Limitations

Aethermor is an architecture-stage reduced-order model, not a product sign-off tool.

The five most important limitations are:

  1. Cross-code evidence exists, but no matched Grade-A hardware holdout does; no hardware accuracy band is claimed.
  2. Package solids are represented by resistance/spreading correlations and a face impedance, not a detailed 3-D package mesh.
  3. Fluid flow, radiation, phase change, boiling, and thermo-mechanical stress are outside the model.
  4. The stable material set is only one near-300 K bulk-silicon profile. Legacy materials are opt-in provisional constants and cannot support release claims.
  5. The solver assumes an orthogonal Cartesian mesh and diagonal conductivity; small features such as bumps, TSVs, interconnects, and local interfaces need homogenization or a higher-fidelity tool.

Additional limitations:

  • the effective HotSpot protocol has disclosed post-output amendments, including corrected benchmark power accounting and comparator-layer mapping, so the final rerun is externally challenged but not a clean preregistration;

  • the native EV6 and accelerator package cases have large Class-B peak-rise disagreements; absolute temperature/headroom magnitude does not transfer;

  • HotSpot's detailed 128-grid comparison is computationally expensive;

  • no temperature-dependent electrothermal leakage iteration;

  • no general off-diagonal conductivity tensor;

  • spreading correlations have geometry/applicability limits;

  • JEDEC theta and psi metrics require matched standard test conditions and are not interchangeable with a generic network resistance;

  • the legacy evolutionary/morphogenesis simulation was removed from the thermal product and remains recoverable from Git history;

  • gate-energy, roadmap, legacy optimizer, and design-space modules are compatibility/experimental conveniences outside the engineering-review surface;

  • the dashboard is a compatibility surface and does not expose all steady-solver metadata, package variables, and uncertainty controls.

Use detailed FEA/CFD and physical characterization for sign-off. Use Aethermor to screen architecture choices, expose binding thermal constraints, and decide which higher-fidelity studies are worth running.