OpenTest chart time terminology

These terms distinguish the capture instant, a position within a measurement, and the visible range. Other domain boundaries are documented in CONTEXT.md.

Time

Acquisition Timestamp: A trustworthy time marker for the instant data was captured, corresponding to a complete calendar date and time. A file's creation or modification date is not an acquisition timestamp. Avoid: File time, accumulated measurement seconds

Task-relative Time: A position relative to the origin of one measurement task, without a calendar date. Avoid: Acquisition timestamp, clock label

Time-axis Display Mode: The representation of a time position presented to the user, including relative seconds and clock time with milliseconds. Avoid: Acquisition time source, fixed-range binding mode

Chart Viewport: The currently visible range of the chart axes. It does not itself determine which points are copied or exported. Avoid: Original data range, export data range

Absolute Fixed Range: A range bounded by two complete acquisition instants. Changing records or measuring again does not change those instants. Avoid: Fixed seconds after the start of each measurement