Needs pyserial: pip install "./python[monitor]" from a checkout (tan-cli is not on PyPI), or pip install pyserial. A bare editable install lacks it, and tan monitor then refuses with that same hint (monitor.pyserial-missing).
--capture records the console headlessly (no terminal needed, works over
rfc2217:// and socket:// URLs). Two option groups let a bench session act
on the console while it records.
tan monitor --port rfc2217://gw:4001 --capture --duration 20 --log run.log \
--send v --send m --send-on 'Press a key'
tan monitor --port rfc2217://gw:4001 --baud 115200 --capture --duration 60 --log wake.log \
--reopen-at 23040 --on 'entering STOP'A malformed --port URL (rfc2217://host: with an empty port, a missing host, a non-numeric or out-of-range port, an unknown scheme) is refused up front as monitor.bad-port (exit 2); local device paths are not judged. Only pyserial's built-in URL schemes are accepted (rfc2217://, socket://, loop://, spy://, alt://, hwgrep://, cp2110://); rfc2217:// and socket:// need HOST:PORT.
-
--send TEXT(repeatable) queues console input. Escapes\xNN,\r,\n,\tand\\are allowed; no newline is added, so single-key knobs (v,m,l,s) go out as exactly that one byte. -
All
--senditems leave as one ordered burst,--send-gap SECONDSapart (default 0.2). The burst goes out at the start of the capture, or:--send-after SECONDSsends it that long after the capture starts, or--send-on REGEXsends it when the first line (or unterminated partial line, e.g. a prompt) matching the regex arrives.
The two are mutually exclusive; a second burst needs a second run.
-
A write that fails or stalls (bounded to 1 s on
rfc2217://) ismonitor.capture-send-failed(exit 1). -
There is no interactive tee mode: the interactive console (no
--capture) already sends keystrokes, but it cannot log to a file.
--reopen-at BAUD --on REGEX changes the baud on the first COMPLETE line
matching REGEX (an unterminated partial line never triggers it), then keeps
capturing into the same --log. The change is made in place (port.baudrate,
supported by local serial and pyserial's rfc2217://), so the link is never
closed and nothing is lost to a reopen gap. Only if the in-place change raises
does it close the port and reopen it, retrying 5 times 200 ms apart; on that
fallback, bytes the device sends while the port is closed are lost. The partial
line and the rest of the read that held the match are dropped, so old-baud
garbage cannot join the first new line or match --until. The
use case is an app UART that comes up at about 23040 instead of 115200 after a
low-power wake. A failed baud change is monitor.capture-reopen-failed (exit 1); --send-on
still matches partial lines (prompts).
It happens at most once per run. Bytes the old baud delivered after the matching
line are not recovered. Events say method: in-place or reopen.
When any of these options is given, data.capture.actions is added:
events ({action: "send", atSeconds, items, bytes} and
{action: "reopen", atSeconds, baud, matchedLine}), sendsPending (0 once
sent) and reopenPending (true when the pattern never matched). All of the
options need --capture; a bad combination is monitor.capture-bad-option
(exit 2).