tan monitor --capture: input and baud change (tan-cli#1451)

Needs pyserial: pip install "./python[monitor]" from a checkout (tan-cli is not on PyPI), or pip install pyserial. A bare editable install lacks it, and tan monitor then refuses with that same hint (monitor.pyserial-missing).

--capture records the console headlessly (no terminal needed, works over rfc2217:// and socket:// URLs). Two option groups let a bench session act on the console while it records.

tan monitor --port rfc2217://gw:4001 --capture --duration 20 --log run.log \
  --send v --send m --send-on 'Press a key'
tan monitor --port rfc2217://gw:4001 --baud 115200 --capture --duration 60 --log wake.log \
  --reopen-at 23040 --on 'entering STOP'

A malformed --port URL (rfc2217://host: with an empty port, a missing host, a non-numeric or out-of-range port, an unknown scheme) is refused up front as monitor.bad-port (exit 2); local device paths are not judged. Only pyserial's built-in URL schemes are accepted (rfc2217://, socket://, loop://, spy://, alt://, hwgrep://, cp2110://); rfc2217:// and socket:// need HOST:PORT.

Sending input

  • --send TEXT (repeatable) queues console input. Escapes \xNN, \r, \n, \t and \\ are allowed; no newline is added, so single-key knobs (v, m, l, s) go out as exactly that one byte.

  • All --send items leave as one ordered burst, --send-gap SECONDS apart (default 0.2). The burst goes out at the start of the capture, or:

    • --send-after SECONDS sends it that long after the capture starts, or
    • --send-on REGEX sends it when the first line (or unterminated partial line, e.g. a prompt) matching the regex arrives.

    The two are mutually exclusive; a second burst needs a second run.

  • A write that fails or stalls (bounded to 1 s on rfc2217://) is monitor.capture-send-failed (exit 1).

  • There is no interactive tee mode: the interactive console (no --capture) already sends keystrokes, but it cannot log to a file.

Changing baud mid-capture

--reopen-at BAUD --on REGEX changes the baud on the first COMPLETE line matching REGEX (an unterminated partial line never triggers it), then keeps capturing into the same --log. The change is made in place (port.baudrate, supported by local serial and pyserial's rfc2217://), so the link is never closed and nothing is lost to a reopen gap. Only if the in-place change raises does it close the port and reopen it, retrying 5 times 200 ms apart; on that fallback, bytes the device sends while the port is closed are lost. The partial line and the rest of the read that held the match are dropped, so old-baud garbage cannot join the first new line or match --until. The use case is an app UART that comes up at about 23040 instead of 115200 after a low-power wake. A failed baud change is monitor.capture-reopen-failed (exit 1); --send-on still matches partial lines (prompts). It happens at most once per run. Bytes the old baud delivered after the matching line are not recovered. Events say method: in-place or reopen.

Envelope

When any of these options is given, data.capture.actions is added: events ({action: "send", atSeconds, items, bytes} and {action: "reopen", atSeconds, baud, matchedLine}), sendsPending (0 once sent) and reopenPending (true when the pattern never matched). All of the options need --capture; a bad combination is monitor.capture-bad-option (exit 2).