Monitoring and alerts

This page covers what radvd and the entrypoint log, how to check what reaches the LAN, and the alert rules. The image ships log alert rules, because radvd has no metrics page and reports a fault only in its log. Only another host can see whether advertisements reach the LAN. Checking advertisements continuously shows a monitor that alerts when they stop.

What you get

You run You get You set up
Prometheus, Mimir or VictoriaMetrics, with Alertmanager (the monitoring guide's starting stack adds Loki) The four log rules, only with Loki added. With the setup here, an alert when advertisements stop reaching the LAN, and the forwarding state A CoreRAD monitor on another LAN host with the example rule, and node_exporter with its sysctl collector
Loki and Alertmanager, no metric store All four alert rules A log collector for the container, and alerts/logql.yaml loaded into Loki's ruler
Docker or Unraid only The restart policy, docker logs, and rdisc6 by hand Nothing

Logs

radvd has no metrics endpoint, and its state is in its logs. The entrypoint writes structured level=... msg="..." lines to standard error, and radvd writes its own lines there unchanged. docker logs radvd shows both.

At the default RADVD_DEBUG_LEVEL=0, radvd logs <iface> received RS or RA on <iface> but <iface> is not ready and setup_iface failed whenever a solicitation or advertisement arrives on an interface it never finished bringing up. That is the expected steady state on an HA BACKUP node, where the MASTER's own advertisements trigger it. On a single node it means radvd is not advertising. There, router solicitations from LAN hosts raise the line, but only when this node advertises a default route and the host forwards IPv6. Nothing in the line tells those cases apart, which is why no rule below matches it. Set RADVD_DEBUG_LEVEL=5 for the cause, no configured AdvRASrcAddress present, skipping send.

When radvd sets an interface up with IgnoreIfMissing on and the interface is missing, it logs ignoring the interface (setup_iface=...). That is a normal HA BACKUP state, not an alert, and radvd logs it at debug level 4, so at level 0 it does not appear at all. It carries no not found: line either, because radvd prints that only when the device is absent.

Checking what reaches the LAN

The image ships radvd's own advertisement decoder. docker exec radvd radvdump reads the advertisements that other routers put on the segment, so run it on the peer node to confirm the BACKUP stays silent. It does not show this container's own advertisements. radvd turns off IPv6 multicast loopback on the socket it sends from, so the kernel never hands them back to a local listener. On a single node radvdump therefore stays empty however well radvd works.

For this node's own output, run a probe that listens on the LAN segment from another host:

# On any IPv6 host on the LAN:
sudo rdisc6 eth0

An advertisement from your radvd source address within a few seconds means it works.

Checking advertisements continuously

Consider CoreRAD's monitor mode on another LAN host if you want an alert when advertisements stop reaching the segment. In that mode CoreRAD sends nothing. It counts each router advertisement it receives and serves the counts as Prometheus metrics. Run it on a host that does not run radvd, with this corerad.toml:

[[interfaces]]
name = "eth0"
monitor = true

[debug]
address = ":9430"
prometheus = true

Scrape port 9430 at /metrics. The series corerad_monitor_messages_received_total counts advertisements by host, the sender's link-local address. This rule fires when no advertisement from one sender reached the monitor in 30 minutes. CoreRAD creates the series only when an advertisement arrives, so after a monitor restart it is missing until the next one. The uptime guard and absent_over_time keep that restart from paging. The rule also fires from a new monitor's first start until the first advertisement reaches it:

groups:
  - name: radvd-wire
    rules:
      - alert: RadvdAdvertisementsMissing
        expr: |
          increase(corerad_monitor_messages_received_total{message="router advertisement", host="fe80::1"}[30m]) == 0
            and on(instance, job) (time() - process_start_time_seconds) > 1800
          or absent_over_time(corerad_monitor_messages_received_total{message="router advertisement", host="fe80::1"}[30m])
        for: 0m
        labels:
          severity: warning
        annotations:
          summary: "No router advertisement from fe80::1 reached the LAN in 30 minutes"
          description: >
            The CoreRAD monitor received no advertisement from this router. radvd
            may have stopped, its host may be down, radvd may run but send
            nothing, or the monitor itself is down. Check the container and the
            interface, then confirm with `rdisc6`.

Replace fe80::1 with your node's link-local source address. On a pair of nodes, use the shared AdvRASrcAddress, so the rule follows whichever node advertises. Keep the window at three times your MaxRtrAdvInterval or more, and the uptime guard at the same length in seconds. radvd's default of 600 seconds gives 30 minutes.

For the forwarding state, start node_exporter with --collector.sysctl --collector.sysctl.include=net.ipv6.conf.all.forwarding. It reports node_sysctl_net_ipv6_conf_all_forwarding, which reads 0 while forwarding is off. A rule on it reports the same fault as RadvdForwardingDisabled, so keep one of the two.

Alerting

Load the rules in alerts/logql.yaml into Loki's ruler, as Loading an app's alert rules shows. They cover:

Alert Fires when Severity
RadvdConfigError radvd or the entrypoint rejects the config or a reload, or a peer advertises from a non-link-local address warning
RadvdAdvertisementsUnverified the entrypoint cannot read the mounted radvd.conf, so nothing confirms advertisements are sent warning
RadvdForwardingDisabled radvd advertises a default route while IPv6 forwarding is off on the host warning
RadvdSupervisorFault the entrypoint cannot stop radvd, or radvd exits unexpectedly warning

radvd's lines arrive only on a config error or an event, with no periodic heartbeat, so the rules are fault rules only. A crash stops the container within a second, before the healthcheck runs. The RadvdSupervisorFault exit line and your restart policy report it, and a container that stays stopped reports nothing.

Every pattern is a string radvd or the entrypoint emits, checked against radvd's source at the pinned version. properly \(setup_iface= is anchored on the opening parenthesis so it matches only the fatal form, not the normal ignoring the interface (setup_iface= form above. The parameter-bound fragments are radvd's wording at the pinned version, so a reword in a later release narrows a rule silently. That costs a missed alert, never a false one.

RadvdConfigError

When the fault is present at startup, radvd exits and the entrypoint propagates the exit. Router advertisements stop until the config is fixed. A docker restart starts again from the same file, so the container restarts in a loop.

When a later edit arrives through a SIGHUP reload, the entrypoint checks the file first and refuses the reload. The running radvd keeps its last good config and keeps advertising. Each refusal logs SIGHUP reload refused. For all but one cause that is a rejected edit to fix, not an outage. The remaining cause is a TERM to radvd whose delivery the entrypoint could not confirm, usually in a container without the KILL capability.

The pattern also matches other faults that are not a radvd.conf parse error:

  • The entrypoint's own fatal startup errors, an invalid RADVD_DEBUG_LEVEL and a radvd.conf that is not a regular file. Both stop the container before radvd starts.
  • unable to drop root privileges, which means the container lacks the SETUID and SETGID capabilities.
  • A peer on this segment that sends an advertisement from a non-link-local address. Every host discards those, and radvd names the sender and keeps running. Fix the sending node's AdvRASrcAddress.

Two groups pass the reload check because radvd tests them only after parsing. One is the interface's presence. The other is the parameter bounds, such as the interval bounds, AdvDefaultLifetime and MTU. With IgnoreIfMissing off the container restarts in a loop. With it on, which is radvd's default, radvd stays running and healthy. This alert is then the only sign that the segment has no advertisement sender, and the not found: alternative names that case.

RadvdAdvertisementsUnverified

The entrypoint reads the mounted config within a 5s bound. This alert fires when that read times out or fails outright. radvd then either runs or exits on the same file. When it runs, pidof radvd reports healthy, although radvd's own open of the same file has no bound. When it exits, RadvdConfigError fires beside this warning and the container restarts in a loop. Check what reaches the LAN with rdisc6.

RadvdForwardingDisabled

radvd reads /proc/sys/net/ipv6/conf/all/forwarding and warns when the value is neither 1 nor 2. It also warns when a per-interface forwarding value is below 1. It keeps advertising this node with its configured AdvDefaultLifetime, so LAN hosts can install a default route through a kernel that will not forward their traffic. pidof radvd reports healthy throughout. Fix the sysctl on the host. Under host networking, compose cannot set it.

radvd logs the global warning once per process, so this alert clears after the window even if the state persists. It logs the per-interface warning each time it sets an interface up, at startup, on reload and on a netlink change event. So neither line guarantees a firing alert. A node that sets AdvDefaultLifetime 0 to advertise prefixes only matches this rule legitimately. Confirm with rdisc6 and the host sysctl rather than from the alert alone. node_exporter's sysctl collector reports the state continuously, as Checking advertisements continuously shows.

RadvdSupervisorFault

The entrypoint reports a fault of its own, for one of two causes.

A refused TERM means the container lacks the KILL capability. docker stop then leaves radvd running while the entrypoint exits 0. The final zero-lifetime advertisement is never sent, and LAN hosts keep this node as their default router until the advertised lifetime expires. The container's own exit status is 0, so no restart policy reports this. Grant KILL.

An exit propagation means radvd is gone and advertisements have stopped. The status field carries radvd's own exit status. Your restart policy decides whether the container returns, so a repeating record is a restart loop. For a config fault, radvd's own line matches RadvdConfigError too, and that is the one to read first. This rule covers an exit whose cause radvd words differently, such as an out-of-memory kill reported as status="137".

Adapting the rules

Thresholds and the severity labels are starting points. Change the container selector to the label your log collector sets. The rules group by container, so each container alerts on its own. For a pair of nodes, add the label your collector sets for the host, as in sum by (container, host), so each node alerts on its own.

Knowing the app is alive

radvd opens no port, so nothing outside the container can probe it. Watch Docker health, and watch the LAN for its advertisements.

What healthy means. The container is healthy while a radvd process runs. A radvd that runs but sends nothing stays healthy too. That covers a BACKUP node by design, an interface that never came up, and a config whose interface radvd ignores.

Docker health. The image checks itself every 30 seconds with pidof radvd. Docker marks the container unhealthy after 3 failures, and allows 15 seconds after a start. A crash stops the container within a second, before the healthcheck runs, so your restart policy reacts to it rather than Docker health. Docker's health status notifies nobody on its own, and Docker does not restart an unhealthy container.

Who is told.

You run radvd crashes The container stays stopped, or the host is down radvd runs but sends nothing
Loki with this image's rules RadvdSupervisorFault, from the exit line Nobody, because a stopped container logs nothing Nobody, unless radvd logged a config fault
The monitoring guide's container rules ContainerRestarting, once restarts repeat. It can miss radvd exiting within a second of each start, as on a config fault. RadvdConfigError reports that on Loki Nobody Nobody
A CoreRAD monitor with the example rule RadvdAdvertisementsMissing, if no restart brings advertisements back within the window RadvdAdvertisementsMissing RadvdAdvertisementsMissing
Docker or Unraid only The restart policy restarts it, and nobody is told Nobody Nobody

Only a monitor on the wire sees a radvd that runs but sends nothing.