • Syntax: getCondensateFilter(): string | nil
  • Purpose: Return the fluid registry name used as the condensate filter, or nil when no filter is set.

setCondensateFilter(fluidName)

  • Syntax: setCondensateFilter(fluidName: string | nil)
  • Purpose: Set the condensate filter by fluid registry name. Passing nil clears the filter.
  • Errors:
    • Unknown fluid names raise Unknown fluid: ....

bec_io_node

bec_io_node is exposed on TecTech BEC input/output nodes.

Read-only recipe state

  • getRequiredCondensate(): table | nil: map fluid registry names to amounts required by the current recipe.
  • getConsumedCondensate(): table | nil: map fluid registry names to amounts consumed so far.
  • getProvidedTier(): table | nil: return {name, tier} for the nanite tier provided by this node.
  • getRequiredTier(): table | nil: return {name, tier} for the current recipe's required tier.
  • getAvailableNanites(): number: return available nanites.
  • getSlowdowns(): number: return the number of applied slowdowns.
  • getParallelRecipesInProgress(): number: return the number of parallel recipes in progress.
  • getMinParallel(): number: return the configured minimum parallel recipe count.
  • getMaxParallel(): number: return the configured maximum parallel recipe count.
  • getManualSlowdown(): number: return the configured manual slowdown.
  • getRecipeSteps(): table | nil: return recipe step tables with nanite, start, end, and index fields.
  • getState(): string: return idle, unpowered, assembler-offline, nanite-tier-too-low, paused-step, paused-immediate, crafting, or internal-error.

setMinParallel(min)

  • Syntax: setMinParallel(min: number)
  • Purpose: Set the minimum parallel recipe count.

setMaxParallel(max)

  • Syntax: setMaxParallel(max: number)
  • Purpose: Set the maximum parallel recipe count.

setSpeedDivisor(divisor)

  • Syntax: setSpeedDivisor(divisor: number)
  • Purpose: Set the recipe speed divisor.

Condensate tables map fluid registry names to numeric amounts. Nanite tier tables contain name and numeric tier; recipe step tables contain the nanite tier plus start, end, and index.

bec_storage

bec_storage is exposed on TecTech BEC storage nodes.

getFieldStrength()

  • Syntax: getFieldStrength(): number
  • Purpose: Return the storage node field strength.

setFieldStrength(strength)

  • Syntax: setFieldStrength(strength: number)
  • Purpose: Set the storage node field strength.

getStoredCondensate()

  • Syntax: getStoredCondensate(): table
  • Purpose: Return a table mapping fluid registry names to stored condensate amounts.

Example

local component = require("component")

if component.isAvailable("gt_machine") then
  local machine = component.gt_machine
  print("Stored EU:", machine.getEUStored())
  print("Machine active:", machine.isMachineActive and machine.isMachineActive())
end

if component.isAvailable("gt_batterybuffer") then
  local buffer = component.gt_batterybuffer
  local charge, err = buffer.getBatteryCharge(1)
  print("Slot 1:", charge or err)
end

Related

  • ic2
  • gregtech