--- ./shutdown 2012-06-30 23:27:34.000000000 +1000
+++ ./shutdown.new 2012-06-30 23:27:21.000000000 +1000
@@ -79,6 +79,10 @@
for vm in session.xenapi.host.get_resident_VMs(host):
record = session.xenapi.VM.get_record(vm)
if not(record["is_control_domain"]) and record["power_state"] == "Running":
+ if record['other_config'].has_key('auto_poweroff') and record['other_config'].get('auto_poweroff') == "false":
+ print "\n Skip running VM %s has self-managed power-off" % record["name_label"],
+ sys.stdout.flush()
+ continue
vms.append((vm,record))
return vms
@@ -173,11 +177,28 @@
vms = []
for vm in session.xenapi.host.get_vms_which_prevent_evacuation(host).keys():
r = session.xenapi.VM.get_record(vm)
+
+ # check for self-managed power off
+ if r['other_config'].has_key('auto_poweroff') and r['other_config'].get('auto_poweroff') == "false":
+ print "\n VM %s has self-managed power-off" % r["name_label"],
+ sys.stdout.flush()
+ continue
+
print "\n VM %s cannot be evacuated" % r["name_label"],
sys.stdout.flush()
vms.append((vm, r))
rc = rc + parallel_clean_shutdown(session, vms)
- vms = filter(lambda (vm, _): session.xenapi.VM.get_power_state(vm) == "Running", vms)
+ vms_f = filter(lambda (vm, _): session.xenapi.VM.get_power_state(vm) == "Running", vms)
+
+ # check for self-managed power off
+ vms = []
+ for (vm,record) in vms_f:
+ if record['other_config'].has_key('auto_poweroff') and record['other_config'].get('auto_poweroff') == "false":
+ print "\n VM %s has self-managed power-off" % record["name_label"],
+ sys.stdout.flush()
+ continue
+ vms.append((vm, r))
+
rc = rc + serial_hard_shutdown(session, vms)
# VMs which can be evacuated should be evacuated