The limit introduced in #11502 means I cannot run the BCHydro model anymore in a classical calculation.
NB: I'm running with a rupture mesh spacing of 1km which is required to replicate the BCHydro results.
I have for now circumvented by manually increasing the hardcoded limit of 27,000. Perhaps this limit could become overwritable in the openquake.cfg configle file and 27,000 is the default?

The limit introduced in #11502 means I cannot run the BCHydro model anymore in a classical calculation.
NB: I'm running with a rupture mesh spacing of 1km which is required to replicate the BCHydro results.
I have for now circumvented by manually increasing the hardcoded limit of 27,000. Perhaps this limit could become overwritable in the
openquake.cfgconfigle file and 27,000 is the default?