From 879856a3006802d97a0ec77977d46e7eb79ed9e5 Mon Sep 17 00:00:00 2001 From: Sonny Piers Date: Tue, 2 Jun 2026 15:46:10 +0200 Subject: [PATCH] Update test-suite-run template --- .github/ISSUE_TEMPLATE/test-suite-run.md | 86 ++++++++++++------------ 1 file changed, 44 insertions(+), 42 deletions(-) diff --git a/.github/ISSUE_TEMPLATE/test-suite-run.md b/.github/ISSUE_TEMPLATE/test-suite-run.md index 2f9555272..45c1c4d0c 100644 --- a/.github/ISSUE_TEMPLATE/test-suite-run.md +++ b/.github/ISSUE_TEMPLATE/test-suite-run.md @@ -10,9 +10,9 @@ assignees: "" **PlanktoScope** -- Hardware version: eg `v2.5` -- Software version: eg `2025.0.0.alpha.1` -- Machine name: eg `sponge-care-245` +- Hardware version: eg `v2.6` or `v3.0` +- Software version: eg `2026.0.0-beta.1` +- Machine name: eg `sponge-bob` - Serial number: eg `U132` (leave empty if unknown) **Computer** @@ -26,17 +26,14 @@ Anything else worth knowing? # Test suite -## Setup +(re) start the PlanktoScope -1. [Set up the SD card and start the PlanktoScope](https://docs.planktoscope.community/setup/software/standard-install/) -2. [ ] The PlanktoScope asks for Hardware version - -## Sample + @@ -44,34 +41,35 @@ Anything else worth knowing? **LED and preview** -1. [ ] "Light on" turns on the LED +1. [ ] Light "On" turns on the LED 2. [ ] The preview shows images without significant lag -3. [ ] Updating "ISO" modifies the image -4. [ ] Updating "Shutter Speed" modifies the image - -5. [ ] "Light off" turns off the LED +3. [ ] The "Calibrate" button performs a successful calibration +4. [ ] Light "Off" turns off the LED **Focus** -1. [ ] "UP 1MM" moves the focus in one direction -2. [ ] "DOWN 1MM" moves the focus in the other direction -3. [ ] Quick succession of "UP 100MM" moves the focus in one direction -4. [ ] Quick succession of "DOWN 100MM" moves the focus in the other direction -5. [ ] "Focus Distance" and "Focus Speed" impacts "⩓" in one direction -6. [ ] "Focus Distance" and "Focus Speed" impacts "⩔" in the other direction -7. [ ] "STOP FOCUS" stops movement - - +1. [ ] "500 μm" + "Near" moves the stage towards the camera +2. [ ] "500 μm" + "Far" moves the stage away from the camera +3. [ ] "Stop" stops movement **Pump** -1. [ ] The left arrow pumps in one direction -2. [ ] The right arrow pumps in the other direction -3. [ ] "Flowrate" and "Volume to pass" impacts speed in one direction -4. [ ] "Flowrate" and "Volume to pass" impacts speed in the other direction -5. [ ] "STOP PUMP" stops the pump +1. [ ] "Backward" pumps in the direction of the camera +2. [ ] "Forward" pumps in the opposite direction of the camera +3. [ ] "Flowrate" impacts "Backward" speed +4. [ ] "Flowrate" impacts "Forward" speed +5. [ ] "Volume" impacts "Backward" duration +6. [ ] "Volume" impacts "Forward" duration +7. [ ] "Stop" stops the pump - +**Bubbler** + +1. Connect tube, needle and plunge in a glass of water +2. [ ] `25%` generates slow bubbles +3. [ ] `50%` generates bubbles faster than `25%` +4. [ ] `75%` generates bubbles faster than `55%` +4. [ ] `100%` generates bubbles faster than `75%` +5. [ ] `Off` stops the bubbler **Prepare** @@ -129,26 +127,27 @@ Setup focus in "Optic Configuration" 5. Import the zip and wait for completion 6. [ ] The result on Ecotaxa matches expectations -## System Monitoring - -1. "Metrics" are coherent -2. "Information" is correct - ## Administration -1. [ ] Logs can be viewed and downloaded -2. [ ] "Restart Hardware Controller" button is working -3. [ ] "Restart Segmenter" button is working -4. [ ] "Reboot" button is working -5. [ ] "Shutdown" button is working +1. [ ] "Reboot" button is working +2. [ ] "Shutdown" button is working ## Network Replace `{machine-name}` with your PlanktoScope name. +### Direct Ethernet + +1. Connect the USB <-> RJ45 cable (USB on your computer, RJ45 on the PlanktoScope) +2. Enable connection sharing on your computer +3. [ ] The PlanktoScope displays an IP address different than `192.168.4.1` (v3 only) +4. [ ] PlanktoScope is accessible at [http:///](http:///) +5. [ ] The preview works correctly + ### Direct WiFi -1. Connect your computer to the PlanktoScope WiFi hotspot +1. [ ] The WiFi network "PlanktoScope {machine-name}" is visible +2. [ ] You can connect your computer to the PlanktoScope WiFi hotspot 2. PlanktoScope is accessible at 1. [ ] [http://planktoscope.local](http://planktoscope.local) 2. [ ] [http://192.168.4.1/](http://192.168.4.1/) @@ -157,8 +156,11 @@ Replace `{machine-name}` with your PlanktoScope name. ### LAN Ethernet 1. Connect the PlanktoScope to your router ethernet -2. PlanktoScope is accessible at - 1. [ ] [http://planktoscope-{machine-name}.local](http://planktoscope-{machine-name}.local) +2. [ ] The PlanktoScope displays an IP address different than `192.168.4.1` (v3 only) +3. [ ] PlanktoScope is accessible at [http:///](http:///) +4. [ ] Preview works correctly +5. [ ] PlanktoScope is accessible at [http://planktoscope-{machine-name}.local](http://planktoscope-{machine-name}.local) +6. [ ] Preview works correctly ## Additional tests